Real Data
43 papers · 102 extracted observations · 3d hand pose estimation · vision · Markdown · CSV · JSON API
Also indexed as: real-data
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | IRON (Our) SOTA frontier | 0.1091 | 2022-04-01 | lighting=co-located flashlight · evaluation=novel views · split-ratio=70% train / 30% test · object-captures=5 · Real captures use a 70% training / 30% test split; test images evaluate generalizatio… | IRON: Inverse Rendering by Optimizing Neural SDFs and Materials from Photometric ImagesSource quoteOur │ 0.1091 │ 0.8614 │ 29.3694 |
| 2 | FLARE | 0.1225 | 2023-10-01 | evaluation-region=masked-face · test-time-optimization=none · Test-set frames; evaluation on masked face regions. FLARE is not test-time optimized;… | FLARE: Fast Learning of Animatable and Relightable Mesh AvatarsSource quoteOurs │ 0.0245 │ 0.1225 │ 0.8421 │ 24.7845 |
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | LEADS proposed | Test mean activation time error | 5.52 | split: test · subgroups=AP, RM, MS | Learning Cardiac Electrophysiology Digital Twins Through Agentic Discovery of Hybrid StructureSource quoteL116: LEADS (Ours) │ \multicolumn{3}{c}{5.52} |
| 2026 | Hybrid-Model baseline | Test mean activation time error | 5.64 | split: test · subgroup=AP | Learning Cardiac Electrophysiology Digital Twins Through Agentic Discovery of Hybrid StructureSource quoteL113: Hybrid-Model~\cite{jiang2024hyper} │ 5.64 │ 6.62 │ 7.48 |
| 2025 | 7-point and 8+-point solvers (interleaved measurements) proposed | Translation error | 3.46% | split: test · imagery=static · measurement-pattern=interleaved measurements from two scanlines · scanline-separation=400 rows | Camera Resection from Known Line Pencils and a Radially Distorted ScanlineSource quoteL755: 3.46%. However, this test is sensitive to the choice of interleaving. Next, we evaluate the 8+-point solver using all of the measurements from the same two scanlines of the previous test (see Figure 5c). Orientation error is 3.49 de- |
| 2020 | Conditional LRCN friction estimator, trained with reflective-substrate renderings proposed | Real test data within absolute error < 0.1 of the reference measurement interval | 93.6% | split: test · training-data=simulated plus reflective-substrate renderings · substrate-coverage=all substrates | Learning to Measure the Static Friction Coefficient in Cloth ContactSource quoteL216: After adding reflective substrate renderings, we obtain an error of < 0.1 for 93.6% of real test data on all substrates, as shown in the green curve of Fig. 6. Note that adding the variation to the training data improves the results overall, yielding better results than training and testing without reflective materials (black curve). The supplemental material provides a more detailed analysis of these results. |
| 2020 | Conditional LRCN friction estimator, trained without reflective-substrate renderings ablation | Real test data within absolute error < 0.1 of the reference measurement interval | 61.9% | split: test · training-data=without reflective-substrate renderings · substrate-coverage=all substrates | Learning to Measure the Static Friction Coefficient in Cloth ContactSource quoteL212: On real data, our model achieves an error of < 0.1 on 61.9% of data on all substrates (see red curve of Fig. 6). Our test data includes silk, for which no similar material is present in the simulated training data, and our method achieves an error of < 0.1 of over |
| 2020 | Conditional LRCN friction estimator, trained without reflective-substrate renderings ablation | Real test data within absolute error < 0.1 of the reference measurement interval | 86.1% | split: test · training-data=without reflective-substrate renderings · evaluation-subset=excluding reflective substrates | Learning to Measure the Static Friction Coefficient in Cloth ContactSource quoteL213: 60%. The decay in model accuracy compared to simulated test data can be mostly attributed to the presence of reflecting substrates in the real data, a factor that is not modelled in our training data. The light blue curve of Fig. 6 shows that the model accuracy is significantly worse on substrates which are reflective. Removing these substrates from the evaluation yields a error of < 0.1 for 86.1% of data, as |