NIH ChestX-ray14

41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API

Also indexed as: nih-chestx-ray14

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.80.9201920222025Proposed model with a 1×1 capsule convolutional layer: 0.775 (2018)XProtoNet (ResNet-50): 0.82 (2021)XProtoNet (DenseNet-121): 0.822 (2021)Clinical-BERT (Ours; proposed pre-trained model): 0.845 (2022)Self confidence: 0.6 (2023)GTDA error estimation: 0.75 (2023)DGFN: 0.85 (2023)proposed causal approach: 0.857 (2023)CIPL: 0.828 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.484split: test-evaluation-halfCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L303: best (Fig. 5a): AUROCf was 0.484 (0.468–0.502) for Dense-
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.524split: test-evaluation-half · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L304: Net-121 and 0.524 (0.509–0.539) for ViT-B/16, against
2026Absolute decision margin |m|, DenseNet-121 baseline non-standard sliceAUROCf (failure-detection AUROC)0.646split: test-evaluation-halfCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L305: 0.646 (0.632–0.662) and 0.660 (0.647–0.673) for the abso-
2026Absolute decision margin |m|, ViT-B/16 baseline non-standard sliceAUROCf (failure-detection AUROC)0.660split: test-evaluation-half · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L305: 0.646 (0.632–0.662) and 0.660 (0.647–0.673) for the abso-
2026No Adapt. baselinemean AUROC64.6Main results table; seventh value in the target-domain block (aggregate).Leveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L139: No Adapt. │ 56.6 │ 62.3 │ 67.4 │ 67.4 │ 64.1 │ 69.7 │ 64.6 │ 74.3 │ 71.7 │ 79.4 │ 80.8 │ 71.2 │ 78.3 │ 76.0
2026TENT baselinemean AUROC54.0split: test · test-time-adaptationLeveraging Pathology Co-occurrence for Test-Time Adaptation in Chest X-Ray Diagnosis
Source quote
L141: TENT │ 50.1 │ 50.1 │ 53.5 │ 55.3 │ 52.0 │ 63.0 │ 54.0 │ 77.7 │ 76.5 │ 80.6 │ 83.2 │ 65.5 │ 81.1 │ 77.4
20259-member Deep Ensemble (DE)Average AUROC0.8559Reported average for the 14 thoracic diseases; the ensemble uses diverse architectural …Enhancing Multi-Label Thoracic Disease Diagnosis with Deep Ensemble-Based Uncertainty Quantification
Source quote
L254: The synthesis of diverse models into the final Deep Ensemble successfully overcame these bottlenecks, achieving superior metrics compared to both the reproduced DannyNet baseline and the original paper’s reported results. The DE achieved an average AUROC of 0.8559, representing a consistent improvement of 0.0045 (0.53%) over the best single model (0.8514). This gain confirms the architectural validity of the DE approach. The combined ROC curves, presented in Figure \ref{fig:roc_curves}, provide a visual validation of the robust classification performance, illustrating the strong true positive rates relative to false positive rates across all 14 classes.
2024LoRA with foundation models proposedAUROC80.6%peft · labeled-data=1%Less Could Be Better: Parameter-efficient Fine-tuning Advances Medical Vision Foundation Models
Source quote
L15: 80.6% using 1% labeled data on NIH ChestX-ray14. We hope this study can evoke more attention from the community in the use of PEFT for transfer learning on medical imaging tasks. Code and models are available at https://github.com/RL4M/MED-PEFT.
2024ConVIRT (None) baselineAUROC71.7%1 · training-data=1%BenchX: A Unified Benchmark Framework for Medical Vision-Language Pretraining on Chest X-Rays
Source quote
L280: ConVIRT │ 71.7 │ 76.9 (\uparrow) │ 74.5 (\downarrow) │ 77.0 (\uparrow)
2024ConVIRT (All: LN, TNI, and DLR) baselineAUROC77.0%1 · configuration=LN+TNI+DLR · training-data=1%BenchX: A Unified Benchmark Framework for Medical Vision-Language Pretraining on Chest X-Rays
Source quote
L280: ConVIRT │ 71.7 │ 76.9 (\uparrow) │ 74.5 (\downarrow) │ 77.0 (\uparrow)
2021CXR-ML-GZSL (OUR_e2e) proposedAUROC for unseen classes (U)0.66split: test · generalized-zero-shot · class-set=unseenMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021CXR-ML-GZSL (OUR_e2e) proposedharmonic mean AUROC (H) across seen and unseen classes0.72split: test · generalized-zero-shotMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021MLZSL baselineAUROC for unseen classes (U)0.54split: test · generalized-zero-shot · class-set=unseenMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62
2021MLZSL baselineharmonic mean AUROC (H) across seen and unseen classes0.62split: test · generalized-zero-shotMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L135: MLZSL (\citeyear{Lee_2018_CVPR}) │ 0.20 │ 0.19 │ 0.16 │ 0.30 │ 0.17 │ 0.20 │ 0.72 │ 0.54 │ 0.62
2021CheXNet (DenseNet121) baselineAUROC0.760split: test · test-images=420 · patient-disjoint=trueAdvancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative Analysis
Source quote
L109: 0.760
2021MUXConv (Multiplexed Convolutions) baselineAUROC0.841Pneumonia detection on the NIH dataset; reported as using the same dataset as Rajpurkar…Advancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative Analysis
Source quote
L118: 0.841
2021NSGANetV1 baselineAUROC0.846Pneumonia detection; evaluated on NIH without model modifications or hyperparameter tun…Advancement of Deep Learning in Pneumonia and Covid-19 Classification and Localization: A Qualitative and Quantitative Analysis
Source quote
L123: 0.846
2020Proposed Deep Perceptual Autoencoder proposed non-standard sliceROC AUC0.926subset=abnormal chest X-raysAnomaly Detection in Medical Imaging With Deep Perceptual Autoencoders
Source quote
L60: the proposed solution achieves 0.943 ROC AUC in the detection of metastases in H\ │ E stained images of lymph nodes (Camelyon16 dataset~\cite{bejnordi2017diagnostic}), and 0.926 in the detection of abnormal chest X-rays (subset of NIH dataset~\cite{wang2017chestx}). This outperforms SOTA methods.