NIH ChestX-ray14
41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API
Also indexed as: nih-chestx-ray14
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | proposed causal approach SOTA frontier | 0.857 | 2023-05-01 | backbone=ResNet101 · Official data split; AUC evaluated on the whole test set. ResNet101 backbone. | Chest X-ray Image Classification: A Causal PerspectiveSource quoteMean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2 | DGFN SOTA frontier | 0.85 | 2023-01-01 | Official split; test-set performance averaged over 14 thoracic diseases, as shown in … | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 3 | Clinical-BERT (Ours; proposed pre-trained model) SOTA frontier | 0.845 | 2022-01-01 | NIH ChestX-ray14 official split; radiograph diagnosis evaluated by AUC for pathology,… | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quote0.8450 |
| 4 | CIPL | 0.828 | 2025-01-01 | Multi-label thoracic disease classification; results on the official dataset split, w… | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteAs can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 5 | XProtoNet (DenseNet-121) SOTA frontier (+1 variant) | 0.822 | 2021-01-01 | backbone=DenseNet-121 · Official-split comparison with Guan et al.; single DenseNet-121 comparator. | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteCompared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 6 | Proposed model with a 1×1 capsule convolutional layer SOTA frontier | 0.775 | 2018-08-01 | Official training/test split; trained on the chest X-ray dataset without additional t… | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteAverage │ 0.738 │ 0.761 │ 0.775 │ 0.626 |
| 7 | GTDA error estimation (+1 variant) | 0.75 | 2023-01-01 | Finding incorrect normal-vs-abnormal test labels among 810 images with expert labels;… | Topological structure of complex predictionsSource quoteFor simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
Showing 18 of 18 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.484 | split: test-evaluation-half | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL303: best (Fig. 5a): AUROCf was 0.484 (0.468–0.502) for Dense- |
| 2026 | Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard slice | AUROCf (failure-detection AUROC) | 0.524 | split: test-evaluation-half · backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL304: Net-121 and 0.524 (0.509–0.539) for ViT-B/16, against |
| 2026 | Absolute decision margin |m|, DenseNet-121 baseline non-standard slice | AUROCf (failure-detection AUROC) | 0.646 | split: test-evaluation-half | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL305: 0.646 (0.632–0.662) and 0.660 (0.647–0.673) for the abso- |
| 2026 | Absolute decision margin |m|, ViT-B/16 baseline non-standard slice | AUROCf (failure-detection AUROC) | 0.660 | split: test-evaluation-half · backbone=ViT-B/16 | Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studySource quoteL305: 0.646 (0.632–0.662) and 0.660 (0.647–0.673) for the abso- |
| 2026 | No Adapt. baseline | mean AUROC | 64.6 | Main results table; seventh value in the target-domain block (aggregate). | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL139: No Adapt. │ 56.6 │ 62.3 │ 67.4 │ 67.4 │ 64.1 │ 69.7 │ 64.6 │ 74.3 │ 71.7 │ 79.4 │ 80.8 │ 71.2 │ 78.3 │ 76.0 |
| 2026 | TENT baseline | mean AUROC | 54.0 | split: test · test-time-adaptation | Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray DiagnosisSource quoteL141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4 |
| 2025 | 9-member Deep Ensemble (DE) | Average AUROC | 0.8559 | Reported average for the 14 thoracic diseases; the ensemble uses diverse architectural … | Enhancing Multi-Label Thoracic Disease Diagnosis with Deep Ensemble-Based Uncertainty QuantificationSource quoteL254: The synthesis of diverse models into the final Deep Ensemble successfully overcame these bottlenecks, achieving superior metrics compared to both the reproduced DannyNet baseline and the original paper’s reported results. The DE achieved an average AUROC of 0.8559, representing a consistent improvement of 0.0045 (0.53%) over the best single model (0.8514). This gain confirms the architectural validity of the DE approach. The combined ROC curves, presented in Figure \ref{fig:roc_curves}, provide a visual validation of the robust classification performance, illustrating the strong true positive rates relative to false positive rates across all 14 classes. |
| 2024 | LoRA with foundation models proposed | AUROC | 80.6% | peft · labeled-data=1% | Less Could Be Better: Parameter-efficient Fine-tuning Advances Medical Vision Foundation ModelsSource quoteL15: 80.6% using 1% labeled data on NIH ChestX-ray14. We hope this study can evoke more attention from the community in the use of PEFT for transfer learning on medical imaging tasks. Code and models are available at https://github.com/RL4M/MED-PEFT. |
| 2024 | ConVIRT (None) baseline | AUROC | 71.7% | 1 · training-data=1% | BenchX: A Unified Benchmark Framework for Medical Vision-Language Pretraining on Chest X-RaysSource quoteL280: ConVIRT │ 71.7 │ 76.9 (\uparrow) │ 74.5 (\downarrow) │ 77.0 (\uparrow) |
| 2024 | ConVIRT (All: LN, TNI, and DLR) baseline | AUROC | 77.0% | 1 · configuration=LN+TNI+DLR · training-data=1% | BenchX: A Unified Benchmark Framework for Medical Vision-Language Pretraining on Chest X-RaysSource quoteL280: ConVIRT │ 71.7 │ 76.9 (\uparrow) │ 74.5 (\downarrow) │ 77.0 (\uparrow) |
| 2021 | CXR-ML-GZSL (OUR_e2e) proposed | AUROC for unseen classes (U) | 0.66 | split: test · generalized-zero-shot · class-set=unseen | Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest RadiographsSource quoteL137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72 |
| 2021 | CXR-ML-GZSL (OUR_e2e) proposed | harmonic mean AUROC (H) across seen and unseen classes | 0.72 | split: test · generalized-zero-shot | Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest RadiographsSource quoteL137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72 |
| 2021 | MLZSL baseline | AUROC for unseen classes (U) | 0.54 | split: test · generalized-zero-shot · class-set=unseen | Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest RadiographsSource quoteL135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62 |
| 2021 | MLZSL baseline | harmonic mean AUROC (H) across seen and unseen classes | 0.62 | split: test · generalized-zero-shot | Multi-Label Generalized Zero Shot Learning for the Classification of Disease in Chest RadiographsSource quoteL135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62 |
| 2021 | CheXNet (DenseNet121) baseline | AUROC | 0.760 | split: test · test-images=420 · patient-disjoint=true | Advancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative AnalysisSource quoteL109: 0.760 |
| 2021 | MUXConv (Multiplexed Convolutions) baseline | AUROC | 0.841 | Pneumonia detection on the NIH dataset; reported as using the same dataset as Rajpurkar… | Advancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative AnalysisSource quoteL118: 0.841 |
| 2021 | NSGANetV1 baseline | AUROC | 0.846 | Pneumonia detection; evaluated on NIH without model modifications or hyperparameter tun… | Advancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative AnalysisSource quoteL123: 0.846 |
| 2020 | Proposed Deep Perceptual Autoencoder proposed non-standard slice | ROC AUC | 0.926 | subset=abnormal chest X-rays | Anomaly Detection in Medical Imaging With Deep Perceptual AutoencodersSource quoteL60: the proposed solution achieves 0.943 ROC AUC in the detection of metastases in H\ │ E stained images of lymph nodes (Camelyon16 dataset~\cite{bejnordi2017diagnostic}), and 0.926 in the detection of abnormal chest X-rays (subset of NIH dataset~\cite{wang2017chestx}). This outperforms SOTA methods. |