NTU-60
60 papers · 119 extracted observations · action recognition · video · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=x-sub.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ProtoGCN (6-ensemble) SOTA frontier | 93.8% | 2025-01-01 | ensemble=six-stream · X-Sub; six-stream ensemble. NTU-60 X-Sub is one of the two reported settings. | Revealing Key Details to See Differences: A Novel Prototypical Perspective for Skeleton-based Action RecognitionSource quoteProtoGCN (6-ensemble) │ 93.8 │ 97.8 │ 90.9 │ 92.2 │ 51.9 │ 75.6 |
| 2 | FreqMixFormer (4-stream ensemble) SOTA frontier | 93.4% | 2024-07-01 | streams=S1+S2+S4+S5 · ensemble=4-stream · X-Sub; 4-stream ensemble (S1+S2+S4+S5). | Frequency Guidance Matters: Skeletal Action Recognition by Frequency-Aware Mixed TransformerSource quoteComparisons for NTU datasets are shown in Table \ref{tab: nturesult}. We compare our model with the recent SOTA methods based on their frameworks (GCN and Transformer). The recognition accuracy of our FreqMixFormer has outperformed all the transformer-based methods. It is noted that even our 4-stream ensemble results on both NTU-60 (93.4% in X-Sub and 97.3% in X-View) and NTU-120 datasets (90.2% in X-Sub and 91.5% in X-Set) have exceeded all SOTA approaches. |
| 3 | FreqMixFormerV2 | 90.7% | 2025-01-01 | stream=joint · X-Sub; joint-stream (J) | FreqMixFormerV2: Lightweight Frequency-aware Mixed Transformer for Human Skeleton Action RecognitionSource quote\multicolumn{2}{c}{FreqMixFormerV2} │ Transformer │ J │ \textbf{\textcolor{red}{1.2}} │ 90.7 │ 95.4 │ 87.6 │ 88.5 │ 96.2 |
| 4 | SCD-Net (Ours), combined joint-, motion-, and bone-based inputs (J+M+B) SOTA frontier (+3 variants) | 87.3% | 2024-01-01 | input=joint+motion+bone · Cross-subject evaluation; combined joint, motion, and bone inputs. | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteSCD-Net (Ours) │ 86.6 │ 82.9 │ 82.8 │ 87.3 |
Metricaccuracy (60)top 1 accuracy (21)performance (5)xsub (3)final forgetting ff (3)linear evaluation score (3)
Showing 9 of 9 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | ART (ViT-L/14) proposed | Top-1 accuracy | 95.2% | split: xview · input=video · backbone=ViT-L/14 · evaluation=cross-view | Towards an Effective Action-Region Tracking Framework for Fine-grained Video Action RecognitionSource quoteL414: ART (ViT-L/14) │ \ding{55} │ \usym{1F5F8} │ \textcolor{red}{95.2} │ \textcolor{red}{93.1} │ \textcolor{red}{90.5} │ \textcolor{red}{88.7} |
| 2025 | Neuron (two-stream) baseline | GZSL H | 73.2 | split: xview · 0-shot · fusion=two-stream · features=STAR-based Shift-GCN · protocol=GZSL · seen-unseen-split=55/5 | Learning by Neighbor-Aware Semantics, Deciding by Open-form Flows: Towards Robust Zero-Shot Skeleton Action RecognitionSource quoteL570: Neuron^{\color{Orange}\boldsymbol{\ddagger}}~\cite{chen2025neuron} │ CVPR 2025 │ \textcolor{red}{87.8} │ 70.6 │ \textcolor{blue}{75.9} │ \textcolor{blue}{73.2} │ \textcolor{blue}{63.3} │ \textcolor{blue}{65.3} │ \textcolor{red}{58.1} │ \textcolor{red}{61.5} │ \textcolor{blue}{71.1} │ \textcolor{red}{67.5} │ 58.9 │ \textcolor{blue}{62.9} │ \textcolor{blue}{54.0} │ \textcolor{red}{67.0} │ \textcolor{blue}{44.9} │ \textcolor{blue}{53.8} |
| 2024 | MacDiff w/o aug ablation | action recognition accuracy | 77.3 | split: xview · fine-tuned · runs=5 · augmentation=none · training-data=1% | MacDiff: Unified Skeleton Modeling with Masked Conditional DiffusionSource quoteL353: MacDiff w/o aug │ 65.6 │ 80.7 │ 88.2 │ 77.3 │ 84.1 │ 92.5 |
| 2023 | CMCS proposed | acc. | 84.5% | split: xview · linear-probe · streams=J+M+B | Cross-Model Cross-Stream Learning for Self-Supervised Human Action RecognitionSource quoteL298: CMCS (Ours) │ J+M+B │ 78.6 │ \uparrow 0.8 │ 84.5 │ \uparrow 0.9 │ 88.1 │ \uparrow 3.2 │ 53.4 │ \uparrow 32.2 │ 68.5 │ \uparrow 0.6 │ 71.1 │ \uparrow 4.4 } |
| 2023 | HYSP w/ neg. (MoCo replacing BYOL) ablation | performance | 69.7 | split: xview · linear-probe | Hyperbolic Self-paced Learning for Self-supervised Skeleton-based Action RepresentationsSource quoteL269: \CH{82.6} │ \CH{69.7} │ \CH{76.9} │ \CH{73.9} │ \CH{85.2} │ \CH{75.5} |
| 2023 | HYSP w/o hyperbolic mapping ablation | performance | 76.9 | split: xview · linear-probe | Hyperbolic Self-paced Learning for Self-supervised Skeleton-based Action RepresentationsSource quoteL269: \CH{82.6} │ \CH{69.7} │ \CH{76.9} │ \CH{73.9} │ \CH{85.2} │ \CH{75.5} |
| 2023 | HYSP w/o curriculum learning ablation | performance | 73.9 | split: xview · linear-probe | Hyperbolic Self-paced Learning for Self-supervised Skeleton-based Action RepresentationsSource quoteL269: \CH{82.6} │ \CH{69.7} │ \CH{76.9} │ \CH{73.9} │ \CH{85.2} │ \CH{75.5} |
| 2022 | GL-Transformer proposed | Accuracy | 83.8% | split: xview · linear-probe | Global-Local Motion Transformer for Unsupervised Skeleton-Based Action LearningSource quoteL415: GL-Transformer │ Transformer │ 76.3 │ 83.8 |
| 2021 | 3s-AimCLR proposed | linear-evaluation score | 83.8% | split: xview · linear-probe · streams=three-stream fusion | Contrastive Learning from Extremely Augmented Skeleton Sequences for Self-Supervised Action RecognitionSource quoteL258: 3s-AimCLR (ours) │ 78.9 │ 83.8 |