0.70.80.80.9201920222025Proposed model with a 1×1 capsule convolutional layer: 0.775 (2018)XProtoNet (ResNet-50): 0.82 (2021)XProtoNet (DenseNet-121): 0.822 (2021)Clinical-BERT (Ours; proposed pre-trained model): 0.845 (2022)Self confidence: 0.6 (2023)GTDA error estimation: 0.75 (2023)DGFN: 0.85 (2023)proposed causal approach: 0.857 (2023)CIPL: 0.828 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 17 of 17 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024CIPL proposedMean AUC0.828split: testCross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and Interpretation
Source quote
L541: As can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885,
2023proposed causal approach proposedMean AUC0.857split: test · backbone=ResNet101Chest X-ray Image Classification: A Causal Perspective
Source quote
L151: Mean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864)
2023DGFN proposedMean AUC0.850split: testDeep reinforcement learning framework for thoracic diseases classification via prior knowledge guidance
Source quote
L291: Mean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873)
2022MAE-pretrained ViT-S/16 proposedmAUC (mean AUC over 14 diseases)82.3%split: test · fine-tuned · params=0.3M · backbone=ViT-S/16 · pretraining-data=0.3M X-raysDelving into Masked Autoencoders for Multi-Label Thorax Disease Classification
Source quote
L370: MAE │ ViT-S/16 │ 82.3
2022Clinical-BERT (Ours; proposed pre-trained model) proposedMean AUC0.8450split: testClinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports Generation
Source quote
L544: 0.8450
2022GTDA error estimationAUC0.75split: testTopological structure of complex predictions
Source quote
L550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60.
2022Self confidenceAUC0.60split: testTopological structure of complex predictions
Source quote
L550: For simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60.
2022DME baselineMean AUC0.8349split: testClinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports Generation
Source quote
L543: 0.8349
2021XProtoNet (ResNet-50) proposedMean AUC0.820split: test · backbone=ResNet-50XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792.
2021XProtoNet (DenseNet-121) proposedMean AUC0.822split: test · backbone=DenseNet-121XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822.
2021CheXNet (Rajpurkar et al.) baselineMean AUC across 8 chest diseases0.828split: testKnowledge-Augmented Contrastive Learning for Abnormality Classification and Localization in Chest X-rays with Radiomics using a Feedback Loop
Source quote
L136: Rajpurkar et. al.\cite{rajpurkar2017chexnet} │ 0.82 │ 0.91 │ 0.88 │ 0.72 │ 0.86 │ 0.78 │ 0.76 │ 0.89 │ 0.828
2021Highest-performing Patch r×r baseline (ResNet-50) baselineMean AUC0.792split: test · variant=Patch r×r · backbone=ResNet-50XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L217: By contrast, because XProtoNet predicts the adaptive area to compare, it achieves higher performance in all classes than the baselines: the mean AUC score of 0.820 is 3.5% higher than the highest baseline \text{Patch}-r× r mean AUC score, which is 0.792.
2021Guan et al. (single DenseNet-121) baselineMean AUC0.816split: test · backbone=DenseNet-121XProtoNet: Diagnosis in Chest Radiography With Global and Local Explanations
Source quote
L242: Compared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822.
2020Wang et al. baselineMean AUC across pathology classes0.75split: test · backbone=ResNet-50Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L212: Wang~et al. │ 0.70 │ 0.81 │ 0.70 │ 0.81 │ 0.76 │ 0.83 │ 0.79 │ 0.87 │ 0.66 │ 0.69 │ 0.67 │ 0.68 │ 0.66 │ 0.80 │ 0.75
2020Liu et al.* baselineMean AUC across pathology classes0.83split: test · backbone=ResNet-50 · additional-supervision=bounding-boxSelf-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L214: Liu~et al. * │ 0.79 │ 0.87 │ 0.79 │ 0.91 │ 0.88 │ 0.93 │ 0.80 │ 0.92 │ 0.69 │ 0.81 │ 0.73 │ 0.80 │ 0.75 │ 0.89 │ 0.83
2019proposed generative adversarial one-class model (U+D+E) proposed non-standard sliceAUC0.841split: test · runs=5 · training-data=normal CXRs onlyAbnormal Chest X-ray Identification With Generative Adversarial One-Class Classifier
Source quote
L111: We first quantitatively evaluate the classification performance using the area under the receiver operating characteristic (AUC) score. We conduct ablation studies to the proposed framework. The baseline method is the U-Net autoencoder U truncated from the proposed model. Then we add a second encoder E and decoder D to U respectively, to compare their performance with the whole network (U+D+E). The training and evaluation process is repeated five times to reduce randomness. The normal and abnormal (or lung opacities) CXR classification results in terms of AUCs are shown in Table \ref{tab:results}. The proposed model achieves an average AUC of 0.841 on the testing set for normal and abnormal CXRs with 14 major findings, and an average AUC of 0.802 for normal versus abnormal CXRs with lung opacities, which largely outperforms the baseline U-Net model without adversarial learning. Each of the proposed modules contributes to the final model improvement. The overall result is encouraging given the fact that the dataset contains difficult cases (e.g., mild abnormalities) and only normal CXRs are used in the training stage.
2018Proposed model with a 1×1 capsule convolutional layer proposedAverage AUC0.775split: testDynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area Localization
Source quote
L102: Average │ 0.738 │ 0.761 │ 0.775 │ 0.626