NIH ChestX-ray14
41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API
Also indexed as: nih-chestx-ray14
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | proposed causal approach SOTA frontier | 0.857 | 2023-05-01 | backbone=ResNet101 · Official data split; AUC evaluated on the whole test set. ResNet101 backbone. | Chest X-ray Image Classification: A Causal PerspectiveSource quoteMean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2 | DGFN SOTA frontier | 0.85 | 2023-01-01 | Official split; test-set performance averaged over 14 thoracic diseases, as shown in … | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 3 | Clinical-BERT (Ours; proposed pre-trained model) SOTA frontier | 0.845 | 2022-01-01 | NIH ChestX-ray14 official split; radiograph diagnosis evaluated by AUC for pathology,… | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quote0.8450 |
| 4 | CIPL | 0.828 | 2025-01-01 | Multi-label thoracic disease classification; results on the official dataset split, w… | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteAs can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 5 | XProtoNet (DenseNet-121) SOTA frontier (+1 variant) | 0.822 | 2021-01-01 | backbone=DenseNet-121 · Official-split comparison with Guan et al.; single DenseNet-121 comparator. | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteCompared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 6 | Proposed model with a 1×1 capsule convolutional layer SOTA frontier | 0.775 | 2018-08-01 | Official training/test split; trained on the chest X-ray dataset without additional t… | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteAverage │ 0.738 │ 0.761 │ 0.775 │ 0.626 |
| 7 | GTDA error estimation (+1 variant) | 0.75 | 2023-01-01 | Finding incorrect normal-vs-abnormal test labels among 810 images with expert labels;… | Topological structure of complex predictionsSource quoteFor simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
Showing 42 of 42 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | VIVID-Med proposed | macro-AUC | 0.7225 | 0-shot | VIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTsSource quoteL4: Vision-language pretraining has driven significant progress in medical image analysis. However, current methods typically supervise visual encoders using one-hot labels or free-form text, neither of which effectively captures the complex semantic relationships among clinical findings. In this study, we introduce VIVID-Med, a novel framework that leverages a frozen large language model (LLM) as a structured semantic teacher to pretrain medical vision transformers (ViTs). VIVID-Med translates clinical findings into verifiable JSON field-state pairs via a Unified Medical Schema (UMS), utilizing answerability-aware masking to focus optimization. It then employs Structured Prediction Decomposition (SPD) to partition cross-attention into orthogonality-regularized query groups, extracting complementary visual aspects. Crucially, the LLM is discarded post-training, yielding a lightweight, deployable ViT-only backbone. We evaluated VIVID-Med across multiple settings: on CheXpert linear probing, it achieves a macro-AUC of 0.8588, outperforming BiomedCLIP by {+}6.65 points while using 500× less data. It also demonstrates robust zero-shot cross-domain transfer to NIH ChestX-ray14 (0.7225 macro-AUC) and strong cross-modality generalization to CT, achieving 0.8413 AUC on LIDC-IDRI lung nodule classification and 0.9969 macro-AUC on OrganAMNIST 11-organ classification. VIVID-Med offers a highly efficient, scalable alternative to deploying resource-heavy vision-language models in clinical settings. |
| 2026 | DP-MixMin proposed | macro AUC | +0.037 | dp-1 | Differentially Private Mixing of Public Datasets Improves Private LearningSource quoteL553: every privacy budget we tested: +0.037, +0.032, +0.029 absolute macro AUC gain over uniform at |
| 2026 | DP-MixMin proposed | macro AUC | +0.033 | dp-1 | Differentially Private Mixing of Public Datasets Improves Private LearningSource quoteL554: ϵ = 1, 2, 5 for CheXpert pretraining(Figure 2), and +0.033, +0.028, +0.024 for MIMIC-CXR. Tables 7 |
| 2026 | DP-MixMin proposed | macro AUC | +0.032 | dp-2 | Differentially Private Mixing of Public Datasets Improves Private LearningSource quoteL553: every privacy budget we tested: +0.037, +0.032, +0.029 absolute macro AUC gain over uniform at |
| 2026 | DP-MixMin proposed | macro AUC | +0.029 | dp-5 | Differentially Private Mixing of Public Datasets Improves Private LearningSource quoteL553: every privacy budget we tested: +0.037, +0.032, +0.029 absolute macro AUC gain over uniform at |
| 2026 | DP-MixMin proposed | macro AUC | +0.028 | dp-2 | Differentially Private Mixing of Public Datasets Improves Private LearningSource quoteL554: ϵ = 1, 2, 5 for CheXpert pretraining(Figure 2), and +0.033, +0.028, +0.024 for MIMIC-CXR. Tables 7 |
| 2026 | DP-MixMin proposed | macro AUC | +0.024 | dp-5 | Differentially Private Mixing of Public Datasets Improves Private LearningSource quoteL554: ϵ = 1, 2, 5 for CheXpert pretraining(Figure 2), and +0.033, +0.028, +0.024 for MIMIC-CXR. Tables 7 |
| 2024 | ASG (ViT-based; Ours) proposed | AUC | 79.5 | linear-probe · subset=1% data · backbone=ViT | Anatomical Structure-Guided Medical Vision-Language Pre-trainingSource quoteL180: Ours │ 79.5 │ 82.2 │ 83.6 │ 87.9 │ 89.0 │ 89.0 |
| 2024 | ViT-B-LR (LRFL) proposed | mean AUC (mAUC) | 83.4% | fine-tuned · epochs=75 · backbone=ViT-B · pretraining=MAE | Learning Low-Rank Feature for Thorax Disease ClassificationSource quoteL252: For example, we use ViT-B model pre-trained on 266,340 chest X-rays with Masked Autoencoders (MAE) \citep{xiao2023delving}. The pre-trained ViT-B network is fine-tuned on the NIH ChestX-ray14 dataset and achieves a mean AUC of 83.0. Next, we fine-tune ViT-B with low-rank regularization for another 75 epochs. The low-rank model, denoted as ViT-B-LR, achieves a mean AUC of 83.4. It is observed that all low-rank models achieve improvement in mean AUC compared to the corresponding base models. ViT-S-LR improves its base model by a mean AUC of 0.4%. Similar improvements are observed for CNN-based models as well. For example, ResNet-50-LR improves its base model by a mean AUC of 0.40%. |
| 2024 | Proposed region-to-region self-attention method proposed | AUC | 0.798 | training=from-scratch · pretrained-weights=none | Explainable Transformer Prototypes for Medical DiagnosesSource quoteL79: Ours │ 0.752 │ 0.873 │ 0.817 │ 0.696 │ 0.784 │ 0.738 │ 0.699 │ 0.850 │ 0.734 │ 0.837 │ 0.893 │ 0.807 │ 0.765 │ 0.928 │ 0.798 |
| 2024 | CIPL proposed | Mean AUC | 0.828 | split: test | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteL541: As can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 2024 | MGCA (ViT-based) baseline | AUC | 78.9 | linear-probe · subset=1% data · backbone=ViT | Anatomical Structure-Guided Medical Vision-Language Pre-trainingSource quoteL176: 78.9 │ 82.1 │ 83.5 │ 88.8 │ 89.1 │ 89.7 |
| 2024 | ViT-B baseline | mean AUC (mAUC) | 83.0% | fine-tuned · backbone=ViT-B · pretraining=MAE | Learning Low-Rank Feature for Thorax Disease ClassificationSource quoteL252: For example, we use ViT-B model pre-trained on 266,340 chest X-rays with Masked Autoencoders (MAE) \citep{xiao2023delving}. The pre-trained ViT-B network is fine-tuned on the NIH ChestX-ray14 dataset and achieves a mean AUC of 83.0. Next, we fine-tune ViT-B with low-rank regularization for another 75 epochs. The low-rank model, denoted as ViT-B-LR, achieves a mean AUC of 83.4. It is observed that all low-rank models achieve improvement in mean AUC compared to the corresponding base models. ViT-S-LR improves its base model by a mean AUC of 0.4%. Similar improvements are observed for CNN-based models as well. For example, ResNet-50-LR improves its base model by a mean AUC of 0.40%. |
| 2024 | XprotoNet, DenseNet baseline | AUC | 0.822 | backbone=DenseNet · pretrained-weights=ImageNet-1000 | Explainable Transformer Prototypes for Medical DiagnosesSource quoteL75: Kim et al. (DenseNet)\cite{xprotonet} │ 0.780 │ 0.887 │ 0.835 │ 0.710 │ 0.831 │ 0.804 │ 0.734 │ 0.871 │ 0.747 │ 0.840 │ 0.941 │ 0.815 │ 0.799 │ 0.909 │ 0.822 |
| 2024 | ProtoPNet baseline | Mean AUC | 0.809 | Multi-label thoracic disease classification; directly compared with CIPL on NIH ChestX-… | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteL543: Compared with the seminal work of ProtoPNet baseline~\cite{chen2019looks}, our CIPL exhibits a large average AUC improvement from 0.809 to 0.828. |
| 2023 | FedLSM proposed | AUC | 0.791 | federated-learning · runs=3 · clients=8 · classes-per-client=3 | Scale Federated Learning for Label Set Mismatch in Medical Image ClassificationSource quoteL143: Ours │ 0.791 │ 0.960 │ 0.846 │ 0.713 │ 0.763 │ 0.699 |
| 2023 | proposed causal approach proposed | Mean AUC | 0.857 | split: test · backbone=ResNet101 | Chest X-ray Image Classification: A Causal PerspectiveSource quoteL151: Mean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2023 | M-FLAG proposed | AUC | 62.2% | fine-tuned · labeled-data=1% | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteL112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
| 2023 | Proposed instrumental variable learning framework proposed | Mean AUC | 0.867 | Average across 14 thoracic diseases; no split condition is specified in the cited result. | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteL183: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.867 |
| 2023 | DGFN proposed | Mean AUC | 0.850 | split: test | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteL291: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 2023 | MaCo proposed | AUC | 77.3% | 0-shot | Enhancing representation in radiography-reports foundation model: a granular alignment algorithm using masked contrastive learningSource quoteL326: MaCo (Ours) │ 77.3 │ 88.6 │ 90.4 |
| 2023 | DGFN baseline | Mean AUC | 0.850 | Average across 14 thoracic diseases; comparison reported in the same table as the propo… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteL183: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.867 |
| 2023 | MedKLIP baseline | AUC | 76.8% | 0-shot | Enhancing representation in radiography-reports foundation model: a granular alignment algorithm using masked contrastive learningSource quoteL325: MedKLIP │ 76.8 │ 86.9 │ 89.2 |
| 2022 | RGT (Radiomics-Guided Transformer) proposed | Mean AUC | 0.839 | runs=3 | Radiomics-Guided Global-Local transformer for weakly supervised pathology localization in chest X-RaysSource quoteL197: RGT (ours) │ 0.80 │ 0.92 │ 0.78 │ 0.86 │ 0.88 │ 0.88 │ 0.79 │ 0.81 │ 0.839 |
| 2022 | MAE-pretrained ViT-S/16 proposed | mAUC (mean AUC over 14 diseases) | 82.3% | split: test · fine-tuned · params=0.3M · backbone=ViT-S/16 · pretraining-data=0.3M X-rays | Delving into Masked Autoencoders for Multi-Label Thorax Disease ClassificationSource quoteL370: MAE │ ViT-S/16 │ 82.3 |
| 2022 | Clinical-BERT (Ours; proposed pre-trained model) proposed | Mean AUC | 0.8450 | split: test | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quoteL544: 0.8450 |
| 2022 | GTDA error estimation | AUC | 0.75 | split: test | Topological structure of complex predictionsSource quoteL550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
| 2022 | Self confidence | AUC | 0.60 | split: test | Topological structure of complex predictionsSource quoteL550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
| 2022 | Rajpurkar et al. (CheXNet) baseline | Mean AUC | 0.828 | Mean across eight disease classes; reported as the prior state-of-the-art classificatio… | Radiomics-Guided Global-Local transformer for weakly supervised pathology localization in chest X-RaysSource quoteL189: Rajpurkar et al. \cite{rajpurkar2017chexnet} │ 0.82 │ 0.91 │ 0.88 │ 0.72 │ 0.86 │ 0.78 │ 0.76 │ 0.89 │ 0.828 |
| 2022 | DME baseline | Mean AUC | 0.8349 | split: test | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quoteL543: 0.8349 |
| 2021 | XProtoNet (ResNet-50) proposed | Mean AUC | 0.820 | split: test · backbone=ResNet-50 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792. |
| 2021 | XProtoNet (DenseNet-121) proposed | Mean AUC | 0.822 | split: test · backbone=DenseNet-121 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 2021 | XProtoNet (no additional supervision) proposed | Mean AUC | 0.85 | split: val · validation=five-fold cross-validation · supervision=no bounding-box supervision | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL280: XProtoNet (Ours) │ 0.83 │ 0.91 │ 0.89 │ 0.72 │ 0.87 │ 0.82 │ 0.76 │ 0.90 │ 0.80 │ 0.90 │ 0.94 │ 0.82 │ 0.82 │ 0.92 │ 0.85 |
| 2021 | CheXNet (Rajpurkar et al.) baseline | Mean AUC across 8 chest diseases | 0.828 | split: test | Knowledge-Augmented Contrastive Learning for Abnormality Classification and Localization in Chest X-rays with Radiomics using a Feedback LoopSource quoteL136: Rajpurkar et. al.\cite{rajpurkar2017chexnet} │ 0.82 │ 0.91 │ 0.88 │ 0.72 │ 0.86 │ 0.78 │ 0.76 │ 0.89 │ 0.828 |
| 2021 | Highest-performing Patch r×r baseline (ResNet-50) baseline | Mean AUC | 0.792 | split: test · variant=Patch r×r · backbone=ResNet-50 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792. |
| 2021 | Guan et al. (single DenseNet-121) baseline | Mean AUC | 0.816 | split: test · backbone=DenseNet-121 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 2021 | Liu et al. (bounding-box supervision) baseline | Mean AUC | 0.83 | split: val · validation=five-fold cross-validation · supervision=bounding-box supervision | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL279: Liu \etal.~\cite{liu2019align} │ \checkmark │ 0.79 │ 0.87 │ 0.88 │ 0.69 │ 0.81 │ 0.73 │ 0.75 │ 0.89 │ 0.79 │ 0.91 │ 0.93 │ 0.80 │ 0.80 │ 0.92 │ 0.83 |
| 2020 | Wang et al. baseline | Mean AUC across pathology classes | 0.75 | split: test · backbone=ResNet-50 | Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest RadiographsSource quoteL212: Wang~et al. │ 0.70 │ 0.81 │ 0.70 │ 0.81 │ 0.76 │ 0.83 │ 0.79 │ 0.87 │ 0.66 │ 0.69 │ 0.67 │ 0.68 │ 0.66 │ 0.80 │ 0.75 |
| 2020 | Liu et al.* baseline | Mean AUC across pathology classes | 0.83 | split: test · backbone=ResNet-50 · additional-supervision=bounding-box | Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest RadiographsSource quoteL214: Liu~et al. * │ 0.79 │ 0.87 │ 0.79 │ 0.91 │ 0.88 │ 0.93 │ 0.80 │ 0.92 │ 0.69 │ 0.81 │ 0.73 │ 0.80 │ 0.75 │ 0.89 │ 0.83 |
| 2019 | proposed generative adversarial one-class model (U+D+E) proposed non-standard slice | AUC | 0.841 | split: test · runs=5 · training-data=normal CXRs only | Abnormal Chest X-ray Identification With Generative Adversarial One-Class ClassifierSource quoteL111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage. |
| 2019 | proposed generative adversarial one-class model (U+D+E) proposed non-standard slice | AUC | 0.802 | runs=5 · subset=lung opacities · training-data=normal CXRs only | Abnormal Chest X-ray Identification With Generative Adversarial One-Class ClassifierSource quoteL111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage. |
| 2018 | Proposed model with a 1×1 capsule convolutional layer proposed | Average AUC | 0.775 | split: test | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteL102: Average │ 0.738 │ 0.761 │ 0.775 │ 0.626 |