- **Tasks Evaluated**: Heart Rate Estimation (`?task=heart-rate-estimation`, 30 papers), Pulse Rate Estimation (`?task=pulse-rate-estimation`, 1 papers), Remote Photoplethysmography (`?task=remote-photoplethysmography`, 1 papers), Requirements Conflict Detection (`?task=requirements-conflict-detection`, 1 papers)

## Comparable Cohort Leaderboards

### Heart Rate Estimation · MAE ↓ (Beats/Min) (2 papers)

| # | Method | Score | Year | Settings | Paper |
| ---: | --- | ---: | --- | --- | --- |
| 1 | ME-rPPG | 0.25 Beats/Min | 2025-04-01 | - | [Memory-efficient Low-latency Remote Photoplethysmography through Temporal-Spatial State Space Duality](/work/memory-efficient-low-latency-remote-photoplethysmography) |
| 2 | TS-CAN (trained on MAUBFC-rPPG) | 1.14 Beats/Min | 2024-01-01 | - | [Motion Matters: Neural Motion Transfer for Better Camera Physiological Measurement](/work/motion-matters-neural-motion-transfer-for-better-camera-85e6) |

### Heart Rate Estimation · MAE ↓ (bpm) · test (2 papers)

| # | Method | Score | Year | Settings | Paper |
| ---: | --- | ---: | --- | --- | --- |
| 1 | PRISM (Enhanced) | 0.77 bpm | 2025-11-01 | window=10-second, windowing=non-overlapping, configuration=enhanced rPPG-Toolbox | [Adaptive Parameter Optimization for Robust Remote Photoplethysmography](/work/adaptive-parameter-optimization-for-robust-remote) |
| 2 | NEST | 7.6889 bpm | 2023-03-01 | evaluation=MSDG, training-datasets=UBFC, BUAA, VIPL, V4V | [Neuron Structure Modeling for Generalizable Remote Physiological Measurement](/work/neuron-structure-modeling-for-generalizable-remote) |

## Recent Extracted Observations

| Year | Method | Role | Metric | Score | Split | Regime | Paper | Verbatim Quote |
| --- | --- | --- | --- | ---: | --- | --- | --- | --- |
| 2025 | CiCi | proposed | MAE | 4.96 | test | test-time-adaptation | [Not Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological Measurement](/work/not-only-consistency-enhance-test-time-adaptation) | CiCi & 3.55\(^*\) & 6.27\(^*\) & 0.89 & 4.96\(^*\) & 7.99\(^*\) & 0.90\(^*\) & 1.49\(^*\) & 1.96\(^*\) & 0.99 & 6.87\(^*\) & 10.59\(^*\) & 0.64\(^*\) & 8.58\(^* |
| 2025 | Semi-rPPG | proposed | RMSE | 1.01 BPM | test | semi-supervised | [Semi-rPPG: Semi-Supervised Remote Physiological Measurement With Curriculum Pseudo-Labeling](/work/semi-rppg-semi-supervised-remote-physiological-measurement) | &Semi-rPPG (Ours) & UBFC-rPPG+ & PURE & 0.57 & 1.01 & 0.99 & 0.99 & &COHFACE(un) & & & & & |
| 2025 | FactorizePhys with TSFM (Target Signal constraint) | proposed | MAE | 0.30 | - | - | [Efficient and Robust Multidimensional Attention in Remote Physiological Sensing through Target Signal Constrained Factorization](/work/efficient-and-robust-multidimensional-attention-in-remote) | 0.30 & |
| 2025 | FedHUG + SiNC | proposed | MAE↓ | 5.76 | - | - | [FedHUG: Federated Heterogeneous Unsupervised Generalization for Remote Physiological Measurements](/work/fedhug-federated-heterogeneous-unsupervised-generalization) | FedHUG + SiNC & 6.73 & 8.90 & 9.06 & 0.55 & 5.76 & 7.80 & 8.08 & 0.69 & 3.52 & 6.69 & 4.77 & 0.85 & 9.73 & 11.64 & 11.87 & 0.16 |
| 2025 | PRISM (Enhanced) | proposed | MAE | 0.77 bpm | - | - | [Adaptive Parameter Optimization for Robust Remote Photoplethysmography](/work/adaptive-parameter-optimization-for-robust-remote) | & PRISM & 2.66 & 0.77 & 3.10 & 0.66 |
| 2025 | PRISM | proposed | Accuracy within ±5 bpm | 97.3% % | - | - | [Adaptive Parameter Optimization for Robust Remote Photoplethysmography](/work/adaptive-parameter-optimization-for-robust-remote) | The accuracy results further demonstrate PRISM's effectiveness, achieving 97.3% accuracy on PURE and 97.5% accuracy on UBFC-rPPG, outperforming all other unsupe |
| 2025 | PhysDiff | proposed | RMSE↓ | 0.54 | - | - | [PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement](/work/physdiff-physiology-based-dynamicity-disentangled-diffusion) | 0.54 |
| 2025 | PhysDiff | proposed | RMSE↓ | 6.89 bpm | - | - | [PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement](/work/physdiff-physiology-based-dynamicity-disentangled-diffusion) | 6.89 |
| 2025 | FactorizePhys (NMF attention block, None constraint) | ablation | MAE | 0.48 | - | - | [Efficient and Robust Multidimensional Attention in Remote Physiological Sensing through Target Signal Constrained Factorization](/work/efficient-and-robust-multidimensional-attention-in-remote) | 0.48 & |
| 2025 | TYrPPG (CSL; Loss_c + Loss_t + Loss_h) | ablation | MAE | 9.25 | test | - | [TYrPPG: Uncomplicated and Enhanced Learning Capability rPPG for Remote Heart Rate Estimation](/work/tyrppg-uncomplicated-and-enhanced-learning-capability-rppg) | Loss_c + Loss_t + Loss_h (CSL) & 9.25 & 11.51 & 0.41 |
| 2025 | TYrPPG (CSL; Loss_c + Loss_t + Loss_h) | ablation | RMSE | 11.51 | test | - | [TYrPPG: Uncomplicated and Enhanced Learning Capability rPPG for Remote Heart Rate Estimation](/work/tyrppg-uncomplicated-and-enhanced-learning-capability-rppg) | Loss_c + Loss_t + Loss_h (CSL) & 9.25 & 11.51 & 0.41 |
| 2025 | TYrPPG (WSL; Loss_h + Loss_t) | ablation | MAE | 11.60 | test | - | [TYrPPG: Uncomplicated and Enhanced Learning Capability rPPG for Remote Heart Rate Estimation](/work/tyrppg-uncomplicated-and-enhanced-learning-capability-rppg) | Loss_h + Loss_t (WSL) & 11.60 & 15.57 & 0.04 |
| 2025 | TYrPPG (WSL; Loss_h + Loss_t) | ablation | RMSE | 15.57 | test | - | [TYrPPG: Uncomplicated and Enhanced Learning Capability rPPG for Remote Heart Rate Estimation](/work/tyrppg-uncomplicated-and-enhanced-learning-capability-rppg) | Loss_h + Loss_t (WSL) & 11.60 & 15.57 & 0.04 |
| 2025 | ME-rPPG | unclear | MAE (HR estimation) | 0.25 Beats/Min | - | - | [Memory-efficient Low-latency Remote Photoplethysmography through Temporal-Spatial State Space Duality](/work/memory-efficient-low-latency-remote-photoplethysmography) | Cross-dataset Experiments. To assess the generalization ability of our method, we evaluate its performance in cross-dataset settings. The results in Table~\ref{ |
| 2025 | SSL-Self-training | baseline | RMSE | 2.24 BPM | test | semi-supervised | [Semi-rPPG: Semi-Supervised Remote Physiological Measurement With Curriculum Pseudo-Labeling](/work/semi-rppg-semi-supervised-remote-physiological-measurement) | &SSL-Self-training~\cite{amini2022self} & UBFC-rPPG+ & PURE & 0.91 & 2.24 & 0.95 & 2.22 & & COHFACE(un) & & & & & |
| 2025 | POS (Enhanced) | baseline | MAE | 2.23 bpm | - | - | [Adaptive Parameter Optimization for Robust Remote Photoplethysmography](/work/adaptive-parameter-optimization-for-robust-remote) | & POS \cite{pos} & 3.67 & 2.23 & 4.00 & 1.08 |
| 2024 | RhythmMamba | proposed | MAE | 0.23 | test | intra-dataset | [RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement](/work/rhythmmamba-fast-lightweight-and-accurate-remote) | We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE datase |
| 2024 | RhythmMamba | proposed | RMSE | 0.34 | test | intra-dataset | [RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement](/work/rhythmmamba-fast-lightweight-and-accurate-remote) | We conducted intra-dataset evaluation on the PURE and UBFC datasets to validate the feasibility of the Mamba architecture. For the evaluation of the PURE datase |
| 2024 | MAR-rPPG | proposed | MAE | 0.08 | - | - | [Toward Motion Robustness: A masked attention regularization framework in remote photoplethysmography](/work/toward-motion-robustness-a-masked-attention-regularization) | We observe that our proposed MAR-rPPG method outperforms all compared methods across all evaluated metrics. Notably, it achieves a MAE of 0.08 and a RSME of |
| 2024 | DOHA+ (DOHA applied to Baseline [CAN]) | proposed | MAE | 1.03 | - | - | [Resolve Domain Conflicts for Generalizable Remote Physiological Measurement](/work/resolve-domain-conflicts-for-generalizable-remote) | DOHA^+ & & 7.68 & 12.69 & 0.60 & & 1.03 & 1.39 & 0.97 [1.5pt] |
| 2024 | TN-Net | proposed | MAE | 0.622 | - | - | [A Plug-and-Play Temporal Normalization Module for Robust Remote Photoplethysmography](/work/a-plug-and-play-temporal-normalization-module) | The TN module can improve training performance on complex, high-noise real-world datasets. MMPD \cite{tang2023mmpd}, recognized as a challenging dataset for rea |
| 2024 | PhysMamba | proposed | MAE | 5.32 | test | - | [PhysMamba: State Space Duality Model for Remote Physiological Measurement](/work/physmamba-state-space-duality-model-for-remote-physiological) | PhysMamba(Ours) & & 5.32 & 12.98 & 9.56 & 0.84 |
| 2024 | UP-Phys | proposed | MAE | 0.48 | test | fine-tuned | [UP-Phys: Exploring the Effect of Prior Knowledge in Unsupervised Remote Photoplethysmography](/work/up-phys-exploring-the-effect-of-prior-knowledge) | 0.18 and 0.48 MAE accuracy on UBFC-rPPG and PURE datasets, respectively. It significantly outperforms SiNC [14] by 0.41 and 0.13 on these two datasets. Note tha |
| 2024 | Bi-TTA | proposed | M↓ (MAE) | 5.02 | - | - | [Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement](/work/bi-tta-bidirectional-test-time-adapter-for-remote) | Ours & \textbf{{7.09}}& \textbf{{10.72}}&\textbf{{0.63}}&9.1&11.02&0.54& \textbf{{5.02}} &\textbf{{8.11}}& \textbf{{0.890}}&3.53& 6.24&0.891& \textbf{{1.49}}&\t |
| 2024 | PhysNet + FWD loss | ablation | MAE | 1.06 bpm | test | supervised | [SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency](/work/sfda-rppg-source-free-domain-adaptive-remote-physiological-cn2m) | & UBFC & 0.58 & 1.22 & 0.99 & 1.06 & 2.93 & 0.97 |
| 2024 | AdaODM | unclear | M↓ (MAE) | 5.51 | - | - | [Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement](/work/bi-tta-bidirectional-test-time-adapter-for-remote) | AdaODM \cite{zhang2023adaptive} & 7.81& 11.21& 0.55&9.1& 10.93& 0.55&5.51& 8.29& 0.88&4.01& 6.59& 0.87&1.91& 2.6& 0.95 |
| 2024 | DualGAN | baseline | MAE | 0.82 | - | - | [Toward Motion Robustness: A masked attention regularization framework in remote photoplethysmography](/work/toward-motion-robustness-a-masked-attention-regularization) | 0.29, vastly superior than the second-best performer DualGAN on the PURE dataset, which has a MAE of 0.82 and a RMSE of 1.31. Additionally, our method obtains a |
| 2024 | Baseline [CAN] | baseline | MAE | 2.67 | - | - | [Resolve Domain Conflicts for Generalizable Remote Physiological Measurement](/work/resolve-domain-conflicts-for-generalizable-remote) | Baseline\cite{CAN} & & 12.21 & 19.89 & 0.44 & & 2.67 & 7.63 & 0.80 |
| 2024 | PhysFormer | baseline | MAE in HR estimation | 12.92 Beats/Min | test | - | [Spiking-PhysFormer: Camera-based remote photoplethysmography with parallel spike-driven transformer](/work/spiking-physformer-camera-based-remote-photoplethysmography) | PhysFormer & & 12.92 & 23.92 & 0.47 & 6.63 & 8.91 & 0.69 & \uline{12.10} & 15.41 & 0.17 |
| 2024 | RhythmMamba | baseline | MAE | 6.07 | test | - | [PhysMamba: State Space Duality Model for Remote Physiological Measurement](/work/physmamba-state-space-duality-model-for-remote-physiological) | RhythmMamba & & 6.07 & 14.43 & 9.66 & 0.78 |
| 2023 | rPPG-MAE | proposed | MeanAE | 0.40 | - | fine-tuned | [rPPG-MAE: Self-supervised Pre-training with Masked Autoencoders for Remote Physiological Measurement](/work/rppg-mae-self-supervised-pretraining-with-masked) | 0.40 |
| 2023 | Proposed method (eight selected augmentation operations) | proposed | MAE | 2.256 | test | - | [Training Robust Deep Physiological Measurement Models with Synthetic Video-based Data](/work/training-robust-deep-physiological-measurement-models) | PURE & 2.256 & 9.435 &2.380 & 0.919 |
| 2023 | NEST | proposed | HR MAE↓ | 7.6889 bpm | test | - | [Neuron Structure Modeling for Generalizable Remote Physiological Measurement](/work/neuron-structure-modeling-for-generalizable-remote) | & NEST & 0.0635 & 0.0874 & 0.6422 & 0.0635 & 0.0874 & 0.6422 & 0.2255 & 0.3505 & 0.5734 & 7.6889 & 10.4783 & 0.7255 |
| 2023 | RoI+Sh+B (U) | proposed | MAE | 0.96 | - | - | [Privacy-Preserving Remote Heart Rate Estimation from Facial Videos](/work/privacy-preserving-remote-heart-rate-estimation-from-facial) | Ours & 0.96 & 1.30 & 0.99 & 0.89 & 1.24 & 0.99 |
| 2023 | Self-supervised (Encoder A / 3D, shuffle augmentation) | proposed | MAE | 0.74 | - | self-supervised-pretraining | [Remote Heart Rate Monitoring in Smart Environments From Videos With Self-Supervised Pretraining](/work/remote-heart-rate-monitoring-in-smart-environments-etvd) | In Tables \ref{allenc}, \ref{cheekenc}, and \ref{forenc}, we compare the effect of using different video encoding methods by experimenting with 3D and (2+1)D co |
| 2023 | TS-CAN (trained on UBFC-rPPG) | unclear | MAE (heart-rate estimation) | 4.55 Beats/Min | - | - | [Motion Matters: Neural Motion Transfer for Better Camera Physiological Measurement](/work/motion-matters-neural-motion-transfer-for-better-camera-85e6) | & POS & 4.00 & 7.58 & 3.86 & 0.92 & 3.67 & 11.82 & 7.25 & 0.88 & 4.62 & 8.02 & 6.29 & 0.78 & 6.93 & 11.89 & 10.00 & 0.49 & 8.18 & 13.04 & 11.12 & 0.31 UBFC-rPPG |
| 2023 | TS-CAN (trained on MAUBFC-rPPG) | unclear | MAE (heart-rate estimation) | 1.14 Beats/Min | - | - | [Motion Matters: Neural Motion Transfer for Better Camera Physiological Measurement](/work/motion-matters-neural-motion-transfer-for-better-camera-85e6) | MAUBFC-rPPG & TS-CAN & - & - & - & - & 1.14 & 5.95 & 1.30 & 0.97 & 3.93 & 7.50 & 5.24 & 0.81 & 2.67 & 6.55 & 3.65 & 0.85 & 6.80 & 14.20 & 7.97 & 0.29 |
| 2023 | SSPD† (with frame-difference calculation) | baseline | MAE | 0.53 bpm | test | - | [Self-Similarity Prior Distillation for Unsupervised Remote Physiological Measurement](/work/self-similarity-prior-distillation-for-unsupervised-remote) | & SSPD^\bigstar & 0.78M & 84.79 & ×1.00 & 0.53 [1pt] |
| 2023 | Baseline▲ (ImageNet-pretrained ViT encoder) | baseline | MeanAE | 18.79 | - | fine-tuned | [rPPG-MAE: Self-supervised Pre-training with Masked Autoencoders for Remote Physiological Measurement](/work/rppg-mae-self-supervised-pretraining-with-masked) | 18.79 |
| 2023 | No perturbation | baseline | MAE | 0.65 | - | - | [Privacy-Preserving Remote Heart Rate Estimation from Facial Videos](/work/privacy-preserving-remote-heart-rate-estimation-from-facial) | No perturbation & 0.65 & 0.95 & 0.99 & 0.52 & 0.76 & 0.99 |
| 2023 | Fully supervised baseline (Encoder A / 3D) | baseline | MAE | 0.97 | - | fully-supervised | [Remote Heart Rate Monitoring in Smart Environments From Videos With Self-Supervised Pretraining](/work/remote-heart-rate-monitoring-in-smart-environments-etvd) | In Tables \ref{allenc}, \ref{cheekenc}, and \ref{forenc}, we compare the effect of using different video encoding methods by experimenting with 3D and (2+1)D co |
| 2022 | Ours + TALOS | proposed | RMSE | 2.30 BPM | test | - | [Efficient Remote Photoplethysmography with Temporal Derivative Modules and Time-Shift Invariant Loss](/work/efficient-remote-photoplethysmography-with-temporal) | 2.30 |
| 2022 | ErPPG estimator (Ours (All)) | proposed | MAE | 0.38 | test | - | [Augmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos](/work/augmentation-of-rppg-benchmark-datasets-learning-to-remove) | 0.38 |
| 2022 | ErPPG estimator (Ours (All)) | proposed | RMSE | 0.54 | test | - | [Augmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos](/work/augmentation-of-rppg-benchmark-datasets-learning-to-remove) | 0.54 |
| 2022 | ErPPG estimator (Ours (All)) | proposed | Pearson correlation coefficient (R) | 0.96 | test | - | [Augmentation of rPPG Benchmark Datasets: Learning to Remove and Embed rPPG Signals via Double Cycle Consistent Learning from Unpaired Facial Videos](/work/augmentation-of-rppg-benchmark-datasets-learning-to-remove) | 0.96 |
| 2022 | TS-CAN | baseline | MAE | 6.67 Beats/Min | - | supervised | [rPPG-Toolbox: Deep Remote PPG Toolbox](/work/rppg-toolbox-deep-remote-ppg-toolbox) | TS-CAN~\cite{liu2020multi} & 6.86 & 16.1 & 6.68 & 0.76 & 6.67 & 18.9 & 7.93 & 0.62 |
| 2022 | PhysNet | baseline | MAE | 19.95 Beats/Min | - | supervised | [rPPG-Toolbox: Deep Remote PPG Toolbox](/work/rppg-toolbox-deep-remote-ppg-toolbox) | PhysNet~\cite{yu2019remote}& 6.46 & 12.2 & 6.50 & 0.823 & 19.95 & 27.57 & 0.16 & 31.54 |
| 2022 | DeepPhys | baseline | MAE | 3.46 Beats/Min | - | supervised | [rPPG-Toolbox: Deep Remote PPG Toolbox](/work/rppg-toolbox-deep-remote-ppg-toolbox) | DeepPhys~\cite{chen2018deepphys}& 3.83 & 12.5 & 3.62 & 0.82 & 3.46 & 12.9 & 3.53 & 0.84 |
| 2021 | Dual-GAN | proposed | MAE↓ | 0.82 | test | - | [Dual-GAN: Joint BVP and Noise Modeling for Remote Physiological Measurement](/work/dual-gan-joint-bvp-and-noise-modeling) | 0.82 |
| 2021 | HR-CNN [32] | baseline | MAE↓ | 1.84 | test | - | [Dual-GAN: Joint BVP and Noise Modeling for Remote Physiological Measurement](/work/dual-gan-joint-bvp-and-noise-modeling) | 1.84 |
| 2020 | Proposed multi-scale facial-ROI method (proposed g) | proposed | SNR | 13.79 dB | - | - | [Remote Estimation of Heart Rate Based on Multi-Scale Facial ROIs](/work/remote-estimation-of-heart-rate-based) | 13.79 |
| 2020 | Proposed multi-scale facial-ROI method (proposed g) | proposed | SNR | 6.58 dB | - | - | [Remote Estimation of Heart Rate Based on Multi-Scale Facial ROIs](/work/remote-estimation-of-heart-rate-based) | 6.58 |
| 2020 | Proposed multi-scale facial-ROI method (proposed g) | proposed | SNR | 11.09 dB | - | - | [Remote Estimation of Heart Rate Based on Multi-Scale Facial ROIs](/work/remote-estimation-of-heart-rate-based) | 11.09 proposed u |
| 2018 | HR-CNN | proposed | RMSE | 2.37 | test | - | [Visual Heart Rate Estimation with Convolutional Neural Network](/work/visual-heart-rate-estimation-with-convolutional-neural) | 2.37 1 |