Synthetic Systems

4 papers · 23 extracted observations · system identification · Markdown · CSV · JSON API

Also indexed as: synthetic-systems

Showing 2 of 2 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2015SPe-FIR-RN (reweighted nuclear norm, FIR, SPARSEVA-PEC) proposedaverage computational time145.88 ssplit: val · noise=white · systems=50 · regularization=reweighted nuclear norm (SPARSEVA-PEC) · model-structure=FIRReweighted nuclear norm regularization: A SPARSEVA approach**This work was partially supported by the Swedish Research Council and the Linnaeus Center ACCESS at KTH.
Source quote
L309: \multicolumn{1}{|l|}{251.12} │ 12.88 │ 145.88 │ 1.14
2015CV-FIR-N (nuclear norm, FIR, cross-validation) baselineaverage computational time251.12 ssplit: val · noise=white · systems=50 · regularization=nuclear norm (cross-validation) · model-structure=FIRReweighted nuclear norm regularization: A SPARSEVA approach**This work was partially supported by the Swedish Research Council and the Linnaeus Center ACCESS at KTH.
Source quote
L309: \multicolumn{1}{|l|}{251.12} │ 12.88 │ 145.88 │ 1.14