NIH ChestX-ray14
41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API
Also indexed as: nih-chestx-ray14
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | proposed causal approach SOTA frontier | 0.857 | 2023-05-01 | backbone=ResNet101 · Official data split; AUC evaluated on the whole test set. ResNet101 backbone. | Chest X-ray Image Classification: A Causal PerspectiveSource quoteMean AUC │ 0.807 │ 0.819 │ 0.832 │ 0.850 │ 0.857 (0.849, 0.864) |
| 2 | DGFN SOTA frontier | 0.85 | 2023-01-01 | Official split; test-set performance averaged over 14 thoracic diseases, as shown in … | Deep reinforcement learning framework for thoracic diseases classification via prior knowledge guidanceSource quoteMean AUC │ 0.745 │ 0.819 │ 0.832 │ 0.850 │ 0.866 (0.859, 0.873) |
| 3 | Clinical-BERT (Ours; proposed pre-trained model) SOTA frontier | 0.845 | 2022-01-01 | NIH ChestX-ray14 official split; radiograph diagnosis evaluated by AUC for pathology,… | Clinical-BERT: Vision-Language Pre-training for Radiograph Diagnosis and Reports GenerationSource quote0.8450 |
| 4 | CIPL | 0.828 | 2025-01-01 | Multi-label thoracic disease classification; results on the official dataset split, w… | Cross- and Intra-Image Prototypical Learning for Multi-Label Disease Diagnosis and InterpretationSource quoteAs can be observed, our CIPL method achieves the best classification results among all these approaches with a mean AUC of 0.828, a mean F1 score of 0.383, and a mean accuracy of 0.885, |
| 5 | XProtoNet (DenseNet-121) SOTA frontier (+1 variant) | 0.822 | 2021-01-01 | backbone=DenseNet-121 · Official-split comparison with Guan et al.; single DenseNet-121 comparator. | XProtoNet: Diagnosis in Chest Radiography With Global and Local ExplanationsSource quoteCompared with Guan~\etal~\cite{guan2020multi}, who use a single \mbox{DenseNet-121}, the mean AUC score is improved from 0.816 to 0.822. |
| 6 | Proposed model with a 1×1 capsule convolutional layer SOTA frontier | 0.775 | 2018-08-01 | Official training/test split; trained on the chest X-ray dataset without additional t… | Dynamic Routing on Deep Neural Network for Thoracic Disease Classification and Sensitive Area LocalizationSource quoteAverage │ 0.738 │ 0.761 │ 0.775 │ 0.626 |
| 7 | GTDA error estimation (+1 variant) | 0.75 | 2023-01-01 | Finding incorrect normal-vs-abnormal test labels among 810 images with expert labels;… | Topological structure of complex predictionsSource quoteFor simplicity, images in the test set where such differences are larger than 0.5 are considered to have incorrect labels. A demonstration on this process can be found in \Cref{chest_xray_demo}. Overall, out of the 810 testing images with expert labels, GTDA highlights 265 images are likely to have incorrect normal vs abnormal labels and 138 of them are confirmed by the expert labels, which gives a precision of 0.52 and a recall of 0.62. As a comparison, randomly sampling 265 images for experts to check can only find around 73 images with incorrect labels in average. More detailed results on each component are shown in \Cref{tab:chest}. By testing multiple thresholds instead of 0.5, we get an AUC score of 0.75. As a comparison, using self confidence~\cite{northcutt2021confidentlearning} gives an overall AUC score of 0.60. |
Showing 10 of 10 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | AT-CXR (LLM Router) proposed non-standard slice | Accuracy | 95.3% | subset=balanced · coverage=100% · evaluation=five-fold | AT-CXR: Uncertainty-Aware Agentic Triage for Chest X-raysSource quoteL17: To address these gaps, we propose AT-CXR (Agentic Triage for Chest X-ray), an uncertainty-aware agentic framework designed to make autonomous, safe triage decisions under clinical resource and reliability constraints. AT-CXR treats triage as a stepwise policy over a fixed action set: given an initial assessment score and a distribution-fit signal, the router may invoke test-time augmentation to probe stability, consult a committee of experts, or escalate to a vision–language model. The policy can iterate and then either issue an automated label or abstain with a suggested label for human review. A folder watcher and auto-sorting complete an end-to-end pipeline, reducing cognitive load and aligning with clinical throughput. For interpretability, AT-CXR generates Class Activation Maps~\cite{zhou2016learning} that highlight suspicious regions alongside the triage outcome. We instantiate two router designs over the same inputs and action set: a deterministic rule-based router and an LLM-decided router. Evaluated on NIH ChestX-ray14~\cite{wang2017chestx} for pulmonary-edema triage, the LLM and rule-based routers achieve overall accuracies of 95.3% and 93.8%, respectively, at 100% coverage (including abstained-with-suggestion outputs). Both designs surpass strong zero-shot vision–language models and state-of-the-art supervised classifiers, achieving higher full-coverage accuracy and stronger selective-prediction performance, as reflected in lower AURC and reduced error at high coverage, while maintaining low latency and modest computational requirements that are compatible with clinical workflows. These results highlight the potential of uncertainty-aware agentic policies to enable safe and efficient CXR triage. |
| 2025 | AT-CXR (Rule-Based Router) proposed non-standard slice | Accuracy | 93.8% | subset=balanced · coverage=100% · evaluation=five-fold | AT-CXR: Uncertainty-Aware Agentic Triage for Chest X-raysSource quoteL17: To address these gaps, we propose AT-CXR (Agentic Triage for Chest X-ray), an uncertainty-aware agentic framework designed to make autonomous, safe triage decisions under clinical resource and reliability constraints. AT-CXR treats triage as a stepwise policy over a fixed action set: given an initial assessment score and a distribution-fit signal, the router may invoke test-time augmentation to probe stability, consult a committee of experts, or escalate to a vision–language model. The policy can iterate and then either issue an automated label or abstain with a suggested label for human review. A folder watcher and auto-sorting complete an end-to-end pipeline, reducing cognitive load and aligning with clinical throughput. For interpretability, AT-CXR generates Class Activation Maps~\cite{zhou2016learning} that highlight suspicious regions alongside the triage outcome. We instantiate two router designs over the same inputs and action set: a deterministic rule-based router and an LLM-decided router. Evaluated on NIH ChestX-ray14~\cite{wang2017chestx} for pulmonary-edema triage, the LLM and rule-based routers achieve overall accuracies of 95.3% and 93.8%, respectively, at 100% coverage (including abstained-with-suggestion outputs). Both designs surpass strong zero-shot vision–language models and state-of-the-art supervised classifiers, achieving higher full-coverage accuracy and stronger selective-prediction performance, as reflected in lower AURC and reduced error at high coverage, while maintaining low latency and modest computational requirements that are compatible with clinical workflows. These results highlight the potential of uncertainty-aware agentic policies to enable safe and efficient CXR triage. |
| 2022 | NIH DenseNet121 model proposed | k-robust accuracy (k=1) | 13.78% | k=1 · model=DenseNet121 · attack=untargeted | On Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best PracticesSource quoteL279: \multirow{5}{*}{k=1} │ NIH │ 13.78 │ 1.38 │ 9.66 │ 8.47 │ 7.12 │ 2.25 |
| 2022 | NIH DenseNet121 model proposed | k-robust accuracy (k=1) | 2.69% | k=1 · loss=BCE · model=DenseNet121 · attack=targeted | On Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best PracticesSource quoteL433: \multirow{7}{*}{BCE} │ k=1 \uparrow │ 2.69 │ 1.19 │ 0.19 │ 0.69 │ 0 │ 3 |
| 2022 | AllD DenseNet121 model proposed | k-robust accuracy (k=3) | 32.12% | k=3 · model=DenseNet121 · attack=untargeted · training-dataset=AllD | On Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best PracticesSource quoteL291: AllD │ 21.69 │ 6.34 │ 35.38 │ 27.12 │ 27.34 │ 32.12 |
| 2022 | AllD DenseNet121 model proposed | k-robust accuracy (k=3) | 11.12% | k=3 · loss=BCE · model=DenseNet121 · attack=targeted · training-dataset=AllD | On Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best PracticesSource quoteL434: k=3 \uparrow │ 12.43 │ 8.19 │ 16.5 │ 1.75 │ 0 │ 11.12 |
| 2020 | CIAN-CEN proposed | Mean disease localization accuracy | 0.67 | split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1 | Contralaterally Enhanced Networks for Thoracic Disease DetectionSource quoteL225: CIAN-CEN │ 0.71 │ 0.91 │ 0.74 │ 0.85 │ 0.79 │ 0.47 │ 0.40 │ 0.50 │ 0.67 |
| 2020 | SGL proposed | Mean disease localization accuracy | 0.66 | IoU-threshold=0.1 · classification-threshold=0.5 | Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest RadiographsSource quoteL232: SGL (Ours) │ 0.67 │ 0.94 │ 0.67 │ 0.81 │ 0.71 │ 0.41 │ 0.66 │ 0.43 │ 0.66 |
| 2020 | CIAN baseline | Mean disease localization accuracy | 0.62 | split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1 | Contralaterally Enhanced Networks for Thoracic Disease DetectionSource quoteL224: CIAN~\cite{liu2019align} │ 0.67 │ 0.86 │ 0.71 │ 0.83 │ 0.77 │ 0.45 │ 0.29 │ 0.40 │ 0.62 |
| 2020 | Wang et al. baseline | Mean disease localization accuracy | 0.57 | IoU-threshold=0.1 · classification-threshold=0.5 | Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest RadiographsSource quoteL229: \multirow{4}{*}{0.1} │ Wang~et al. \cite{wang2017chestx} │ 0.69 │ 0.94 │ 0.66 │ 0.71 │ 0.40 │ 0.14 │ 0.63 │ 0.38 │ 0.57 |