NIH ChestX-ray14
41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API
Also indexed as: nih-chestx-ray14
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | proposed causal approach SOTA frontier | 0.857 | 2023-05-01 | backbone=ResNet101 · Official data split; AUC evaluated on the whole test set. ResNet101 backbone. | Chest X-ray Image Classification: A Causal PerspectiveSource quoteMean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2 | DGFN SOTA frontier | 0.85 | 2023-01-01 | Official split; test-set performance averaged over 14 thoracic diseases, as shown in … | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 3 | Clinical-BERT (Ours; proposed pre-trained model) SOTA frontier | 0.845 | 2022-01-01 | NIH ChestX-ray14 official split; radiograph diagnosis evaluated by AUC for pathology,… | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quote0.8450 |
| 4 | CIPL | 0.828 | 2025-01-01 | Multi-label thoracic disease classification; results on the official dataset split, w… | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteAs can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 5 | XProtoNet (DenseNet-121) SOTA frontier (+1 variant) | 0.822 | 2021-01-01 | backbone=DenseNet-121 · Official-split comparison with Guan et al.; single DenseNet-121 comparator. | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteCompared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 6 | Proposed model with a 1×1 capsule convolutional layer SOTA frontier | 0.775 | 2018-08-01 | Official training/test split; trained on the chest X-ray dataset without additional t… | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteAverage │ 0.738 │ 0.761 │ 0.775 │ 0.626 |
| 7 | GTDA error estimation (+1 variant) | 0.75 | 2023-01-01 | Finding incorrect normal-vs-abnormal test labels among 810 images with expert labels;… | Topological structure of complex predictionsSource quoteFor simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | VIVID-Med proposed | macro-AUC | 0.7225 | 0-shot | VIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTsSource quoteL4: Vision-language pretraining has driven significant progress in medical image analysis. However, current methods typically supervise visual encoders using one-hot labels or free-form text, neither of which effectively captures the complex semantic relationships among clinical findings. In this study, we introduce VIVID-Med, a novel framework that leverages a frozen large language model (LLM) as a structured semantic teacher to pretrain medical vision transformers (ViTs). VIVID-Med translates clinical findings into verifiable JSON field-state pairs via a Unified Medical Schema (UMS), utilizing answerability-aware masking to focus optimization. It then employs Structured Prediction Decomposition (SPD) to partition cross-attention into orthogonality-regularized query groups, extracting complementary visual aspects. Crucially, the LLM is discarded post-training, yielding a lightweight, deployable ViT-only backbone. We evaluated VIVID-Med across multiple settings: on CheXpert linear probing, it achieves a macro-AUC of 0.8588, outperforming BiomedCLIP by {+}6.65 points while using 500× less data. It also demonstrates robust zero-shot cross-domain transfer to NIH ChestX-ray14 (0.7225 macro-AUC) and strong cross-modality generalization to CT, achieving 0.8413 AUC on LIDC-IDRI lung nodule classification and 0.9969 macro-AUC on OrganAMNIST 11-organ classification. VIVID-Med offers a highly efficient, scalable alternative to deploying resource-heavy vision-language models in clinical settings. |
| 2023 | MaCo proposed | AUC | 77.3% | 0-shot | Enhancing representation in radiography-reports foundation model: a granular alignment algorithm using masked contrastive learningSource quoteL326: MaCo (Ours) │ 77.3 │ 88.6 │ 90.4 |
| 2023 | MedKLIP baseline | AUC | 76.8% | 0-shot | Enhancing representation in radiography-reports foundation model: a granular alignment algorithm using masked contrastive learningSource quoteL325: MedKLIP │ 76.8 │ 86.9 │ 89.2 |