Real dataset

32 papers · 89 extracted observations · novel view synthesis · Markdown · CSV · JSON API

Also indexed as: real-dataset

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.20.50.71.0202020222025Cycle CNN (Ours; full model): 0.954 (2020)NeurIllum: 0.228 (2021)DOF-GS: 0.7667 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023Voxel2Hemodynamics (proposed method) proposedfractional flow reserve (FFR) average error2.5%Average error as reported in the abstract; no further evaluation protocol is specified …Voxel2Hemodynamics: An End-to-end Deep Learning Method for Predicting Coronary Artery Hemodynamics
Source quote
L7: Local hemodynamic forces play an important role in determining the functional significance of coronary arterial stenosis and understanding the mechanism of coronary disease progression. Computational fluid dynamics (CFD) have been widely performed to simulate hemodynamics non-invasively from coronary computed tomography angiography (CCTA) images. However, accurate computational analysis is still limited by the complex construction of patient-specific modeling and time-consuming computation. In this work, we proposed an end-to-end deep learning framework, which could predict the coronary artery hemodynamics from CCTA images. The model was trained on the hemodynamic data obtained from 3D simulations of synthetic and real datasets. Extensive experiments demonstrated that the predicted hemdynamic distributions by our method agreed well with the CFD-derived results. Quantitatively, the proposed method has the capability of predicting the fractional flow reserve with an average error of 0.5% and 2.5% for the synthetic dataset and real dataset, respectively. Particularly, our method achieved much better accuracy for the real dataset compared to PointNet++ with the point cloud input. This study demonstrates the feasibility and great potential of our end-to-end deep learning method as a fast and accurate approach for hemodynamic analysis.
2022TEG-Track(BundleTrack) [TE(BT)] proposedR_err (mean rotation error)2.5input=RGB-DEnhancing Generalizable 6D Pose Tracking of an In-Hand Object with Tactile Sensing
Source quote
L276: R-err\downarrow │ 5.3 │ 4.0 │ 3.9 │ 17.8 │ 7.1 │ 3.9 │ 2.5
2022TEG-Track(BundleTrack) [TE(BT)] proposedT_err (mean translation error)1.8input=RGB-DEnhancing Generalizable 6D Pose Tracking of an In-Hand Object with Tactile Sensing
Source quote
L277: T-err\downarrow │ 4.1 │ 3.3 │ 3.2 │ 15.3 │ 10.6 │ 2.4 │ 1.8
2021ActiveZero (mixed domain learning; table label “Ours”) proposedAbs depth err (All)4.377 mmsplit: testActiveZero: Mixed Domain Learning for Active Stereovision with Zero Annotation
Source quote
L163: Ours │ 0.314 │ 0.028 │ 4.377 │ 6.584 │ 14.694 │ 0.335 │ 0.437 │ 0.725
2017Fine-tuning proposed non-standard slicemean absolute error on the HDR sky (EHDR)2.55split: test · fine-tuned · input=real JPG panoramasLearning High Dynamic Range from Outdoor Panoramas
Source quote
L208: 2.55