NIH ChestX-ray14
41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API
Also indexed as: nih-chestx-ray14
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | proposed causal approach SOTA frontier | 0.857 | 2023-05-01 | backbone=ResNet101 · Official data split; AUC evaluated on the whole test set. ResNet101 backbone. | Chest X-ray Image Classification: A Causal PerspectiveSource quoteMean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2 | DGFN SOTA frontier | 0.85 | 2023-01-01 | Official split; test-set performance averaged over 14 thoracic diseases, as shown in … | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 3 | Clinical-BERT (Ours; proposed pre-trained model) SOTA frontier | 0.845 | 2022-01-01 | NIH ChestX-ray14 official split; radiograph diagnosis evaluated by AUC for pathology,… | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quote0.8450 |
| 4 | CIPL | 0.828 | 2025-01-01 | Multi-label thoracic disease classification; results on the official dataset split, w… | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteAs can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 5 | XProtoNet (DenseNet-121) SOTA frontier (+1 variant) | 0.822 | 2021-01-01 | backbone=DenseNet-121 · Official-split comparison with Guan et al.; single DenseNet-121 comparator. | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteCompared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 6 | Proposed model with a 1×1 capsule convolutional layer SOTA frontier | 0.775 | 2018-08-01 | Official training/test split; trained on the chest X-ray dataset without additional t… | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteAverage │ 0.738 │ 0.761 │ 0.775 │ 0.626 |
| 7 | GTDA error estimation (+1 variant) | 0.75 | 2023-01-01 | Finding incorrect normal-vs-abnormal test labels among 810 images with expert labels;… | Topological structure of complex predictionsSource quoteFor simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
Showing 17 of 17 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2024 | CIPL proposed | Mean AUC | 0.828 | split: test | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteL541: As can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 2023 | proposed causal approach proposed | Mean AUC | 0.857 | split: test · backbone=ResNet101 | Chest X-ray Image Classification: A Causal PerspectiveSource quoteL151: Mean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2023 | DGFN proposed | Mean AUC | 0.850 | split: test | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteL291: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 2022 | MAE-pretrained ViT-S/16 proposed | mAUC (mean AUC over 14 diseases) | 82.3% | split: test · fine-tuned · params=0.3M · backbone=ViT-S/16 · pretraining-data=0.3M X-rays | Delving into Masked Autoencoders for Multi-Label Thorax Disease ClassificationSource quoteL370: MAE │ ViT-S/16 │ 82.3 |
| 2022 | Clinical-BERT (Ours; proposed pre-trained model) proposed | Mean AUC | 0.8450 | split: test | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quoteL544: 0.8450 |
| 2022 | GTDA error estimation | AUC | 0.75 | split: test | Topological structure of complex predictionsSource quoteL550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
| 2022 | Self confidence | AUC | 0.60 | split: test | Topological structure of complex predictionsSource quoteL550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
| 2022 | DME baseline | Mean AUC | 0.8349 | split: test | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quoteL543: 0.8349 |
| 2021 | XProtoNet (ResNet-50) proposed | Mean AUC | 0.820 | split: test · backbone=ResNet-50 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792. |
| 2021 | XProtoNet (DenseNet-121) proposed | Mean AUC | 0.822 | split: test · backbone=DenseNet-121 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 2021 | CheXNet (Rajpurkar et al.) baseline | Mean AUC across 8 chest diseases | 0.828 | split: test | Knowledge-Augmented Contrastive Learning for Abnormality Classification and Localization in Chest X-rays with Radiomics using a Feedback LoopSource quoteL136: Rajpurkar et. al.\cite{rajpurkar2017chexnet} │ 0.82 │ 0.91 │ 0.88 │ 0.72 │ 0.86 │ 0.78 │ 0.76 │ 0.89 │ 0.828 |
| 2021 | Highest-performing Patch r×r baseline (ResNet-50) baseline | Mean AUC | 0.792 | split: test · variant=Patch r×r · backbone=ResNet-50 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792. |
| 2021 | Guan et al. (single DenseNet-121) baseline | Mean AUC | 0.816 | split: test · backbone=DenseNet-121 | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteL242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 2020 | Wang et al. baseline | Mean AUC across pathology classes | 0.75 | split: test · backbone=ResNet-50 | Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest RadiographsSource quoteL212: Wang~et al. │ 0.70 │ 0.81 │ 0.70 │ 0.81 │ 0.76 │ 0.83 │ 0.79 │ 0.87 │ 0.66 │ 0.69 │ 0.67 │ 0.68 │ 0.66 │ 0.80 │ 0.75 |
| 2020 | Liu et al.* baseline | Mean AUC across pathology classes | 0.83 | split: test · backbone=ResNet-50 · additional-supervision=bounding-box | Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest RadiographsSource quoteL214: Liu~et al. * │ 0.79 │ 0.87 │ 0.79 │ 0.91 │ 0.88 │ 0.93 │ 0.80 │ 0.92 │ 0.69 │ 0.81 │ 0.73 │ 0.80 │ 0.75 │ 0.89 │ 0.83 |
| 2019 | proposed generative adversarial one-class model (U+D+E) proposed non-standard slice | AUC | 0.841 | split: test · runs=5 · training-data=normal CXRs only | Abnormal Chest X-ray Identification With Generative Adversarial One-Class ClassifierSource quoteL111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage. |
| 2018 | Proposed model with a 1×1 capsule convolutional layer proposed | Average AUC | 0.775 | split: test | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteL102: Average │ 0.738 │ 0.761 │ 0.775 │ 0.626 |