Stanford Bunny
22 papers · 55 extracted observations · point cloud registration · Markdown · CSV · JSON API
Also indexed as: stanford-bunny
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Reported absolute scores on this metric; fine-grained training or inference settings can differ.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | EKBC (eikonal boundary condition) SOTA frontier | 0.00105 | 2025-04-01 | final-time=T=2 · mesh-level=M=1 · Mesh level M=1; final time T=2. Error compares the final level-set function with the … | Eikonal Boundary Condition for Level Set MethodSource quote\multirow{2}{*}{\ref{TB}} │ 1 │ 1.05E-03 │ 5.1957 │ 1.52E-02 │ 0.1196 │ 1.50E-02 │ -0.0021 |
| 2 | Proposed variational method (Cartesian-depth perspective SfS) SOTA frontier | 0.03235 | 2016-01-01 | n=10^6 · tau=10^-5 · alpha=1.0 · noise=Gaussian σ=20 · Synthetic input with Gaussian noise (σ=20); α=1.0, τ=10^-5, n=10^6. RSE is the normal… | Direct Variational Perspective Shape from Shading with Cartesian Depth ParametrisationSource quoteNoisy Stanford Bunny │ 0.10973 │ 0.17347 │ 0.03235 │ 0.15279 │ \\[-2mm] |
| 3 | Robust orbitope optimization (ℓ1-regularized) SOTA frontier | 0.7825 | 2014-01-01 | noise=zero-mean Gaussian, δ=0.01 · outliers=ears with y ≥ 0.6 translated by (2,2,2) · regularization=ℓ1 · Normalized model with zero-mean Gaussian noise (δ=0.01); points on the ears with y ≥ … | Convex relaxations of SE(2) and SE(3) for visual pose estimationSource quotewas e=0.7825 while that of PCA was e=25.3098. For these noise levels, the error of the orbitope optimization is typical (Figure \ref{ls_vary_noise}) for the case where there are no outliers, indicating the shifting of the ears has only marginal impact on the solution. Indeed, it is possible to make this gap |
Splittest (12)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2019 | Proposed multi-view uncalibrated photometric-stereo variational approach proposed non-standard slice | RMSE | 0.022 arbitrary units | n-images=20 · tau-tilde=10 | Inferring Super-Resolution Depth from a Moving Light-Source Enhanced RGB-D Sensor: A Variational ApproachSource quoteL327: RMSE │ 0.028 │ 0.028 │ 0.114 │ 0.044 │ 0.022 |
| 2011 | Proposed multi-view reconstruction method (six-camera, six-projector setup) proposed | RMSE of reconstructed shapes | 0.0023 | data=synthetic · cameras=6 · projectors=6 · bunny-height=0.1 | Multiview projectors/cameras system for 3D reconstruction of dynamic scenesSource quoteL198: From the figures, we can see that most of the parts are successfully recovered with all the methods. Since the number of the camera is just six, several parts, especially for occluded areas, are wrongly reconstructed with MVS. Comparing to the previous method, there remain many noises by wrong curve detection and large holes for occluded areas, whereas those problems are solved in our method. RMSE of reconstructed shapes are 0.0023, 0.0112 and 0.0089 for our method, MVS and previous method [4], respectively (the height of the bunny was scaled to be 0.1). |