Pix3D

56 papers · 160 extracted observations · 3d reconstruction · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=3D Reconstruction.

0.20.30.30.4202020222024Ours (DeepSDF Embedding): 0.302 (2020)Ours (Joint Embedding): 0.325 (2020)3D-NVS: 0.105 (2020)Pix2Vox++: 0.215 (2021)Pix2Vox++: 0.292 (2021)Mem3D: 0.336 (2021)Mem3D: 0.387 (2021)LRGT: 0.299 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026RTMO on Femto Bolt RGB-D stream baselineMean per-joint position error (MPJPE)104mm3D Pose Estimation · model=RTMO · camera=Femto Bolt · mounting-heights=1.8 m, 2.0 m, 2.2 mEvaluation Protocols and Validation for Cameras in Indoor Healthcare Monitoring
Source quote
L338: MPJPE of 104mm and a mean PCK of 85.7%, indicating consistently reliable 3D pose
2026RTMO on ZED2 RGB-D stream baselineMean per-joint position error (MPJPE)345mm3D Pose Estimation · model=RTMO · camera=ZED2 · mounting-heights=1.8 m, 2.0 m, 2.2 mEvaluation Protocols and Validation for Cameras in Indoor Healthcare Monitoring
Source quote
L341: has substantially higher error, with a mean MPJPE of 345mm and a mean PCK of 22.3%.
2026YOLO26 on Femto Bolt RGB-D stream baselineMean per-joint position error (MPJPE)110mm3D Pose Estimation · model=YOLO26 · camera=Femto Bolt · mounting-heights=1.8 m, 2.0 m, 2.2 mEvaluation Protocols and Validation for Cameras in Indoor Healthcare Monitoring
Source quote
L343: 110mm and mean PCK of 83.5%, RealSense at 143mm and 67.9%, and ZED2 at 365mm and 21.8%.
2026YOLO26 on ZED2 RGB-D stream baselineMean per-joint position error (MPJPE)365mm3D Pose Estimation · model=YOLO26 · camera=ZED2 · mounting-heights=1.8 m, 2.0 m, 2.2 mEvaluation Protocols and Validation for Cameras in Indoor Healthcare Monitoring
Source quote
L343: 110mm and mean PCK of 83.5%, RealSense at 143mm and 67.9%, and ZED2 at 365mm and 21.8%.
2023FocalPose++ proposedMedErr-R,t (pose error)0.99Object Pose EstimationFocalPose++: Focal Length and Object Pose Estimation via Render and Compare
Source quote
L421: FocalPose++ (ours) │ 95.5% │ 4.19 │ 85.1% │ 1.31 │ 0.99 │ 1.34 │ 2.34 │ 81.5%
2023FocalPose++ proposed non-standard sliceMedErr_f (relative focal length error)1.34Focal Length EstimationFocalPose++: Focal Length and Object Pose Estimation via Render and Compare
Source quote
L421: FocalPose++ (ours) │ 95.5% │ 4.19 │ 85.1% │ 1.31 │ 0.99 │ 1.34 │ 2.34 │ 81.5%
2022[12]-LF baselineMedErrf (median focal length error)1.72Focal Length EstimationFocal Length and Object Pose Estimation via Render and Compare
Source quote
L241: 1.72
2020Mask Refinement baseline non-standard slicePose error (MedErr-R,t)3.073D Pose Estimation · split: test · model=ground-truth 3D model · scale=×10² · subset=non-occluded, non-truncated · category=bed · statistic=medianGeometric Correspondence Fields: Learned Differentiable Rendering for 3D Pose Refinement in the Wild
Source quote
L396: Mask Refinement~\cite{Kato2018renderer} │ 3.03 │ 4.04 │ 3.07 │ 2.00
2020Mask Refinement baseline non-standard sliceProjection error (MedErr-P)2.003D Pose Estimation · split: test · model=ground-truth 3D model · scale=×10² · subset=non-occluded, non-truncated · category=bed · statistic=medianGeometric Correspondence Fields: Learned Differentiable Rendering for 3D Pose Refinement in the Wild
Source quote
L396: Mask Refinement~\cite{Kato2018renderer} │ 3.03 │ 4.04 │ 3.07 │ 2.00
2019Ours (fine-tuned on real images) proposed non-standard sliceMedian angular pose error0.27 degreesViewpoint Estimation · fine-tuned · category=chairs · fine-tuning-data=real imagesSelf-supervised 3D Shape and Viewpoint Estimation from Single Images for Robotics
Source quote
L269: We learn to predict the shapes and poses of the real-world chairs by fine-tuning our model trained on synthetic images. Despite the large domain gap between synthetic and real images, we achieve a mean IoU of 0.21 and a median angular pose error of 0.27 in this challenging setting. We show qualitative results in Figure~\ref{fig:real}. In this extremely challenging setting, the network learns to produce non-trivial reconstructions that differ significantly from the mean shape.