NIH ChestX-ray14

41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API

Also indexed as: nih-chestx-ray14

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.80.9201920222025Proposed model with a 1×1 capsule convolutional layer: 0.775 (2018)XProtoNet (ResNet-50): 0.82 (2021)XProtoNet (DenseNet-121): 0.822 (2021)Clinical-BERT (Ours; proposed pre-trained model): 0.845 (2022)Self confidence: 0.6 (2023)GTDA error estimation: 0.75 (2023)DGFN: 0.85 (2023)proposed causal approach: 0.857 (2023)CIPL: 0.828 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 6 of 6 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Anatomical enrichment E (Grad-CAM), DenseNet-121 proposed non-standard sliceAUROCf (failure-detection AUROC)0.484split: test-evaluation-halfCan saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L303: best (Fig. 5a): AUROCf was 0.484 (0.468–0.502) for Dense-
2026Anatomical enrichment E (Grad-CAM), ViT-B/16 proposed non-standard sliceAUROCf (failure-detection AUROC)0.524split: test-evaluation-half · backbone=ViT-B/16Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study
Source quote
L304: Net-121 and 0.524 (0.509–0.539) for ViT-B/16, against
2024LoRA with foundation models proposedAUROC80.6%peft · labeled-data=1%Less Could Be Better: Parameter-efficient Fine-tuning Advances Medical Vision Foundation Models
Source quote
L15: 80.6% using 1% labeled data on NIH ChestX-ray14. We hope this study can evoke more attention from the community in the use of PEFT for transfer learning on medical imaging tasks. Code and models are available at https://github.com/RL4M/MED-PEFT.
2021CXR-ML-GZSL (OUR_e2e) proposedAUROC for unseen classes (U)0.66split: test · generalized-zero-shot · class-set=unseenMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2021CXR-ML-GZSL (OUR_e2e) proposedharmonic mean AUROC (H) across seen and unseen classes0.72split: test · generalized-zero-shotMulti-Label Generalized Zero Shot Learning for the Classification of Disease in Chest Radiographs
Source quote
L137: OUR-e2e │ 0.36 │ 0.33 │ 0.32 │ 0.47 │ 0.28 │ 0.34 │ 0.79 │ 0.66 │ 0.72
2020Proposed Deep Perceptual Autoencoder proposed non-standard sliceROC AUC0.926subset=abnormal chest X-raysAnomaly Detection in Medical Imaging With Deep Perceptual Autoencoders
Source quote
L60: the proposed solution achieves 0.943 ROC AUC in the detection of metastases in H\ │ E stained images of lymph nodes (Camelyon16 dataset~\cite{bejnordi2017diagnostic}), and 0.926 in the detection of abnormal chest X-rays (subset of NIH dataset~\cite{wang2017chestx}). This outperforms SOTA methods.