NIH ChestX-ray14

41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API

Also indexed as: nih-chestx-ray14

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.80.9201920222025Proposed model with a 1×1 capsule convolutional layer: 0.775 (2018)XProtoNet (ResNet-50): 0.82 (2021)XProtoNet (DenseNet-121): 0.822 (2021)Clinical-BERT (Ours; proposed pre-trained model): 0.845 (2022)Self confidence: 0.6 (2023)GTDA error estimation: 0.75 (2023)DGFN: 0.85 (2023)proposed causal approach: 0.857 (2023)CIPL: 0.828 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 56 of 56 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.484split: test-evaluation-halfCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L303: best (Fig. 5a): AUROCf was 0.484 (0.468–0.502) for Dense-
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.524split: test-evaluation-half · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L304: Net-121 and 0.524 (0.509–0.539) for ViT-B/16, against
2026VIVID-Med proposedmacro-AUC0.72250-shotVIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTs
Source quote
L4: Vision-language pretraining has driven significant progress in medical image analysis. However, current methods typically supervise visual encoders using one-hot labels or free-form text, neither of which effectively captures the complex semantic relationships among clinical findings. In this study, we introduce VIVID-Med, a novel framework that leverages a frozen large language model (LLM) as a structured semantic teacher to pretrain medical vision transformers (ViTs). VIVID-Med translates clinical findings into verifiable JSON field-state pairs via a Unified Medical Schema (UMS), utilizing answerability-aware masking to focus optimization. It then employs Structured Prediction Decomposition (SPD) to partition cross-attention into orthogonality-regularized query groups, extracting complementary visual aspects. Crucially, the LLM is discarded post-training, yielding a lightweight, deployable ViT-only backbone. We evaluated VIVID-Med across multiple settings: on CheXpert linear probing, it achieves a macro-AUC of 0.8588, outperforming BiomedCLIP by {+}6.65 points while using 500× less data. It also demonstrates robust zero-shot cross-domain transfer to NIH ChestX-ray14 (0.7225 macro-AUC) and strong cross-modality generalization to CT, achieving 0.8413 AUC on LIDC-IDRI lung nodule classification and 0.9969 macro-AUC on OrganAMNIST 11-organ classification. VIVID-Med offers a highly efficient, scalable alternative to deploying resource-heavy vision-language models in clinical settings.
2026CRC-Router (standalone) proposedMacro wrong-accept risk3.9%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L153: Macro │ 9.2% │ 4.5% │ 6.5% │ 4.7% │ 3.9% │ \downarrow58%
2026MedRAX + CRC-Router (MoE) proposedMacro wrong-accept risk3.8%split: testCRC-Router: Risk-Constrained Routing for Medical Agentic AI Systems
Source quote
L186: Macro Risk │ 5.7% │ 4.8% │ 3.8% │ Macro Risk │ 20.9% │ 4.6%
2026DP-MixMin proposedmacro AUC+0.037dp-1Differentially Private Mixing of Public Datasets Improves Private Learning
Source quote
L553: every privacy budget we tested: +0.037, +0.032, +0.029 absolute macro AUC gain over uniform at
2026DP-MixMin proposedmacro AUC+0.033dp-1Differentially Private Mixing of Public Datasets Improves Private Learning
Source quote
L554: ϵ = 1, 2, 5 for CheXpert pretraining(Figure 2), and +0.033, +0.028, +0.024 for MIMIC-CXR. Tables 7
2026DP-MixMin proposedmacro AUC+0.032dp-2Differentially Private Mixing of Public Datasets Improves Private Learning
Source quote
L553: every privacy budget we tested: +0.037, +0.032, +0.029 absolute macro AUC gain over uniform at
2026DP-MixMin proposedmacro AUC+0.029dp-5Differentially Private Mixing of Public Datasets Improves Private Learning
Source quote
L553: every privacy budget we tested: +0.037, +0.032, +0.029 absolute macro AUC gain over uniform at
2026DP-MixMin proposedmacro AUC+0.028dp-2Differentially Private Mixing of Public Datasets Improves Private Learning
Source quote
L554: ϵ = 1, 2, 5 for CheXpert pretraining(Figure 2), and +0.033, +0.028, +0.024 for MIMIC-CXR. Tables 7
2026DP-MixMin proposedmacro AUC+0.024dp-5Differentially Private Mixing of Public Datasets Improves Private Learning
Source quote
L554: ϵ = 1, 2, 5 for CheXpert pretraining(Figure 2), and +0.033, +0.028, +0.024 for MIMIC-CXR. Tables 7
2025DenseNet trained on NIH-WA proposedPI Score3.31%split: test · backbone=DenseNet · training-data=NIH-WACheXwhatsApp: A Dataset for Exploring Challenges in the Diagnosis of Chest X-rays through Mobile Devices
Source quote
L206: 3.31 (79%)
2025ResNeXt trained on NIH-WA proposedOLS Score (GradCAM++)10.51split: test · backbone=ResNeXt · training-data=NIH-WA · attribution-method=GradCAM++CheXwhatsApp: A Dataset for Exploring Challenges in the Diagnosis of Chest X-rays through Mobile Devices
Source quote
L285: 10.51 (82%)
2025AT-CXR (LLM Router) proposed non-standard sliceAccuracy95.3%subset=balanced · coverage=100% · evaluation=five-foldAT-CXR: Uncertainty-Aware Agentic Triage for Chest X-rays
Source quote
L17: To address these gaps, we propose AT-CXR (Agentic Triage for Chest X-ray), an uncertainty-aware agentic framework designed to make autonomous, safe triage decisions under clinical resource and reliability constraints. AT-CXR treats triage as a stepwise policy over a fixed action set: given an initial assessment score and a distribution-fit signal, the router may invoke test-time augmentation to probe stability, consult a committee of experts, or escalate to a vision–language model. The policy can iterate and then either issue an automated label or abstain with a suggested label for human review. A folder watcher and auto-sorting complete an end-to-end pipeline, reducing cognitive load and aligning with clinical throughput. For interpretability, AT-CXR generates Class Activation Maps~\cite{zhou2016learning} that highlight suspicious regions alongside the triage outcome. We instantiate two router designs over the same inputs and action set: a deterministic rule-based router and an LLM-decided router. Evaluated on NIH ChestX-ray14~\cite{wang2017chestx} for pulmonary-edema triage, the LLM and rule-based routers achieve overall accuracies of 95.3% and 93.8%, respectively, at 100% coverage (including abstained-with-suggestion outputs). Both designs surpass strong zero-shot vision–language models and state-of-the-art supervised classifiers, achieving higher full-coverage accuracy and stronger selective-prediction performance, as reflected in lower AURC and reduced error at high coverage, while maintaining low latency and modest computational requirements that are compatible with clinical workflows. These results highlight the potential of uncertainty-aware agentic policies to enable safe and efficient CXR triage.
2025AT-CXR (Rule-Based Router) proposed non-standard sliceAccuracy93.8%subset=balanced · coverage=100% · evaluation=five-foldAT-CXR: Uncertainty-Aware Agentic Triage for Chest X-rays
Source quote
L17: To address these gaps, we propose AT-CXR (Agentic Triage for Chest X-ray), an uncertainty-aware agentic framework designed to make autonomous, safe triage decisions under clinical resource and reliability constraints. AT-CXR treats triage as a stepwise policy over a fixed action set: given an initial assessment score and a distribution-fit signal, the router may invoke test-time augmentation to probe stability, consult a committee of experts, or escalate to a vision–language model. The policy can iterate and then either issue an automated label or abstain with a suggested label for human review. A folder watcher and auto-sorting complete an end-to-end pipeline, reducing cognitive load and aligning with clinical throughput. For interpretability, AT-CXR generates Class Activation Maps~\cite{zhou2016learning} that highlight suspicious regions alongside the triage outcome. We instantiate two router designs over the same inputs and action set: a deterministic rule-based router and an LLM-decided router. Evaluated on NIH ChestX-ray14~\cite{wang2017chestx} for pulmonary-edema triage, the LLM and rule-based routers achieve overall accuracies of 95.3% and 93.8%, respectively, at 100% coverage (including abstained-with-suggestion outputs). Both designs surpass strong zero-shot vision–language models and state-of-the-art supervised classifiers, achieving higher full-coverage accuracy and stronger selective-prediction performance, as reflected in lower AURC and reduced error at high coverage, while maintaining low latency and modest computational requirements that are compatible with clinical workflows. These results highlight the potential of uncertainty-aware agentic policies to enable safe and efficient CXR triage.
2024ASG (ViT-based; Ours) proposedAUC79.5linear-probe · subset=1% data · backbone=ViTAnatomical Structure-Guided Medical Vision-Language Pre-training
Source quote
L180: Ours │ 79.5 │ 82.2 │ 83.6 │ 87.9 │ 89.0 │ 89.0
2024ViT-B-LR (LRFL) proposedmean AUC (mAUC)83.4%fine-tuned · epochs=75 · backbone=ViT-B · pretraining=MAELearning Low-Rank Feature for Thorax Disease Classification
Source quote
L252: For example, we use ViT-B model pre-trained on 266,340 chest X-rays with Masked Autoencoders (MAE) \citep{xiao2023delving}. The pre-trained ViT-B network is fine-tuned on the NIH ChestX-ray14 dataset and achieves a mean AUC of 83.0. Next, we fine-tune ViT-B with low-rank regularization for another 75 epochs. The low-rank model, denoted as ViT-B-LR, achieves a mean AUC of 83.4. It is observed that all low-rank models achieve improvement in mean AUC compared to the corresponding base models. ViT-S-LR improves its base model by a mean AUC of 0.4%. Similar improvements are observed for CNN-based models as well. For example, ResNet-50-LR improves its base model by a mean AUC of 0.40%.
2024Proposed region-to-region self-attention method proposedAUC0.798training=from-scratch · pretrained-weights=noneExplainable Transformer Prototypes for Medical Diagnoses
Source quote
L79: Ours │ 0.752 │ 0.873 │ 0.817 │ 0.696 │ 0.784 │ 0.738 │ 0.699 │ 0.850 │ 0.734 │ 0.837 │ 0.893 │ 0.807 │ 0.765 │ 0.928 │ 0.798
2024LoRA with foundation models proposedAUROC80.6%peft · labeled-data=1%Less Could Be Better: Parameter-efficient Fine-tuning Advances Medical Vision Foundation Models
Source quote
L15: 80.6% using 1% labeled data on NIH ChestX-ray14. We hope this study can evoke more attention from the community in the use of PEFT for transfer learning on medical imaging tasks. Code and models are available at https://github.com/RL4M/MED-PEFT.
2024CIPL proposedMean AUC0.828split: testCross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and Interpretation
Source quote
L541: As can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885,
2024CIPL proposedMean weakly-supervised localization accuracy (thresholded IoU accuracy)0.78IoU-threshold=0.1Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and Interpretation
Source quote
L652: CIPL │ 0.69 │ 1.00 │ 0.71 │ 0.91 │ 0.85 │ 0.58 │ 0.98 │ 0.48 │ 0.78
2023FedLSM proposedAUC0.791federated-learning · runs=3 · clients=8 · classes-per-client=3Scale Federated Learning for Label Set Mismatch in Medical Image Classification
Source quote
L143: Ours │ 0.791 │ 0.960 │ 0.846 │ 0.713 │ 0.763 │ 0.699
2023proposed causal approach proposedMean AUC0.857split: test · backbone=ResNet101Chest X-ray Image Classification: A Causal Perspective
Source quote
L151: Mean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864)
2023M-FLAG proposedAUC62.2%fine-tuned · labeled-data=1%M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry Optimization
Source quote
L112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7
2023Proposed instrumental variable learning framework proposedMean AUC0.867Average across 14 thoracic diseases; no split condition is specified in the cited result.Instrumental Variable Learning for Chest X-ray Classification
Source quote
L183: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.867
2023DGFN proposedMean AUC0.850split: testDeep reinforcement learning framework for thoracic diseases classification via prior knowledge guidance
Source quote
L291: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873)
2023ShorT (age-head gradient scaling) proposedSpearman rank correlation (age MAE vs separation)-0.224target=effusion · dataset_variant=originalDetecting shortcut learning for fair medical AI using shortcut testing
Source quote
L57: In order to quantify the statistical dependence of unfairness on age encoding - a signature of shortcut learning - we calculated the Spearman rank correlation between these two variables (Figure 4). For the original dataset (Figure 4a), there was a small but statistically significant correlation between encoding and unfairness (⍴=-0.224, p=0.0156), indicating the presence of shortcut learning. This was amplified in models trained on the biased dataset (Figure 4b), indicating the presence of significantly stronger shortcutting when training with this biased dataset (⍴=-0.668, p=8.11e-17). Conversely, the correlation coefficient in the balanced dataset was not significant (Figure 4c, ⍴=0.116, p=0.218), indicating no systematic impact of age encoding on fairness in models trained on this dataset (for details, see Supplementary
2023ShorT (age-head gradient scaling) proposedSpearman rank correlation (age MAE vs separation)-0.668target=effusion · dataset_variant=biasedDetecting shortcut learning for fair medical AI using shortcut testing
Source quote
L57: In order to quantify the statistical dependence of unfairness on age encoding - a signature of shortcut learning - we calculated the Spearman rank correlation between these two variables (Figure 4). For the original dataset (Figure 4a), there was a small but statistically significant correlation between encoding and unfairness (⍴=-0.224, p=0.0156), indicating the presence of shortcut learning. This was amplified in models trained on the biased dataset (Figure 4b), indicating the presence of significantly stronger shortcutting when training with this biased dataset (⍴=-0.668, p=8.11e-17). Conversely, the correlation coefficient in the balanced dataset was not significant (Figure 4c, ⍴=0.116, p=0.218), indicating no systematic impact of age encoding on fairness in models trained on this dataset (for details, see Supplementary
2023ShorT (age-head gradient scaling) proposedSpearman rank correlation (age MAE vs separation)0.116target=effusion · dataset_variant=balancedDetecting shortcut learning for fair medical AI using shortcut testing
Source quote
L57: In order to quantify the statistical dependence of unfairness on age encoding - a signature of shortcut learning - we calculated the Spearman rank correlation between these two variables (Figure 4). For the original dataset (Figure 4a), there was a small but statistically significant correlation between encoding and unfairness (⍴=-0.224, p=0.0156), indicating the presence of shortcut learning. This was amplified in models trained on the biased dataset (Figure 4b), indicating the presence of significantly stronger shortcutting when training with this biased dataset (⍴=-0.668, p=8.11e-17). Conversely, the correlation coefficient in the balanced dataset was not significant (Figure 4c, ⍴=0.116, p=0.218), indicating no systematic impact of age encoding on fairness in models trained on this dataset (for details, see Supplementary
2023E-D6 proposed non-standard sliceSensitivity76.7%split: test · subset=curated external subset · training-data-exclusion=very subtle and extremely subtle JSRT nodules · false-positives-per-image=7.6Full-resolution Lung Nodule Segmentation from Chest X-ray Images using Residual Encoder-Decoder Networks
Source quote
L1061: In external testing, E-D6 provided an excellent generalization result when very subtle and extremely subtle nodules were excluded from the JSRT training data. Internally, at 1024 x 1024 pixels, E-D6 achieved a sensitivity of 83.6% with 8.3 false positives per image. Externally E-D6 achieved a sensitivity of 76.7% at 7.6 false positives per image.
2023MaCo proposedAUC77.3%0-shotEnhancing representation in radiography-reports foundation model: a granular alignment algorithm using masked contrastive learning
Source quote
L326: MaCo (Ours) │ 77.3 │ 88.6 │ 90.4
2022RGT (Radiomics-Guided Transformer) proposedMean AUC0.839runs=3Radiomics-Guided Global-Local transformer for weakly supervised pathology localization in chest X-Rays
Source quote
L197: RGT (ours) │ 0.80 │ 0.92 │ 0.78 │ 0.86 │ 0.88 │ 0.88 │ 0.79 │ 0.81 │ 0.839
2022MAE-pretrained ViT-S/16 proposedmAUC (mean AUC over 14 diseases)82.3%split: test · fine-tuned · params=0.3M · backbone=ViT-S/16 · pretraining-data=0.3M X-raysDelving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L370: MAE │ ViT-S/16 │ 82.3
2022MAE-pretrained DenseNet-121 (DN121) proposedmAUC81.2%split: test · fine-tuned · params=0.3M · backbone=DenseNet-121 · pretraining-data=0.3M X-raysDelving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L369: MAE │ DN121 │ 81.2
2022KAFAL proposedmAUC63.61split: test · alpha=0.1 · clients=5 · labeled-data=15% · client-update-fraction=80%Knowledge-Aware Federated Active Learning with Non-IID Data
Source quote
L389: \bf KAFAL (ours) │ 63.61 │ 64.48
2022KAFAL proposedmAUC64.48split: test · alpha=0.1 · clients=5 · labeled-data=20% · client-update-fraction=80%Knowledge-Aware Federated Active Learning with Non-IID Data
Source quote
L389: \bf KAFAL (ours) │ 63.61 │ 64.48
2022Clinical-BERT (Ours; proposed pre-trained model) proposedMean AUC0.8450split: testClinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports Generation
Source quote
L544: 0.8450
2022NIH DenseNet121 model proposedk-robust accuracy (k=1)13.78%k=1 · model=DenseNet121 · attack=untargetedOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L279: \multirow{5}{*}{k=1} │ NIH │ 13.78 │ 1.38 │ 9.66 │ 8.47 │ 7.12 │ 2.25
2022NIH DenseNet121 model proposedk-robust accuracy (k=1)2.69%k=1 · loss=BCE · model=DenseNet121 · attack=targetedOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L433: \multirow{7}{*}{BCE} │ k=1 \uparrow │ 2.69 │ 1.19 │ 0.19 │ 0.69 │ 0 │ 3
2022AllD DenseNet121 model proposedk-robust accuracy (k=3)32.12%k=3 · model=DenseNet121 · attack=untargeted · training-dataset=AllDOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L291: AllD │ 21.69 │ 6.34 │ 35.38 │ 27.12 │ 27.34 │ 32.12
2022AllD DenseNet121 model proposedk-robust accuracy (k=3)11.12%k=3 · loss=BCE · model=DenseNet121 · attack=targeted · training-dataset=AllDOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L434: k=3 \uparrow │ 12.43 │ 8.19 │ 16.5 │ 1.75 │ 0 │ 11.12
2021CheXDet proposedJAFROC-FOM0.55split: test · subset=880 frontal radiographs · finding=pneumothoraxRethinking annotation granularity for overcoming deep shortcut learning: A retrospective study on chest radiographs
Source quote
L38: CheXDet achieved higher lesion localization performance than CheXNet for most abnormalities on all datasets, such as in detecting pneumothorax on the internal testing sets (CheXDet jacknife alternative free-respnse ROCfigure of merit [JAFROC-FOM]: 0.87, CheXNet JAFROC-FOM: 0.13; p<.001) and the external NIH-ChestXray14 dataset (CheXDet JAFROC-FOM: 0.55, CheXNet JAFROC-FOM: 0.04; p<.001).
2021CXR-ML-GZSL (OUR_e2e) proposedprecision@2 (p@k, k=2)0.33split: test · generalized-zero-shot · prediction=top-2Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021CXR-ML-GZSL (OUR_e2e) proposedAUROC for unseen classes (U)0.66split: test · generalized-zero-shot · class-set=unseenMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021CXR-ML-GZSL (OUR_e2e) proposedharmonic mean AUROC (H) across seen and unseen classes0.72split: test · generalized-zero-shotMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021XProtoNet (ResNet-50) proposedMean AUC0.820split: test · backbone=ResNet-50XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792.
2021XProtoNet (DenseNet-121) proposedMean AUC0.822split: test · backbone=DenseNet-121XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822.
2021XProtoNet (no additional supervision) proposedMean AUC0.85split: val · validation=five-fold cross-validation · supervision=no bounding-box supervisionXProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L280: XProtoNet (Ours) │ 0.83 │ 0.91 │ 0.89 │ 0.72 │ 0.87 │ 0.82 │ 0.76 │ 0.90 │ 0.80 │ 0.90 │ 0.94 │ 0.82 │ 0.82 │ 0.92 │ 0.85
2020CIAN-CEN proposedMean disease localization accuracy0.67split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1Contralaterally Enhanced Networks for Thoracic Disease Detection
Source quote
L225: CIAN-CEN │ 0.71 │ 0.91 │ 0.74 │ 0.85 │ 0.79 │ 0.47 │ 0.40 │ 0.50 │ 0.67
2020SGL proposedMean disease localization accuracy0.66IoU-threshold=0.1 · classification-threshold=0.5Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L232: SGL (Ours) │ 0.67 │ 0.94 │ 0.67 │ 0.81 │ 0.71 │ 0.41 │ 0.66 │ 0.43 │ 0.66
2020ChexRadiNet proposed non-standard sliceMean disease localization score0.679IoU_threshold=0.1 · ground_truth_bounding_boxes=not usedUsing Radiomics as Prior Knowledge for Thorax Disease Classification and Localization in Chest X-rays
Source quote
L146: ChexRadiNet │ 0.72 │ 0.96 │ 0.81 │ 0.88 │ 0.67 │ 0.33 │ 0.59 │ 0.47 │ 0.679
2020ChexRadiNet proposed non-standard sliceMean disease localization score0.055IoU_threshold=0.7 · ground_truth_bounding_boxes=not usedUsing Radiomics as Prior Knowledge for Thorax Disease Classification and Localization in Chest X-rays
Source quote
L158: ChexRadiNet │ 0.02 │ 0.21 │ 0.04 │ 0.02 │ 0.07 │ 0.01 │ 0.03 │ 0.04 │ 0.055
2020Proposed Deep Perceptual Autoencoder proposed non-standard sliceROC AUC0.926subset=abnormal chest X-raysAnomaly Detection in Medical Imaging With Deep Perceptual Autoencoders
Source quote
L60: the proposed solution achieves 0.943 ROC AUC in the detection of metastases in H\ │ E stained images of lymph nodes (Camelyon16 dataset~\cite{bejnordi2017diagnostic}), and 0.926 in the detection of abnormal chest X-rays (subset of NIH dataset~\cite{wang2017chestx}). This outperforms SOTA methods.
2019proposed generative adversarial one-class model (U+D+E) proposed non-standard sliceAUC0.841split: test · runs=5 · training-data=normal CXRs onlyAbnormal Chest X-ray Identification With Generative Adversarial One-Class Classifier
Source quote
L111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage.
2019proposed generative adversarial one-class model (U+D+E) proposed non-standard sliceAUC0.802runs=5 · subset=lung opacities · training-data=normal CXRs onlyAbnormal Chest X-ray Identification With Generative Adversarial One-Class Classifier
Source quote
L111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage.
2018Proposed model with a 1×1 capsule convolutional layer proposedAverage AUC0.775split: testDynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area Localization
Source quote
L102: Average │ 0.738 │ 0.761 │ 0.775 │ 0.626