PURE

33 papers · 58 extracted observations · heart rate estimation · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Heart Rate Estimation.

-0.11.63.24.920242025TS-CAN (trained on MAUBFC-rPPG): 1.14 (2024)TS-CAN (trained on UBFC-rPPG): 4.55 (2024)ME-rPPG: 0.25 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 14 of 14 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025CiCi proposedMAE4.96Heart Rate Estimation · split: test · test-time-adaptation · training=HSRD-trained on other four datasetsNot Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological Measurement
Source quote
L197: CiCi │ 3.55\(^*\) │ 6.27\(^*\) │ 0.89 │ 4.96\(^*\) │ 7.99\(^*\) │ 0.90\(^*\) │ 1.49\(^*\) │ 1.96\(^*\) │ 0.99 │ 6.87\(^*\) │ 10.59\(^*\) │ 0.64\(^*\) │ 8.58\(^*\) │ 11.03\(^*\) │ 0.54\(^*\)
2025Semi-rPPG proposedRMSE1.01 BPMHeart Rate Estimation · split: test · semi-supervised · source-dataset=UBFC-rPPG · unlabeled-data=COHFACESemi-rPPG: Semi-Supervised Remote Physiological Measurement With Curriculum Pseudo-Labeling
Source quote
L300: Semi-rPPG (Ours) │ UBFC-rPPG+ │ PURE │ 0.57 │ 1.01 │ 0.99 │ 0.99 │ COHFACE(un)
2024RhythmMamba proposedMAE0.23Heart Rate Estimation · split: test · intra-datasetRhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement
Source quote
L246: We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE dataset, we followed the protocols outlined in \cite{dualgan}, splitting the dataset sequentially into training and testing sets with a ratio of 6:4. Similarly, for the evaluation of the UBFC dataset, we followed the protocols in \cite{dualgan}, selecting the first 30 samples as the training set and the remaining 12 samples as the testing set. Due to the absence of the validation set, we selected the checkpoint from the last epoch for testing and compared them with the reported results from previous methods. As shown in Table \ref{tab:intra}, on the PURE dataset, our method outperformed all state-of-the-art methods across all metrics, achieving the minimum MAE (0.23) and RMSE (0.34). On the UBFC dataset, our method also achieved comparable performance to others.
2024RhythmMamba proposedRMSE0.34Heart Rate Estimation · split: test · intra-datasetRhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement
Source quote
L246: We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE dataset, we followed the protocols outlined in \cite{dualgan}, splitting the dataset sequentially into training and testing sets with a ratio of 6:4. Similarly, for the evaluation of the UBFC dataset, we followed the protocols in \cite{dualgan}, selecting the first 30 samples as the training set and the remaining 12 samples as the testing set. Due to the absence of the validation set, we selected the checkpoint from the last epoch for testing and compared them with the reported results from previous methods. As shown in Table \ref{tab:intra}, on the PURE dataset, our method outperformed all state-of-the-art methods across all metrics, achieving the minimum MAE (0.23) and RMSE (0.34). On the UBFC dataset, our method also achieved comparable performance to others.
2024PhysMamba proposedMAE5.32Heart Rate Estimation · split: test · evaluation=cross-dataset · training-dataset=MMPDPhysMamba: State Space Duality Model for Remote Physiological Measurement
Source quote
L200: PhysMamba(Ours) │ 5.32 │ 12.98 │ 9.56 │ 0.84
2024UP-Phys proposedMAE0.48Heart Rate Estimation · split: test · fine-tunedUP-Phys: Exploring the Effect of Prior Knowledge in Unsupervised Remote Photoplethysmography
Source quote
L137: 0.18 and 0.48 MAE accuracy on UBFC-rPPG and PURE datasets, respectively. It significantly outperforms SiNC [14] by 0.41 and 0.13 on these two datasets. Note that while our UP-Phys is based on Contrast-Phys [13], it significantly outperforms Contrast-Phys. This success is attributed to the pivotal role of prior knowledge and UP-Phys’s keen ability to focus on regions abundant in rPPG information, simultaneously demonstrating the effectiveness of our proposed method.
2023Proposed method (eight selected augmentation operations) proposedMAE2.256Heart Rate Estimation · split: test · model=TSCAN · augmentation=eight selected operations · training-data=SCAMPSTraining Robust Deep Physiological Measurement Models with Synthetic Video-based Data
Source quote
L237: PURE │ 2.256 │ 9.435 │ 2.380 │ 0.919
2023NEST proposedHR MAE↓7.6889 bpmHeart Rate Estimation · split: test · evaluation=MSDG · training-datasets=UBFC, BUAA, VIPL, V4VNeuron Structure Modeling for Generalizable Remote Physiological Measurement
Source quote
L202: NEST │ 0.0635 │ 0.0874 │ 0.6422 │ 0.0635 │ 0.0874 │ 0.6422 │ 0.2255 │ 0.3505 │ 0.5734 │ 7.6889 │ 10.4783 │ 0.7255
2022Ours + TALOS proposedRMSE2.30 BPMHeart Rate Estimation · split: testEfficient Remote Photoplethysmography with Temporal Derivative Modules and Time-Shift Invariant Loss
Source quote
L324: 2.30
2022ErPPG estimator (Ours (All)) proposedMAE0.38Heart Rate Estimation · split: testAugmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos
Source quote
L334: 0.38
2022ErPPG estimator (Ours (All)) proposedRMSE0.54Heart Rate Estimation · split: testAugmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos
Source quote
L335: 0.54
2022ErPPG estimator (Ours (All)) proposedPearson correlation coefficient (R)0.96Heart Rate Estimation · split: testAugmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos
Source quote
L336: 0.96
2021Dual-GAN proposedMAE↓0.82Heart Rate Estimation · split: testDual-GAN: Joint BVP and Noise Modeling for Remote Physiological Measurement
Source quote
L332: 0.82
2018HR-CNN proposedRMSE2.37Heart Rate Estimation · split: test · split=authors-defined · training=database-specific · test_videos=24 · test_subjects=4Visual Heart Rate Estimation with Convolutional Neural Network
Source quote
L276: 2.37 1