NTU-60
60 papers · 119 extracted observations · action recognition · video · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=x-sub.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | ProtoGCN (6-ensemble) SOTA frontier | 93.8% | 2025-01-01 | ensemble=six-stream · X-Sub; six-stream ensemble. NTU-60 X-Sub is one of the two reported settings. | Revealing Key Details to See Differences: A Novel Prototypical Perspective for Skeleton-based Action RecognitionSource quoteProtoGCN (6-ensemble) │ 93.8 │ 97.8 │ 90.9 │ 92.2 │ 51.9 │ 75.6 |
| 2 | FreqMixFormer (4-stream ensemble) SOTA frontier | 93.4% | 2024-07-01 | streams=S1+S2+S4+S5 · ensemble=4-stream · X-Sub; 4-stream ensemble (S1+S2+S4+S5). | Frequency Guidance Matters: Skeletal Action Recognition by Frequency-Aware Mixed TransformerSource quoteComparisons for NTU datasets are shown in Table \ref{tab: nturesult}. We compare our model with the recent SOTA methods based on their frameworks (GCN and Transformer). The recognition accuracy of our FreqMixFormer has outperformed all the transformer-based methods. It is noted that even our 4-stream ensemble results on both NTU-60 (93.4% in X-Sub and 97.3% in X-View) and NTU-120 datasets (90.2% in X-Sub and 91.5% in X-Set) have exceeded all SOTA approaches. |
| 3 | FreqMixFormerV2 | 90.7% | 2025-01-01 | stream=joint · X-Sub; joint-stream (J) | FreqMixFormerV2: Lightweight Frequency-aware Mixed Transformer for Human Skeleton Action RecognitionSource quote\multicolumn{2}{c}{FreqMixFormerV2} │ Transformer │ J │ \textbf{\textcolor{red}{1.2}} │ 90.7 │ 95.4 │ 87.6 │ 88.5 │ 96.2 |
| 4 | SCD-Net (Ours), combined joint-, motion-, and bone-based inputs (J+M+B) SOTA frontier (+3 variants) | 87.3% | 2024-01-01 | input=joint+motion+bone · Cross-subject evaluation; combined joint, motion, and bone inputs. | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteSCD-Net (Ours) │ 86.6 │ 82.9 │ 82.8 │ 87.3 |
Metricaccuracy (60)top 1 accuracy (21)performance (5)xsub (3)final forgetting ff (3)linear evaluation score (3)
Showing 14 of 14 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | UKTL, combined sum-product kernel proposed | Accuracy | 93.1\% | split: x-sub · kernel=combined sum-product | Subspace Kernel Learning on Tensor SequencesSource quoteL376: Below we compare sum-only, product-only, and combined (sum-product) kernels. As shown in Fig.~\ref{fig:ntu-60-sum-product-kernel}, the sum-kernel yields 81.6% (X-Sub), while the product-kernel achieves 91.8%. Their combination reaches the highest accuracy, 93.1% (X-Sub) and 97.3% (X-View), demonstrating that additive and multiplicative structures capture complementary information. |
| 2026 | UKTL, sum-only kernel ablation | Accuracy | 81.6\% | split: x-sub · kernel=sum-only | Subspace Kernel Learning on Tensor SequencesSource quoteL376: Below we compare sum-only, product-only, and combined (sum-product) kernels. As shown in Fig.~\ref{fig:ntu-60-sum-product-kernel}, the sum-kernel yields 81.6% (X-Sub), while the product-kernel achieves 91.8%. Their combination reaches the highest accuracy, 93.1% (X-Sub) and 97.3% (X-View), demonstrating that additive and multiplicative structures capture complementary information. |
| 2026 | UKTL, product-only kernel ablation | Accuracy | 91.8\% | split: x-sub · kernel=product-only | Subspace Kernel Learning on Tensor SequencesSource quoteL376: Below we compare sum-only, product-only, and combined (sum-product) kernels. As shown in Fig.~\ref{fig:ntu-60-sum-product-kernel}, the sum-kernel yields 81.6% (X-Sub), while the product-kernel achieves 91.8%. Their combination reaches the highest accuracy, 93.1% (X-Sub) and 97.3% (X-View), demonstrating that additive and multiplicative structures capture complementary information. |
| 2025 | ST-GCN baseline | Accuracy | 92.90% | split: x-sub · modality=skeleton | Modeling Human Skeleton Joint Dynamics for Fall DetectionSource quoteL180: ST-GCN \cite{Keskes_2021} │ \hfil Skeleton │ \hfil X-Sub │ \hfil 92.90% \bigstrut |
| 2024 | FreqMixFormerV2 proposed | Accuracy | 90.7% | split: x-sub · stream=joint | FreqMixFormerV2: Lightweight Frequency-aware Mixed Transformer for Human Skeleton Action RecognitionSource quoteL179: \multicolumn{2}{c}{FreqMixFormerV2} │ Transformer │ J │ \textbf{\textcolor{red}{1.2}} │ 90.7 │ 95.4 │ 87.6 │ 88.5 │ 96.2 |
| 2024 | FreqMixFormer (4-stream ensemble) proposed | recognition accuracy | 93.4% | split: x-sub · streams=S1+S2+S4+S5 · ensemble=4-stream | Frequency Guidance Matters: Skeletal Action Recognition by Frequency-Aware Mixed TransformerSource quoteL284: Comparisons for NTU datasets are shown in Table \ref{tab: nturesult}. We compare our model with the recent SOTA methods based on their frameworks (GCN and Transformer). The recognition accuracy of our FreqMixFormer has outperformed all the transformer-based methods. It is noted that even our 4-stream ensemble results on both NTU-60 (93.4% in X-Sub and 97.3% in X-View) and NTU-120 datasets (90.2% in X-Sub and 91.5% in X-Set) have exceeded all SOTA approaches. |
| 2024 | U-FEFP (3S) proposed | accuracy, X-Sub | 86.92% | split: x-sub · unsupervised · configuration=3S | Unsupervised Spatial-Temporal Feature Enrichment and Fidelity Preservation Network for Skeleton based Action RecognitionSource quoteL341: U-FEFP (3S) │ unsupervised │ 86.92 │ 91.44 |
| 2024 | ProtoGCN (6-ensemble) proposed | classification accuracy | 93.8% | split: x-sub · ensemble=six-stream | Revealing Key Details to See Differences: A Novel Prototypical Perspective for Skeleton-based Action RecognitionSource quoteL284: ProtoGCN (6-ensemble) │ 93.8 │ 97.8 │ 90.9 │ 92.2 │ 51.9 │ 75.6 |
| 2023 | SCD-Net (Ours), joint-based input (J) proposed | Accuracy | 86.6% | split: x-sub · input=joint | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteL686: SCD-Net (Ours) │ 86.6 │ 82.9 │ 82.8 │ 87.3 |
| 2023 | SCD-Net (Ours), combined joint-, motion-, and bone-based inputs (J+M+B) proposed | Accuracy | 87.3% | split: x-sub · input=joint+motion+bone | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteL686: SCD-Net (Ours) │ 86.6 │ 82.9 │ 82.8 │ 87.3 |
| 2023 | SCD-Net (Ours), motion-based input (M) proposed | Accuracy | 82.9% | split: x-sub · input=motion | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteL686: SCD-Net (Ours) │ 86.6 │ 82.9 │ 82.8 │ 87.3 |
| 2023 | SCD-Net (Ours), bone-based input (B) proposed | Accuracy | 82.8% | split: x-sub · input=bone | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteL686: SCD-Net (Ours) │ 86.6 │ 82.9 │ 82.8 │ 87.3 |
| 2023 | HiCo-LSTM, joint-based input (J) baseline | Accuracy | 81.4% | split: x-sub · input=joint | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteL683: HiCo-LSTM~\cite{dong2023hierarchical} │ 81.4 │ 78.9 │ 81.0 │ 83.8 |
| 2023 | HiCo-LSTM, combined joint-, motion-, and bone-based inputs (J+M+B) baseline | Accuracy | 83.8% | split: x-sub · input=joint+motion+bone | SCD-Net: Spatiotemporal Clues Disentanglement Network for Self-Supervised Skeleton-Based Action RecognitionSource quoteL683: HiCo-LSTM~\cite{dong2023hierarchical} │ 81.4 │ 78.9 │ 81.0 │ 83.8 |