PURE
33 papers · 58 extracted observations · heart rate estimation · Markdown · CSV · JSON API
Tasks on PUREAll tasks (33)Heart Rate Estimation (30)Pulse Rate Estimation (1)Remote Photoplethysmography (1)Requirements Conflict Detection (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Heart Rate Estimation.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ME-rPPG SOTA frontier | 0.25 Beats/Min | 2025-04-01 | Cross-dataset evaluation; source training dataset is not specified in the cited resul… | Memory-efficient Low-latency Remote Photoplethysmography through Temporal-Spatial State Space DualitySource quoteCross-dataset Experiments. To assess the generalization ability of our method, we evaluate its performance in cross-dataset settings. The results in Table~\ref{tab:cross} indicate that ME-rPPG achieves the best performance across most cross-dataset settings, demonstrating strong generalization. Specifically, ME-rPPG achieves the lowest MAE of 5.38 and the highest R of 0.78 on the challenging MMPD dataset when trained on the RLAP dataset. Additionally, ME-rPPG outperforms all methods on the largest VitalVideo dataset (MAE: 0.70, R: 0.98) and the PURE dataset (MAE: 0.25, R: 1.00), confirming its robustness and reliability. Compared to intra-dataset results, ME-rPPG maintains consistent performance across different datasets, whereas other methods show significant performance drops. This demonstrates our method's effectiveness in handling diverse real-world scenarios and generalizing well across datasets. |
| 2 | TS-CAN (trained on MAUBFC-rPPG) SOTA frontier (+1 variant) | 1.14 Beats/Min | 2024-01-01 | Inter-dataset evaluation; trained on UBFC-rPPG augmented with motion and tested on PU… | Motion Matters: Neural Motion Transfer for Better Camera Physiological MeasurementSource quoteMAUBFC-rPPG │ TS-CAN │ 1.14 │ 5.95 │ 1.30 │ 0.97 │ 3.93 │ 7.50 │ 5.24 │ 0.81 │ 2.67 │ 6.55 │ 3.65 │ 0.85 │ 6.80 │ 14.20 │ 7.97 │ 0.29 |
Other primary task on PURE: Heart Rate Estimation · MAE ↓ (bpm) · test (2 papers)
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | PRISM (Enhanced) SOTA frontier | 0.77 bpm | 2025-11-01 | window=10-second · windowing=non-overlapping · configuration=enhanced rPPG-Toolbox · Enhanced rPPG-Toolbox configuration; non-overlapping 10-second windows, 2^14 FFT bins… | Adaptive Parameter Optimization for Robust Remote PhotoplethysmographySource quotePRISM │ 2.66 │ 0.77 │ 3.10 │ 0.66 |
| 2 | NEST SOTA frontier | 7.6889 bpm | 2023-03-01 | evaluation=MSDG · training-datasets=UBFC, BUAA, VIPL, V4V · MSDG: train on the other four datasets (UBFC, BUAA, VIPL, V4V) and test on PURE. | Neuron Structure Modeling for Generalizable Remote Physiological MeasurementSource quoteNEST │ 0.0635 │ 0.0874 │ 0.6422 │ 0.0635 │ 0.0874 │ 0.6422 │ 0.2255 │ 0.3505 │ 0.5734 │ 7.6889 │ 10.4783 │ 0.7255 |
TaskHeart Rate Estimation (54)Remote Photoplethysmography (2)Pulse Rate Estimation (1)Requirements Conflict Detection (1)
Regimesupervised (4)fine-tuned (3)semi-supervised (2)intra-dataset (2)0-shot (2)test-time-adaptation (1)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | RhythmMamba proposed | MAE | 0.23 | Heart Rate Estimation · split: test · intra-dataset | RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological MeasurementSource quoteL246: We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE dataset, we followed the protocols outlined in \cite{dualgan}, splitting the dataset sequentially into training and testing sets with a ratio of 6:4. Similarly, for the evaluation of the UBFC dataset, we followed the protocols in \cite{dualgan}, selecting the first 30 samples as the training set and the remaining 12 samples as the testing set. Due to the absence of the validation set, we selected the checkpoint from the last epoch for testing and compared them with the reported results from previous methods. As shown in Table \ref{tab:intra}, on the PURE dataset, our method outperformed all state-of-the-art methods across all metrics, achieving the minimum MAE (0.23) and RMSE (0.34). On the UBFC dataset, our method also achieved comparable performance to others. |
| 2024 | RhythmMamba proposed | RMSE | 0.34 | Heart Rate Estimation · split: test · intra-dataset | RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological MeasurementSource quoteL246: We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE dataset, we followed the protocols outlined in \cite{dualgan}, splitting the dataset sequentially into training and testing sets with a ratio of 6:4. Similarly, for the evaluation of the UBFC dataset, we followed the protocols in \cite{dualgan}, selecting the first 30 samples as the training set and the remaining 12 samples as the testing set. Due to the absence of the validation set, we selected the checkpoint from the last epoch for testing and compared them with the reported results from previous methods. As shown in Table \ref{tab:intra}, on the PURE dataset, our method outperformed all state-of-the-art methods across all metrics, achieving the minimum MAE (0.23) and RMSE (0.34). On the UBFC dataset, our method also achieved comparable performance to others. |