NTU-60

60 papers · 119 extracted observations · action recognition · video · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=x-sub.

81.986.290.494.720242025SCD-Net (Ours), bone-based input (B): 82.8 (2024)SCD-Net (Ours), motion-based input (M): 82.9 (2024)SCD-Net (Ours), joint-based input (J): 86.6 (2024)SCD-Net (Ours), combined joint-, motion-, and bone-based inputs (J+M+B): 87.3 (2024)FreqMixFormer (4-stream ensemble): 93.4 (2024)FreqMixFormerV2: 90.7 (2025)ProtoGCN (6-ensemble): 93.8 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025FS-VAE with calibrated alignment loss proposedACC (accuracy)86.9%split: test · 0-shot · class-split=55/5Frequency-Semantic Enhanced Variational Autoencoder for Zero-Shot Skeleton-based Action Recognition
Source quote
L689: Ours │ \textbf{\textcolor{red}{86.9}} │ \textbf{\textcolor{red}{57.2}} │ \textbf{\textcolor{red}{74.4}} │ \textbf{\textcolor{red}{62.5}}
2025Triplet alignment loss \mathcal{L}-T,4 ablationACC (accuracy)85.3%split: test · 0-shot · class-split=55/5 · alignment-loss=tripletFrequency-Semantic Enhanced Variational Autoencoder for Zero-Shot Skeleton-based Action Recognition
Source quote
L687: \mathcal{L}-T,4 │ \textbf{\textcolor{blue}{85.3}} │ 42.2 │ 69.0 │ 49.7
2024CTR-GCN (no additional anti-noise methods)test accuracy64.8%split: testSkeleton-Based Human Action Recognition with Noisy Labels
Source quote
L329: Then, we analyze the CTR-GCN model's robustness without any additional anti-noise methods. Our experiments indicate that the CTR-GCN model remains sufficient robustness under 20% to 50% noise ratio, with test accuracy dropping from 86.8% to 81.7% (cross-subject) and from 90.9% to 85.7% (cross-view). However, at 80% noise, a significant accuracy decline is evident, with 64.8% (cross-subject) and 64.6% (cross-view).
2024CTR-GCN (no additional anti-noise methods)test accuracy64.6%split: testSkeleton-Based Human Action Recognition with Noisy Labels
Source quote
L329: Then, we analyze the CTR-GCN model's robustness without any additional anti-noise methods. Our experiments indicate that the CTR-GCN model remains sufficient robustness under 20% to 50% noise ratio, with test accuracy dropping from 86.8% to 81.7% (cross-subject) and from 90.9% to 85.7% (cross-view). However, at 80% noise, a significant accuracy decline is evident, with 64.8% (cross-subject) and 64.6% (cross-view).