PhysioNet

20 papers · 59 extracted observations · motor imagery classification · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Motor Imagery Classification.

0.80.80.90.92020Proposed robust RNN: 0.9 (2020)Latent-ODE (RNN Encoder): 0.781 (2020)GRU-D: 0.824 (2020)Latent-ODE (ODE Encoder): 0.829 (2020)ODE-RNN: 0.833 (2020)ODE-GRU-D: 0.8947 (2020)Extended ODE-GRU-D: 0.9147 (2020)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 31 of 31 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026PaX-LIME proposedMean feature attribution0.40Sepsis Prediction · fine-tuned · model=MedGemma · measurement-category=direct sepsis indicatorsInterpreting Sepsis Prediction through Positional Explanation
Source quote
L110: PaX-LIME track clinician judgments of sepsis relevance, with mean attributions of 0.40, 0.31, and 0.22 across direct, partial, and unrelated measurements. We define ∆f as the difference between the PaX-LIME feature component and the standard LIME attribution; a positive value means standard LIME underestimated the measurement because some of its attribution was absorbed by position. We find ∆f > 0 for 24/29 measurements labeled as direct or partial sepsis indicators. Standard LIME dilutes critical biomarkers by conflating them with their temporal placement; PaX-LIME recovers an attribution profile a clinician can read as a statement about the measurement itself.
2026PaX-LIME proposedMean feature attribution0.31Sepsis Prediction · fine-tuned · model=MedGemma · measurement-category=partial sepsis indicatorsInterpreting Sepsis Prediction through Positional Explanation
Source quote
L110: PaX-LIME track clinician judgments of sepsis relevance, with mean attributions of 0.40, 0.31, and 0.22 across direct, partial, and unrelated measurements. We define ∆f as the difference between the PaX-LIME feature component and the standard LIME attribution; a positive value means standard LIME underestimated the measurement because some of its attribution was absorbed by position. We find ∆f > 0 for 24/29 measurements labeled as direct or partial sepsis indicators. Standard LIME dilutes critical biomarkers by conflating them with their temporal placement; PaX-LIME recovers an attribution profile a clinician can read as a statement about the measurement itself.
2026PaX-LIME proposedMean feature attribution0.22Sepsis Prediction · fine-tuned · model=MedGemma · measurement-category=unrelated to sepsisInterpreting Sepsis Prediction through Positional Explanation
Source quote
L110: PaX-LIME track clinician judgments of sepsis relevance, with mean attributions of 0.40, 0.31, and 0.22 across direct, partial, and unrelated measurements. We define ∆f as the difference between the PaX-LIME feature component and the standard LIME attribution; a positive value means standard LIME underestimated the measurement because some of its attribution was absorbed by position. We find ∆f > 0 for 24/29 measurements labeled as direct or partial sepsis indicators. Standard LIME dilutes critical biomarkers by conflating them with their temporal placement; PaX-LIME recovers an attribution profile a clinician can read as a statement about the measurement itself.
2026PaX proposedFeature attribution score0.33Sepsis Prediction · fine-tuned · model=MedGemma · feature=GenderInterpreting Sepsis Prediction through Positional Explanation
Source quote
L116: Gender comparable importance (0.76 and 0.73); once PaX decouples position from feature, Age retains a high feature score (0.77) while Gender drops to 0.33, with the remainder absorbed into the position component. PhysioNet places demographics at admission, so this pattern is consistent with a primacy bias rather than a biological link between gender and sepsis risk. Standard attribution would invite a clinician to act on the apparent link; PaX-LIME flags it as positional and tells the clinician to discount it.
2026MTEEG-DC proposedBalanced Acc.0.5125Eeg Classification · split: test · peft · LoRA rank=8 · partition=64% train, 16% validation, 20% testTowards Unified Multi-task EEG Analysis with Low-Rank Adaptation
Source quote
L188: MTEEG\xspace-DC │ 1.1M │ 0.7024 │ 0.6754 │ 0.7828 │ 0.5125 │ 0.4402 │ 0.6143
2026MTEEG-DC proposedCohen's Kappa0.4402Eeg Classification · split: test · peft · LoRA rank=8 · partition=64% train, 16% validation, 20% testTowards Unified Multi-task EEG Analysis with Low-Rank Adaptation
Source quote
L188: MTEEG\xspace-DC │ 1.1M │ 0.7024 │ 0.6754 │ 0.7828 │ 0.5125 │ 0.4402 │ 0.6143
2026MTEEG-DC proposedWeighted F10.6143Eeg Classification · split: test · peft · LoRA rank=8 · partition=64% train, 16% validation, 20% testTowards Unified Multi-task EEG Analysis with Low-Rank Adaptation
Source quote
L188: MTEEG\xspace-DC │ 1.1M │ 0.7024 │ 0.6754 │ 0.7828 │ 0.5125 │ 0.4402 │ 0.6143
2025DRDCAE-STGNN proposedaverage accuracy95.9%Motor Imagery Classification · classes=2DRDCAE-STGNN: An End-to-End Discrimina-tive Autoencoder with Spatio-Temporal Graph Learning for Motor Imagery Classification
Source quote
L233: 2025 │ DRDCAE-STGNN │ 95.9 │ 0.958 │ 0.917 │ 0.986 │ 2025 │ DRDCAE-STGNN │ 90.2 │ 0.901 │ 0.936 │ 0.868
2025DRDCAE-STGNN proposedaverage accuracy90.2%Motor Imagery Classification · classes=4DRDCAE-STGNN: An End-to-End Discrimina-tive Autoencoder with Spatio-Temporal Graph Learning for Motor Imagery Classification
Source quote
L233: 2025 │ DRDCAE-STGNN │ 95.9 │ 0.958 │ 0.917 │ 0.986 │ 2025 │ DRDCAE-STGNN │ 90.2 │ 0.901 │ 0.936 │ 0.868
2023PrimeNet proposedAUC0.842Mortality Classification · fine-tuned · pretraining=unlabeled-data · training-data=fullPrimeNet: Pre-training for Irregular Multivariate Time Series
Source quote
L253: PrimeNet 0.641 ± 0.071 0.663 ± 0.047 0.681 ± 0.026 0.842 0.595 ± 0.063 0.601 ± 0.06 0.638 ± 0.038 0.838
2023PrimeNet proposedRMSE3.59 ×10−2Time Series Interpolation · training-data=full · observation-rate=50%PrimeNet: Pre-training for Irregular Multivariate Time Series
Source quote
L297: PrimeNet 60.84 ± 21.62 41.56 ± 16.98 25.45 ± 3.28 14.3 11.28 ± 2.91 9.37 ± 2.72 7.85 ± 1.98 3.59
2023CSBI proposedRMSE0.55Time Series Imputation · raw-missingness=80% · target-fraction=10% · evaluation-samples=100Provably Convergent Schrödinger Bridge with Applications to Probabilistic Time Series Imputation
Source quote
L428: \multicolumn{1}{l}{ 0.55} │ \multicolumn{1}{l}{ 0.23 } │ 0.25
2023CSBI proposedRMSE0.63Time Series Imputation · raw-missingness=80% · target-fraction=50% · evaluation-samples=100Provably Convergent Schrödinger Bridge with Applications to Probabilistic Time Series Imputation
Source quote
L429: \multicolumn{1}{l}{ 0.63} │ \multicolumn{1}{l}{ 0.31} │ 0.35
2022Learning Differential Operators (hybrid PDE with meta-learning controller; Ours) proposedtest RMSE2.3266Motor Imagery Classification · split: testLearning Differential Operators for Interpretable Time Series Modeling
Source quote
L202: 2.3551 │ 2.3291 │ 2.4673 │ 2.3266
2022STING proposed non-standard sliceRMSE0.0531Time Series Imputation · subset=training set A · repetitions=10 · held-out-observed-values=20%STING: Self-attention based Time-series Imputation Networks using GAN
Source quote
L205: STING │ 0.0531 │ 0.0238 │ 0.0153
2022NIERT proposedaverage MSE (×10^-3)2.868Motor Imagery ClassificationNIERT: Accurate Numerical Interpolation through Unifying Scattered Data Representations using Transformer Encoder
Source quote
L276: Accuracy on PhysioNet dataset: Table \ref{table:PhysioNet} suggests that on the PhysioNet dataset, NIERT also outperforms the existing approaches, e.g., when controlling the ratio of observed points to be 50%, NIERT achieves an average MSE (× 10 (-3)) of 2.868, significantly lower than other approaches. Again, NIERT with the pre-training technique shows better performance. The advantages of NIERT hold across various settings of the ratio of the observed points.
2022SplineNet encoder-decoder proposedreconstruction error0.0023Time Series Forecasting · forecast-window=10-stepIrregularly-Sampled Time Series Modeling with Spline Networks
Source quote
L125: Forecasting. We would like to encode the time series to predict the future values using the same encoder-decoder architectures as before. We use Physionet and Speech Commands dataset with the forecast window of 10 steps. Our method again outperforms the GRU-ODE model, we obtain reconstruction error of 0.0023 and 0.1736, compared to GRU's 0.0025 and 0.1754, on Physionet and Speech, respectively.
2022Dynamic EEGInception proposedDynamic Avg. Accuracy83.9%Motor Imagery Classification · leave-one-subject-out · epochs=30 · classes=left-vs-right-hand · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L157: 83.9% p-value ≈0.0068
2022Dynamic EEGInception proposedDynamic Avg. Accuracy71.4%Motor Imagery Classification · leave-one-subject-out · epochs=30 · classes=left-hand/right-hand/feet · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L161: 71.4% p-value ≈0.00025
2022Dynamic DeepConvNet proposedDynamic Avg. Accuracy71.3%Motor Imagery Classification · leave-one-subject-out · epochs=30 · classes=left-hand/right-hand/feet · excluded-subjects=88, 89, 92, 100, 104, 106A CAUSAL VIEWPOINT ON MOTOR-IMAGERY BRAINWAVE DECODING
Source quote
L145: 71.3% p-value ≈0.0000328
2022Ours (ensemble curriculum learning and collaborative training), K=7 proposedAccuracy86.36%Motor Imagery Classification · split: test · K=7 · evaluation=5-fold subject-level cross-validationMotor Imagery Decoding Using Ensemble Curriculum Learning and Collaborative Training
Source quote
L153: Ours, K=7 │ 15.7K │ 86.36
2022Ours (ensemble curriculum learning and collaborative training), K=7 proposedAccuracy85.82%Motor Imagery Classification · split: test · K=7 · evaluation=leave-one-subject-outMotor Imagery Decoding Using Ensemble Curriculum Learning and Collaborative Training
Source quote
L185: Ours, K=7 │ 15.7K │ 85.82
2021Att-NDE proposedAUC0.833Mortality Prediction · prediction-horizon=first 48 hoursContinuous-Time Attention for Sequential Learning
Source quote
L364: 0.833
2020warpSKI proposedTime for Inference0.27 sFetal Ecg Extraction · input_points=5000 · sampling_rate=500 Hz · fetal_inducing_points=4800 · maternal_inducing_points=3400Scalable Gaussian Process Separation for Kernels with a Non-Stationary Phase
Source quote
L286: 0.27 s
2020warpSKI proposedTime for Inference4.14 sFetal Ecg Extraction · input_points=100000 · sampling_rate=1000 Hz · fetal_inducing_points=21600 · maternal_inducing_points=14300Scalable Gaussian Process Separation for Kernels with a Non-Stationary Phase
Source quote
L287: 4.14 s
2020warpSKI proposedTime for learning462.3 sFetal Ecg Extraction · input_points=100000 · sampling_rate=1000 Hz · fetal_inducing_points=21600 · maternal_inducing_points=14300Scalable Gaussian Process Separation for Kernels with a Non-Stationary Phase
Source quote
L291: 462.3 s
2020Proposed robust RNN proposedMicro-averaged AUC0.90Motor Imagery ClassificationMedi-Care AI: Predicting medications from billing codes via robust recurrent neural networks
Source quote
L219: \parbox[t]{1mm}{\multirow{5}{*}{\rotatebox[origin=c]{90}{RNN}}} │ Ours │ \color{red}0.90 │ \color{red}0.78
2019E2GAN + Simple RNN Model proposed non-standard sliceAUC0.8724Mortality Prediction · classifier=Simple RNN · imputation-method=E2GANE²GAN: End-to-End Generative Adversarial Network for Multivariate Time Series Imputation
Source quote
L414: 0.8724(1.4%)
2019Bayesian recurrent framework proposedMRE0.398Time Series ImputationBayesian Recurrent Framework for Missing Data Imputation and Prediction with Clinical Time Series
Source quote
L75: Ours │ 0.282 │ 0.398 │ 0.866 │ 0.553
2019Bayesian recurrent framework proposedAUPRC0.553Mortality PredictionBayesian Recurrent Framework for Missing Data Imputation and Prediction with Clinical Time Series
Source quote
L75: Ours │ 0.282 │ 0.398 │ 0.866 │ 0.553
20177-layer RNN with 2 LSTM layers proposedAccuracy0.9553Intent Recognition · model=7-layer RNN with 2 LSTM layers · intents=5 · subjects=10Intent Recognition in Smart Living Through Deep Recurrent Neural Networks
Source quote
L161: Our intent recognition result, the confusion matrix and the corresponding evaluation are presented in Table~\ref{tab:table5}. It can be read that our approach produces a mean accuracy of 0.9553, in tests of five intents recognition on 10 subjects. The ROC (Receiver Operating Characteristic) curves of five intents are displayed in Figure~\ref{fig:roc}.