NIH ChestX-ray14

41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API

Also indexed as: nih-chestx-ray14

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.80.9201920222025Proposed model with a 1×1 capsule convolutional layer: 0.775 (2018)XProtoNet (ResNet-50): 0.82 (2021)XProtoNet (DenseNet-121): 0.822 (2021)Clinical-BERT (Ours; proposed pre-trained model): 0.845 (2022)Self confidence: 0.6 (2023)GTDA error estimation: 0.75 (2023)DGFN: 0.85 (2023)proposed causal approach: 0.857 (2023)CIPL: 0.828 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 44 of 44 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026CRC-Router (standalone) proposedMacro wrong-accept risk3.9%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L153: Macro │ 9.2% │ 4.5% │ 6.5% │ 4.7% │ 3.9% │ \downarrow58%
2026MedRAX + CRC-Router (MoE) proposedMacro wrong-accept risk3.8%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6%
2026TENT baselinemean AUROC54.0split: test · test-time-adaptationLeveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4
2025DenseNet trained on NIH-WA proposedPI Score3.31%split: test · backbone=DenseNet · training-data=NIH-WACheXwhatsApp: A Dataset for Exploring Challenges in the Diagnosis of Chest X-rays through Mobile Devices
Source quote
L206: 3.31 (79%)
2025ResNeXt trained on NIH-WA proposedOLS Score (GradCAM++)10.51split: test · backbone=ResNeXt · training-data=NIH-WA · attribution-method=GradCAM++CheXwhatsApp: A Dataset for Exploring Challenges in the Diagnosis of Chest X-rays through Mobile Devices
Source quote
L285: 10.51 (82%)
2025MEGANet baselineIoU88.19split: test · 0-shot · modality=X-ray · source-dataset=MontgomeryU-Bench: A Comprehensive Understanding of U-Net through 100-Variant Benchmarking
Source quote
L1040: \raisebox{-4pt}{} │ MEGANet │ {88.19}
2025DenseNet trained on NIH baselinePI Score15.74%split: test · backbone=DenseNet · training-data=NIHCheXwhatsApp: A Dataset for Exploring Challenges in the Diagnosis of Chest X-rays through Mobile Devices
Source quote
L205: 15.74
2025ResNeXt trained on NIH baselineOLS Score (GradCAM++)61.24split: test · backbone=ResNeXt · training-data=NIH · attribution-method=GradCAM++CheXwhatsApp: A Dataset for Exploring Challenges in the Diagnosis of Chest X-rays through Mobile Devices
Source quote
L278: 61.24
2024CIPL proposedMean AUC0.828split: testCross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and Interpretation
Source quote
L541: As can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885,
2023proposed causal approach proposedMean AUC0.857split: test · backbone=ResNet101Chest X-ray Image Classification: A Causal Perspective
Source quote
L151: Mean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864)
2023DGFN proposedMean AUC0.850split: testDeep reinforcement learning framework for thoracic diseases classification via prior knowledge guidance
Source quote
L291: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873)
2023E-D6 proposed non-standard sliceSensitivity76.7%split: test · subset=curated external subset · training-data-exclusion=very subtle and extremely subtle JSRT nodules · false-positives-per-image=7.6Full-resolution Lung Nodule Segmentation from Chest X-ray Images using Residual Encoder-Decoder Networks
Source quote
L1061: In external testing, E-D6 provided an excellent generalization result when very subtle and extremely subtle nodules were excluded from the JSRT training data. Internally, at 1024 x 1024 pixels, E-D6 achieved a sensitivity of 83.6% with 8.3 false positives per image. Externally E-D6 achieved a sensitivity of 76.7% at 7.6 false positives per image.
2022MAE-pretrained ViT-S/16 proposedmAUC (mean AUC over 14 diseases)82.3%split: test · fine-tuned · params=0.3M · backbone=ViT-S/16 · pretraining-data=0.3M X-raysDelving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L370: MAE │ ViT-S/16 │ 82.3
2022MAE-pretrained DenseNet-121 (DN121) proposedmAUC81.2%split: test · fine-tuned · params=0.3M · backbone=DenseNet-121 · pretraining-data=0.3M X-raysDelving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L369: MAE │ DN121 │ 81.2
2022KAFAL proposedmAUC63.61split: test · alpha=0.1 · clients=5 · labeled-data=15% · client-update-fraction=80%Knowledge-Aware Federated Active Learning with Non-IID Data
Source quote
L389: \bf KAFAL (ours) │ 63.61 │ 64.48
2022KAFAL proposedmAUC64.48split: test · alpha=0.1 · clients=5 · labeled-data=20% · client-update-fraction=80%Knowledge-Aware Federated Active Learning with Non-IID Data
Source quote
L389: \bf KAFAL (ours) │ 63.61 │ 64.48
2022Clinical-BERT (Ours; proposed pre-trained model) proposedMean AUC0.8450split: testClinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports Generation
Source quote
L544: 0.8450
2022GTDA error estimationAUC0.75split: testTopological structure of complex predictions
Source quote
L550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60.
2022Self confidenceAUC0.60split: testTopological structure of complex predictions
Source quote
L550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60.
2022DME baselineMean AUC0.8349split: testClinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports Generation
Source quote
L543: 0.8349
2021CheXDet proposedJAFROC-FOM0.55split: test · subset=880 frontal radiographs · finding=pneumothoraxRethinking annotation granularity for overcoming deep shortcut learning: A retrospective study on chest radiographs
Source quote
L38: CheXDet achieved higher lesion localization performance than CheXNet for most abnormalities on all datasets, such as in detecting pneumothorax on the internal testing sets (CheXDet jacknife alternative free-respnse ROCfigure of merit [JAFROC-FOM]: 0.87, CheXNet JAFROC-FOM: 0.13; p<.001) and the external NIH-ChestXray14 dataset (CheXDet JAFROC-FOM: 0.55, CheXNet JAFROC-FOM: 0.04; p<.001).
2021CXR-ML-GZSL (OUR_e2e) proposedprecision@2 (p@k, k=2)0.33split: test · generalized-zero-shot · prediction=top-2Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021CXR-ML-GZSL (OUR_e2e) proposedAUROC for unseen classes (U)0.66split: test · generalized-zero-shot · class-set=unseenMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021CXR-ML-GZSL (OUR_e2e) proposedharmonic mean AUROC (H) across seen and unseen classes0.72split: test · generalized-zero-shotMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021XProtoNet (ResNet-50) proposedMean AUC0.820split: test · backbone=ResNet-50XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792.
2021XProtoNet (DenseNet-121) proposedMean AUC0.822split: test · backbone=DenseNet-121XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822.
2021CheXNet (Rajpurkar et al.) baselineMean AUC across 8 chest diseases0.828split: testKnowledge-Augmented Contrastive Learning for Abnormality Classification and Localization in Chest X-rays with Radiomics using a Feedback Loop
Source quote
L136: Rajpurkar et. al.\cite{rajpurkar2017chexnet} │ 0.82 │ 0.91 │ 0.88 │ 0.72 │ 0.86 │ 0.78 │ 0.76 │ 0.89 │ 0.828
2021Li et al. baselineMean localization accuracy; correct if IoU exceeds the threshold0.728split: test · iou-threshold=0.1Knowledge-Augmented Contrastive Learning for Abnormality Classification and Localization in Chest X-rays with Radiomics using a Feedback Loop
Source quote
L170: Li et. al.\cite{li2018thoracic} │ 0.71 │ \textcolor{red}{0.98} │ 0.87 │ 0.92 │ 0.71 │ 0.40 │ 0.60 │ 0.63 │ 0.728
2021Li et al. baselineMean localization accuracy; correct if IoU exceeds the threshold0.622split: test · iou-threshold=0.2Knowledge-Augmented Contrastive Learning for Abnormality Classification and Localization in Chest X-rays with Radiomics using a Feedback Loop
Source quote
L173: Li et. al.\cite{li2018thoracic} │ 0.53 │ \textcolor{red}{0.97} │ 0.76 │ 0.83 │ 0.59 │ 0.29 │ 0.50 │ 0.51 │ 0.622
2021CheXNet baselineJAFROC-FOM0.04split: test · subset=880 frontal radiographs · finding=pneumothoraxRethinking annotation granularity for overcoming deep shortcut learning: A retrospective study on chest radiographs
Source quote
L38: CheXDet achieved higher lesion localization performance than CheXNet for most abnormalities on all datasets, such as in detecting pneumothorax on the internal testing sets (CheXDet jacknife alternative free-respnse ROCfigure of merit [JAFROC-FOM]: 0.87, CheXNet JAFROC-FOM: 0.13; p<.001) and the external NIH-ChestXray14 dataset (CheXDet JAFROC-FOM: 0.55, CheXNet JAFROC-FOM: 0.04; p<.001).
2021MLZSL baselineprecision@2 (p@k, k=2)0.19split: test · generalized-zero-shot · prediction=top-2Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62
2021MLZSL baselineAUROC for unseen classes (U)0.54split: test · generalized-zero-shot · class-set=unseenMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62
2021MLZSL baselineharmonic mean AUROC (H) across seen and unseen classes0.62split: test · generalized-zero-shotMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62
2021CheXNet (DenseNet121) baselineAUROC0.760split: test · test-images=420 · patient-disjoint=trueAdvancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative Analysis
Source quote
L109: 0.760
2021Highest-performing Patch r×r baseline (ResNet-50) baselineMean AUC0.792split: test · variant=Patch r×r · backbone=ResNet-50XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792.
2021Guan et al. (single DenseNet-121) baselineMean AUC0.816split: test · backbone=DenseNet-121XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822.
2020CIAN-CEN proposedMean disease localization accuracy0.67split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1Contralaterally Enhanced Networks for Thoracic Disease Detection
Source quote
L225: CIAN-CEN │ 0.71 │ 0.91 │ 0.74 │ 0.85 │ 0.79 │ 0.47 │ 0.40 │ 0.50 │ 0.67
2020CIAN baselineMean disease localization accuracy0.62split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1Contralaterally Enhanced Networks for Thoracic Disease Detection
Source quote
L224: CIAN~\cite{liu2019align} │ 0.67 │ 0.86 │ 0.71 │ 0.83 │ 0.77 │ 0.45 │ 0.29 │ 0.40 │ 0.62
2020Wang et al. baselineMean AUC across pathology classes0.75split: test · backbone=ResNet-50Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L212: Wang~et al. │ 0.70 │ 0.81 │ 0.70 │ 0.81 │ 0.76 │ 0.83 │ 0.79 │ 0.87 │ 0.66 │ 0.69 │ 0.67 │ 0.68 │ 0.66 │ 0.80 │ 0.75
2020Liu et al.* baselineMean AUC across pathology classes0.83split: test · backbone=ResNet-50 · additional-supervision=bounding-boxSelf-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L214: Liu~et al. * │ 0.79 │ 0.87 │ 0.79 │ 0.91 │ 0.88 │ 0.93 │ 0.80 │ 0.92 │ 0.69 │ 0.81 │ 0.73 │ 0.80 │ 0.75 │ 0.89 │ 0.83
2019proposed generative adversarial one-class model (U+D+E) proposed non-standard sliceAUC0.841split: test · runs=5 · training-data=normal CXRs onlyAbnormal Chest X-ray Identification With Generative Adversarial One-Class Classifier
Source quote
L111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage.
2019CheXNet reproduction (raw predictions across 50 retrainings) baselineMean coefficient of variation of predicted finding probabilities0.543split: test · fine-tuned · test_size=22,433 · retrainings=50 · training-batch-order=variedIndividual predictions matter: Assessing the effect of data ordering in training fine-tuned CNNs for medical imaging
Source quote
L48: Averaging model predictions significantly reduced the mean coefficient of variability from 0.543 to 0.169 (t-test 15.96, p-value < 0.0001). The distribution over AUC across models showed a degree of variability in both the full and limited test sets (Figure~\ref{fig:auc}, Table~\ref{table:auc}). In the limited test set, the empirical variability in predictions did not exceed the average DeLong or bootstrap confidence interval for each model (Table~\ref{table:auc}). The DeLong and bootstrap 95% confidence intervals for AUC contained the mean AUC across models in 99.7% of cases (n=698/700).
2019CheXNet reproduction (predictions averaged over groups of 10 models) baselineMean coefficient of variation of predicted finding probabilities0.169split: test · fine-tuned · aggregation=predictions averaged · models-per-group=10 · training-batch-order=variedIndividual predictions matter: Assessing the effect of data ordering in training fine-tuned CNNs for medical imaging
Source quote
L48: Averaging model predictions significantly reduced the mean coefficient of variability from 0.543 to 0.169 (t-test 15.96, p-value < 0.0001). The distribution over AUC across models showed a degree of variability in both the full and limited test sets (Figure~\ref{fig:auc}, Table~\ref{table:auc}). In the limited test set, the empirical variability in predictions did not exceed the average DeLong or bootstrap confidence interval for each model (Table~\ref{table:auc}). The DeLong and bootstrap 95% confidence intervals for AUC contained the mean AUC across models in 99.7% of cases (n=698/700).
2018Proposed model with a 1×1 capsule convolutional layer proposedAverage AUC0.775split: testDynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area Localization
Source quote
L102: Average │ 0.738 │ 0.761 │ 0.775 │ 0.626