PhysioNet · Motor Imagery Classification

20 papers · 59 extracted observations · motor imagery classification · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Motor Imagery Classification.

0.80.80.90.92020Proposed robust RNN: 0.9 (2020)Latent-ODE (RNN Encoder): 0.781 (2020)GRU-D: 0.824 (2020)Latent-ODE (ODE Encoder): 0.829 (2020)ODE-RNN: 0.833 (2020)ODE-GRU-D: 0.8947 (2020)Extended ODE-GRU-D: 0.9147 (2020)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 26 of 26 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025DRDCAE-STGNN proposedaverage accuracy95.9%Motor Imagery Classification · classes=2DRDCAE-STGNN: An End-to-End Discrimina-tive Autoencoder with Spatio-Temporal Graph Learning for Motor Imagery Classification
Source quote
L233: 2025 │ DRDCAE-STGNN │ 95.9 │ 0.958 │ 0.917 │ 0.986 │ 2025 │ DRDCAE-STGNN │ 90.2 │ 0.901 │ 0.936 │ 0.868
2025DRDCAE-STGNN proposedaverage accuracy90.2%Motor Imagery Classification · classes=4DRDCAE-STGNN: An End-to-End Discrimina-tive Autoencoder with Spatio-Temporal Graph Learning for Motor Imagery Classification
Source quote
L233: 2025 │ DRDCAE-STGNN │ 95.9 │ 0.958 │ 0.917 │ 0.986 │ 2025 │ DRDCAE-STGNN │ 90.2 │ 0.901 │ 0.936 │ 0.868
2024FGTIRMSE0.580Motor Imagery ClassificationFrequency-aware Generative Models for Multivariate Time Series Imputation
Source quote
L372: 1.006 0.619 0.875 0.652 0.580
2024CSDIRMSE0.619Motor Imagery ClassificationFrequency-aware Generative Models for Multivariate Time Series Imputation
Source quote
L372: 1.006 0.619 0.875 0.652 0.580
2023ST-ImputeRMSE0.702Motor Imagery Classification · split: testFilling out the missing gaps: Time Series Imputation with Semi-Supervised Learning
Source quote
L234: PhysioNet │ 50% │ 0.916 │ 0.917 │ 0.766 │ 0.808 │ 0.787 │ 0.783 │ 0.779 │ 0.714 │ \textcolor{blue}{0.702}
2023TransformerRMSE0.714Motor Imagery Classification · split: testFilling out the missing gaps: Time Series Imputation with Semi-Supervised Learning
Source quote
L234: PhysioNet │ 50% │ 0.916 │ 0.917 │ 0.766 │ 0.808 │ 0.787 │ 0.783 │ 0.779 │ 0.714 │ \textcolor{blue}{0.702}
2022Learning Differential Operators (hybrid PDE with meta-learning controller; Ours) proposedtest RMSE2.3266Motor Imagery Classification · split: testLearning Differential Operators for Interpretable Time Series Modeling
Source quote
L202: 2.3551 │ 2.3291 │ 2.4673 │ 2.3266
2022NIERT proposedaverage MSE (×10^-3)2.868Motor Imagery ClassificationNIERT: Accurate Numerical Interpolation through Unifying Scattered Data Representations using Transformer Encoder
Source quote
L276: Accuracy on PhysioNet dataset: Table \ref{table:PhysioNet} suggests that on the PhysioNet dataset, NIERT also outperforms the existing approaches, e.g., when controlling the ratio of observed points to be 50%, NIERT achieves an average MSE (× 10 (-3)) of 2.868, significantly lower than other approaches. Again, NIERT with the pre-training technique shows better performance. The advantages of NIERT hold across various settings of the ratio of the observed points.
2022Dynamic EEGInception proposedDynamic Avg. Accuracy83.9%Motor Imagery Classification · leave-one-subject-out · epochs=30 · classes=left-vs-right-hand · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L157: 83.9% p-value ≈0.0068
2022Dynamic EEGInception proposedDynamic Avg. Accuracy71.4%Motor Imagery Classification · leave-one-subject-out · epochs=30 · classes=left-hand/right-hand/feet · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L161: 71.4% p-value ≈0.00025
2022Dynamic DeepConvNet proposedDynamic Avg. Accuracy71.3%Motor Imagery Classification · leave-one-subject-out · epochs=30 · classes=left-hand/right-hand/feet · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L145: 71.3% p-value ≈0.0000328
2022Ours (ensemble curriculum learning and collaborative training), K=7 proposedAccuracy86.36%Motor Imagery Classification · split: test · K=7 · evaluation=5-fold subject-level cross-validationMotor Imagery Decoding Using Ensemble Curriculum Learning and Collaborative Training
Source quote
L153: Ours, K=7 │ 15.7K │ 86.36
2022Ours (ensemble curriculum learning and collaborative training), K=7 proposedAccuracy85.82%Motor Imagery Classification · split: test · K=7 · evaluation=leave-one-subject-outMotor Imagery Decoding Using Ensemble Curriculum Learning and Collaborative Training
Source quote
L185: Ours, K=7 │ 15.7K │ 85.82
2022ConvTranstest RMSE2.3291Motor Imagery Classification · split: testLearning Differential Operators for Interpretable Time Series Modeling
Source quote
L202: 2.3551 │ 2.3291 │ 2.4673 │ 2.3266
2022EEGInception (normal network) baselineNormal Avg. Accuracy81.6%Motor Imagery Classification · leave-one-subject-out · epochs=50 · classes=left-vs-right-hand · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L156: 81.6%
2022EEGInception (normal network) baselineNormal Avg. Accuracy67.6%Motor Imagery Classification · leave-one-subject-out · epochs=50 · classes=left-hand/right-hand/feet · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L160: 67.6%
2022DeepConvNet (normal network) baselineNormal Avg. Accuracy67.1%Motor Imagery Classification · leave-one-subject-out · epochs=50 · classes=left-hand/right-hand/feet · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L144: 67.1%
2022EEGNet-Ensemble (8 models) baselineAccuracy84.56%Motor Imagery Classification · split: test · evaluation=5-fold subject-level cross-validation · ensemble-size=8Motor Imagery Decoding Using Ensemble Curriculum Learning and Collaborative Training
Source quote
L148: \textbf{\makecell{EEGNet-Ensemble\\(8 models)}} │ 20.0K │ 84.56
2020Proposed robust RNN proposedMicro-averaged AUC0.90Motor Imagery ClassificationMedi-Care AI: Predicting medications from billing codes via robust recurrent neural networks
Source quote
L219: \parbox[t]{1mm}{\multirow{5}{*}{\rotatebox[origin=c]{90}{RNN}}} │ Ours │ \color{red}0.90 │ \color{red}0.78
2020ODE-GRU-DAUC0.8947Motor Imagery ClassificationNeural ODEs for Informative Missingness in Multivariate Time Series
Source quote
L290: ODE-GRU-D │ 0.8947 │ 0.001
2020Extended ODE-GRU-DAUC0.9147Motor Imagery ClassificationNeural ODEs for Informative Missingness in Multivariate Time Series
Source quote
L291: Extended ODE-GRU-D │ 0.9147 │ 0.005
2020GRU-DAUC0.824Motor Imagery ClassificationNeural ODEs for Informative Missingness in Multivariate Time Series
Source quote
L285: \multicolumn{2}{c}{AUC} GRU-D │ 0.824 │ 0.0.12
2020ODE-RNNAUC0.833Motor Imagery ClassificationNeural ODEs for Informative Missingness in Multivariate Time Series
Source quote
L286: ODE-RNN │ 0.833 │ 0.009
2020Latent-ODE (RNN Encoder)AUC0.781Motor Imagery ClassificationNeural ODEs for Informative Missingness in Multivariate Time Series
Source quote
L287: Latent-ODE (RNN Encoder) │ 0.781 │ 0.018
2020Latent-ODE (ODE Encoder)AUC0.829Motor Imagery ClassificationNeural ODEs for Informative Missingness in Multivariate Time Series
Source quote
L288: Latent-ODE (ODE Encoder) │ 0.829 │ 0.004
2020SRL-RNN baselineMicro-averaged AUC0.86Motor Imagery ClassificationMedi-Care AI: Predicting medications from billing codes via robust recurrent neural networks
Source quote
L224: SRL-RNN \cite{SRL-RNN} │ 0.86 │ 0.74