NTU-60

60 papers · 119 extracted observations · action recognition · video · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=x-sub.

81.986.290.494.720242025SCD-Net (Ours), bone-based input (B): 82.8 (2024)SCD-Net (Ours), motion-based input (M): 82.9 (2024)SCD-Net (Ours), joint-based input (J): 86.6 (2024)SCD-Net (Ours), combined joint-, motion-, and bone-based inputs (J+M+B): 87.3 (2024)FreqMixFormer (4-stream ensemble): 93.4 (2024)FreqMixFormerV2: 90.7 (2025)ProtoGCN (6-ensemble): 93.8 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 21 of 21 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026AMR proposedtop-1 accuracy72.2split: x-sub · fine-tuned · labeled-data=1%Exploring Adaptive Masked Reconstruction for Self-Supervised Skeleton-Based Action Recognition
Source quote
L236: AMR (Ours) │ 72.2 │ 89.0 │ 74.4 │ 92.7
2026AMR proposedtop-1 accuracy89.0split: x-sub · fine-tuned · labeled-data=10%Exploring Adaptive Masked Reconstruction for Self-Supervised Skeleton-Based Action Recognition
Source quote
L236: AMR (Ours) │ 72.2 │ 89.0 │ 74.4 │ 92.7
2026AMR proposedtop-1 accuracy74.4split: x-view · fine-tuned · labeled-data=1%Exploring Adaptive Masked Reconstruction for Self-Supervised Skeleton-Based Action Recognition
Source quote
L236: AMR (Ours) │ 72.2 │ 89.0 │ 74.4 │ 92.7
2026AMR proposedtop-1 accuracy92.7split: x-view · fine-tuned · labeled-data=10%Exploring Adaptive Masked Reconstruction for Self-Supervised Skeleton-Based Action Recognition
Source quote
L236: AMR (Ours) │ 72.2 │ 89.0 │ 74.4 │ 92.7
2026EAST with difference masking (k=0.5) ablationaverage top-1 accuracy74.3masking=difference · masked-token-ratio=0.5 · observation-ratios=0.1–0.9EAST: Early Action Prediction Sampling Strategy with Token Masking
Source quote
L1098: \mdiff-k\!=\!0.5 │ 31.2 │ 49.6 │ 69.4 │ 81.3 │ 86.2 │ 87.6 │ 87.9 │ 88.0 │ 87.9 │ 74.3
2025ART (ViT-L/14) proposedTop-1 accuracy95.2%split: xview · input=video · backbone=ViT-L/14 · evaluation=cross-viewTowards an Effective Action-Region Tracking Framework for Fine-grained Video Action Recognition
Source quote
L414: ART (ViT-L/14) │ \ding{55} │ \usym{1F5F8} │ \textcolor{red}{95.2} │ \textcolor{red}{93.1} │ \textcolor{red}{90.5} │ \textcolor{red}{88.7}
2025DynaPURLS proposedZSL Top-1 accuracy86.750-shot · trials=3 random splits · class-split=55/5 seen/unseenDynaPURLS: Dynamic Refinement of Part-aware Representations for Skeleton-based Zero-Shot Action Recognition
Source quote
L377: DynaPURLS(Ours) │ 86.75 │ 79.44 │ 90.04 │ 74.72 │ 78.26 │ 60.11
2025GFP proposedtop-1 accuracy71.8split: x-sub · semi-supervised · labeled-data=1%Towards Efficient General Feature Prediction in Masked Skeleton Modeling
Source quote
L328: GFP (Ours) │ 71.8 │ 88.7 │ 72.9 │ 92.1
2025GFP proposedtop-1 accuracy88.7split: x-sub · semi-supervised · labeled-data=10%Towards Efficient General Feature Prediction in Masked Skeleton Modeling
Source quote
L328: GFP (Ours) │ 71.8 │ 88.7 │ 72.9 │ 92.1
2025GFP proposedtop-1 accuracy72.9split: x-view · semi-supervised · labeled-data=1%Towards Efficient General Feature Prediction in Masked Skeleton Modeling
Source quote
L328: GFP (Ours) │ 71.8 │ 88.7 │ 72.9 │ 92.1
2025GFP proposedtop-1 accuracy92.1split: x-view · semi-supervised · labeled-data=10%Towards Efficient General Feature Prediction in Masked Skeleton Modeling
Source quote
L328: GFP (Ours) │ 71.8 │ 88.7 │ 72.9 │ 92.1
20233Mformer (with rank-pool) proposedtop-1 accuracy94.8%first of the two NTU-60 evaluation protocols3Mformer: Multi-order Multi-mode Transformer for Skeletal Action Recognition
Source quote
L298: 3Mformer (with rank-pool, {\em ours}) │ {\bf 94.8} │ {\bf 98.7} │ {\bf 92.0} │ {\bf 93.8} │ {\bf 48.3} │ {\bf 72.3}
20233Mformer (with rank-pool) proposedtop-1 accuracy98.7%second of the two NTU-60 evaluation protocols3Mformer: Multi-order Multi-mode Transformer for Skeletal Action Recognition
Source quote
L298: 3Mformer (with rank-pool, {\em ours}) │ {\bf 94.8} │ {\bf 98.7} │ {\bf 92.0} │ {\bf 93.8} │ {\bf 48.3} │ {\bf 72.3}
2023I^2MD proposedtop-1 accuracy66.9split: x-view · semi-supervised · evaluation=single-modality; no ensembling · labeled_fraction=1%$\hbox {I}^2$MD: 3D Action Representation Learning with Inter- and Intra-Modal Mutual Distillation
Source quote
L320: I^2MD (Ours) │ 66.9 │ 84.7 │ 66.9 │ 81.1
2023I^2MD proposedtop-1 accuracy66.9split: x-sub · semi-supervised · evaluation=single-modality; no ensembling · labeled_fraction=1%$\hbox {I}^2$MD: 3D Action Representation Learning with Inter- and Intra-Modal Mutual Distillation
Source quote
L320: I^2MD (Ours) │ 66.9 │ 84.7 │ 66.9 │ 81.1
2023CPM baselinetop-1 accuracy57.5split: x-view · semi-supervised · labeled_fraction=1%$\hbox {I}^2$MD: 3D Action Representation Learning with Inter- and Intra-Modal Mutual Distillation
Source quote
L317: CPM \citep{zhang2022contrastive} │ ECCV'2022 │ 57.5 │ 77.1 │ 56.7 │ 73.0
2023CPM baselinetop-1 accuracy56.7split: x-sub · semi-supervised · labeled_fraction=1%$\hbox {I}^2$MD: 3D Action Representation Learning with Inter- and Intra-Modal Mutual Distillation
Source quote
L317: CPM \citep{zhang2022contrastive} │ ECCV'2022 │ 57.5 │ 77.1 │ 56.7 │ 73.0
2022CMD (Ours), joint-only proposedtop-1 accuracy79.8linear-probe · modality=joint-only · protocol=cross-subjectCMD: Self-supervised 3D Action Representation Learning with Cross-Modal Mutual Distillation
Source quote
L247: CMD (Ours) │ Joint only │ 79.8 │ 86.9 │ 70.3 │ 71.5 │ 43.0
2022CMD (Ours), joint-only proposedtop-1 accuracy86.9linear-probe · modality=joint-only · protocol=cross-viewCMD: Self-supervised 3D Action Representation Learning with Cross-Modal Mutual Distillation
Source quote
L247: CMD (Ours) │ Joint only │ 79.8 │ 86.9 │ 70.3 │ 71.5 │ 43.0
2022CMD proposedtop-1 accuracy70.6modality=joint · protocol=cross-subject · evaluation=1-nearest-neighborCMD: Self-supervised 3D Action Representation Learning with Cross-Modal Mutual Distillation
Source quote
L270: CMD (Ours) │ 70.6 │ 85.4 │ 58.3 │ 60.9
2021ST-TR baselineTop-1 Acc.94.0The summary table does not specify the split or evaluation setup.Transformers in Vision: A Survey
Source quote
L488: 94.0/84.7