PURE

33 papers · 58 extracted observations · heart rate estimation · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Heart Rate Estimation.

-0.11.63.24.920242025TS-CAN (trained on MAUBFC-rPPG): 1.14 (2024)TS-CAN (trained on UBFC-rPPG): 4.55 (2024)ME-rPPG: 0.25 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MVRD-rPPG proposed non-standard sliceMAE0.77Remote Photoplethysmography · 0-shot · fine-tuning=none · training-data=MVRD Movement subsetMVRD-Bench: Multi-View Learning and Benchmarking for Dynamic Remote Photoplethysmography under Occlusion
Source quote
L306: Our Method │ 0.77 │ 1.00 │ 0.99 │ 0.83 │ 1.73 │ 0.98 │ 0.69 │ 0.81 │ 0.99
2025CiCi proposedMAE4.96Heart Rate Estimation · split: test · test-time-adaptation · training=HSRD-trained on other four datasetsNot Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological Measurement
Source quote
L197: CiCi │ 3.55\(^*\) │ 6.27\(^*\) │ 0.89 │ 4.96\(^*\) │ 7.99\(^*\) │ 0.90\(^*\) │ 1.49\(^*\) │ 1.96\(^*\) │ 0.99 │ 6.87\(^*\) │ 10.59\(^*\) │ 0.64\(^*\) │ 8.58\(^*\) │ 11.03\(^*\) │ 0.54\(^*\)
2025FactorizePhys with TSFM (Target Signal constraint) proposedMAE0.30Heart Rate Estimation · constraint=Target Signal · source-dataset=UBFC-rPPG · attention-block=NMFEfficient and Robust Multidimensional Attention in Remote Physiological Sensing through Target Signal Constrained Factorization
Source quote
L248: 0.30
2025FedHUG + SiNC proposedMAE↓5.76Heart Rate EstimationFedHUG: Federated Heterogeneous Unsupervised Generalization for Remote Physiological Measurements
Source quote
L448: FedHUG + SiNC │ 6.73 │ 8.90 │ 9.06 │ 0.55 │ 5.76 │ 7.80 │ 8.08 │ 0.69 │ 3.52 │ 6.69 │ 4.77 │ 0.85 │ 9.73 │ 11.64 │ 11.87 │ 0.16
2025PRISM (Enhanced) proposedMAE0.77 bpmHeart Rate Estimation · window=10-second · windowing=non-overlapping · configuration=enhanced rPPG-ToolboxAdaptive Parameter Optimization for Robust Remote Photoplethysmography
Source quote
L292: PRISM │ 2.66 │ 0.77 │ 3.10 │ 0.66
2024RhythmMamba proposedMAE0.23Heart Rate Estimation · split: test · intra-datasetRhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement
Source quote
L246: We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE dataset, we followed the protocols outlined in \cite{dualgan}, splitting the dataset sequentially into training and testing sets with a ratio of 6:4. Similarly, for the evaluation of the UBFC dataset, we followed the protocols in \cite{dualgan}, selecting the first 30 samples as the training set and the remaining 12 samples as the testing set. Due to the absence of the validation set, we selected the checkpoint from the last epoch for testing and compared them with the reported results from previous methods. As shown in Table \ref{tab:intra}, on the PURE dataset, our method outperformed all state-of-the-art methods across all metrics, achieving the minimum MAE (0.23) and RMSE (0.34). On the UBFC dataset, our method also achieved comparable performance to others.
2024MAR-rPPG proposedMAE0.08Heart Rate EstimationToward Motion Robustness: A masked attention regularization framework in remote photoplethysmography
Source quote
L138: We observe that our proposed MAR-rPPG method outperforms all compared methods across all evaluated metrics. Notably, it achieves a MAE of 0.08 and a RSME of
2024DOHA+ (DOHA applied to Baseline [CAN]) proposedMAE1.03Heart Rate Estimation · evaluation=unseen-domain · train-domain=UBFCResolve Domain Conflicts for Generalizable Remote Physiological Measurement
Source quote
L465: DOHA^+ │ 7.68 │ 12.69 │ 0.60 │ 1.03 │ 1.39 │ 0.97 [1.5pt]
2024TN-Net proposedMAE0.622Heart Rate Estimation · training-dataset=MMPDA Plug-and-Play Temporal Normalization Module for Robust Remote Photoplethysmography
Source quote
L293: The TN module can improve training performance on complex, high-noise real-world datasets. MMPD \cite{tang2023mmpd}, recognized as a challenging dataset for real-world validation, is difficult to train on due to significant video compression and motion noise. Most previous research either failed to train on the full MMPD dataset \cite{Liu2024SpikingPhysFormerCR} or opted to train on a subset\cite{Zhao_2024_CVPR}. In contrast, our TN module enables all methods to successfully train on the entire MMPD dataset in Table \ref{resultmmpd}, with performance gains ranging from 34.3% to 98.8%. Moreover, it helps achieve clinical-level accuracy (MAE below 2) in cross-dataset experiments: 1.114 with TN-Net on RLAP, 2.042 with PhysNet-TN on COHFACE, 0.622 with TN-Net on PURE, and 0.519 with TSCAN-TN on UBFC.
2024PhysMamba proposedMAE5.32Heart Rate Estimation · split: test · evaluation=cross-dataset · training-dataset=MMPDPhysMamba: State Space Duality Model for Remote Physiological Measurement
Source quote
L200: PhysMamba(Ours) │ 5.32 │ 12.98 │ 9.56 │ 0.84
2024UP-Phys proposedMAE0.48Heart Rate Estimation · split: test · fine-tunedUP-Phys: Exploring the Effect of Prior Knowledge in Unsupervised Remote Photoplethysmography
Source quote
L137: 0.18 and 0.48 MAE accuracy on UBFC-rPPG and PURE datasets, respectively. It significantly outperforms SiNC [14] by 0.41 and 0.13 on these two datasets. Note that while our UP-Phys is based on Contrast-Phys [13], it significantly outperforms Contrast-Phys. This success is attributed to the pivotal role of prior knowledge and UP-Phys’s keen ability to focus on regions abundant in rPPG information, simultaneously demonstrating the effectiveness of our proposed method.
2024Bi-TTA proposedM↓ (MAE)5.02Heart Rate Estimation · fps=30 FPSBi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement
Source quote
L233: Ours │ \textbf{{7.09}} │ \textbf{{10.72}} │ \textbf{{0.63}} │ 9.1 │ 11.02 │ 0.54 │ \textbf{{5.02}} │ \textbf{{8.11}} │ \textbf{{0.890}} │ 3.53 │ 6.24 │ 0.891 │ \textbf{{1.49}} │ \textbf{{1.97}} │ \textbf{{0.99}}
2023Proposed method (eight selected augmentation operations) proposedMAE2.256Heart Rate Estimation · split: test · model=TSCAN · augmentation=eight selected operations · training-data=SCAMPSTraining Robust Deep Physiological Measurement Models with Synthetic Video-based Data
Source quote
L237: PURE │ 2.256 │ 9.435 │ 2.380 │ 0.919
2023NEST proposedHR MAE↓7.6889 bpmHeart Rate Estimation · split: test · evaluation=MSDG · training-datasets=UBFC, BUAA, VIPL, V4VNeuron Structure Modeling for Generalizable Remote Physiological Measurement
Source quote
L202: NEST │ 0.0635 │ 0.0874 │ 0.6422 │ 0.0635 │ 0.0874 │ 0.6422 │ 0.2255 │ 0.3505 │ 0.5734 │ 7.6889 │ 10.4783 │ 0.7255
2023RoI+Sh+B (U) proposedMAE0.96Heart Rate Estimation · method=RoI extraction, shuffling, blurring · key-selection=unbounded randomizedPrivacy-Preserving Remote Heart Rate Estimation from Facial Videos
Source quote
L188: Ours │ 0.96 │ 1.30 │ 0.99 │ 0.89 │ 1.24 │ 0.99
2023Self-supervised (Encoder A / 3D, shuffle augmentation) proposedMAE0.74Heart Rate Estimation · self-supervised-pretraining · roi=full · encoder=3D · augmentation=shuffle · video-encoding=MPEG-4Remote Heart Rate Monitoring in Smart Environments From Videos With Self-Supervised Pretraining
Source quote
L411: In Tables \ref{allenc}, \ref{cheekenc}, and \ref{forenc}, we compare the effect of using different video encoding methods by experimenting with 3D and (2+1)D convolutions. Encoder A refers to the encoder using 3D convolution while Encoder B refers to the encoder using (2+1)D convolutions. In the case of the fully-supervised baselines for all three instances of the RoI, using (2+1)D convolutions gives comparable results to the 3D counterpart. However, among the results obtained after self-supervised pre-training and fine-tuning, the best results across all three metrics were obtained for the 3D convolution-based encoder. Since rPPG estimation relies on very slight changes in skin color, the additional non-linearities brought along with using (2+1)D convolution might interfere with the training process rather than help in some cases. This can be seen especially in the case of PURE (MPEG-4) in Table \ref{cheekenc} wherein the error values obtained using Encoder B in the self-supervised approach are nearly double the values obtained using Encoder A. Moreover, in the case of COHFACE in Table \ref{forenc}, using Encoder B did not give any improvement in terms of MAE when using the self-supervised approach. Nevertheless, there is substantial improvement shown by the self-supervised approach over the supervised approach for both the encoders. For COHFACE, compared to the fully supervised learning baseline for Encoder A, the self-supervised learning approach using the flip augmentation, reduces MAE from 2.62 to 2.16, and RMSE from 4.59 to 3.61, while increasing R from 0.90 to 0.94. For PURE (MPEG-4), compared to the fully supervised learning baseline, the self-supervised learning approach using the shuffle augmentation, reduces MAE from 0.97 to 0.74 and RMSE from 1.20 to 0.93. Likewise, for COHFACE, compared to the fully supervised learning baseline for Encoder B, the self-supervised learning approach using the rotation augmentation, reduces MAE from 2.68 to 2.14 and RMSE from 4.42 to 3.61, while increasing R from 0.90 to 0.94. For PURE (MPEG-4), compared to the fully supervised learning baseline, the self-supervised learning approach using the reverse augmentation, reduces MAE from 1.06 to 0.72 and RMSE from 1.52 to 1.02. We observe similar improvements when using the cheek and the forehead as separate RoIs in Tables \ref{cheekenc} and \ref{forenc}, except in the setting with using the forehead as the RoI along with Encoder B for COHFACE where the MAE are very similar.
2022ErPPG estimator (Ours (All)) proposedMAE0.38Heart Rate Estimation · split: testAugmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos
Source quote
L334: 0.38
2021Dual-GAN proposedMAE↓0.82Heart Rate Estimation · split: testDual-GAN: Joint BVP and Noise Modeling for Remote Physiological Measurement
Source quote
L332: 0.82