NIH ChestX-ray14

41 papers · 102 extracted observations · image classification · vision · Markdown · CSV · JSON API

Also indexed as: nih-chestx-ray14

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

0.70.80.80.9201920222025Proposed model with a 1×1 capsule convolutional layer: 0.775 (2018)XProtoNet (ResNet-50): 0.82 (2021)XProtoNet (DenseNet-121): 0.822 (2021)Clinical-BERT (Ours; proposed pre-trained model): 0.845 (2022)Self confidence: 0.6 (2023)GTDA error estimation: 0.75 (2023)DGFN: 0.85 (2023)proposed causal approach: 0.857 (2023)CIPL: 0.828 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025AT-CXR (LLM Router) proposed non-standard sliceAccuracy95.3%subset=balanced · coverage=100% · evaluation=five-foldAT-CXR: Uncertainty-Aware Agentic Triage for Chest X-rays
Source quote
L17: To address these gaps, we propose AT-CXR (Agentic Triage for Chest X-ray), an uncertainty-aware agentic framework designed to make autonomous, safe triage decisions under clinical resource and reliability constraints. AT-CXR treats triage as a stepwise policy over a fixed action set: given an initial assessment score and a distribution-fit signal, the router may invoke test-time augmentation to probe stability, consult a committee of experts, or escalate to a vision–language model. The policy can iterate and then either issue an automated label or abstain with a suggested label for human review. A folder watcher and auto-sorting complete an end-to-end pipeline, reducing cognitive load and aligning with clinical throughput. For interpretability, AT-CXR generates Class Activation Maps~\cite{zhou2016learning} that highlight suspicious regions alongside the triage outcome. We instantiate two router designs over the same inputs and action set: a deterministic rule-based router and an LLM-decided router. Evaluated on NIH ChestX-ray14~\cite{wang2017chestx} for pulmonary-edema triage, the LLM and rule-based routers achieve overall accuracies of 95.3% and 93.8%, respectively, at 100% coverage (including abstained-with-suggestion outputs). Both designs surpass strong zero-shot vision–language models and state-of-the-art supervised classifiers, achieving higher full-coverage accuracy and stronger selective-prediction performance, as reflected in lower AURC and reduced error at high coverage, while maintaining low latency and modest computational requirements that are compatible with clinical workflows. These results highlight the potential of uncertainty-aware agentic policies to enable safe and efficient CXR triage.
2025AT-CXR (Rule-Based Router) proposed non-standard sliceAccuracy93.8%subset=balanced · coverage=100% · evaluation=five-foldAT-CXR: Uncertainty-Aware Agentic Triage for Chest X-rays
Source quote
L17: To address these gaps, we propose AT-CXR (Agentic Triage for Chest X-ray), an uncertainty-aware agentic framework designed to make autonomous, safe triage decisions under clinical resource and reliability constraints. AT-CXR treats triage as a stepwise policy over a fixed action set: given an initial assessment score and a distribution-fit signal, the router may invoke test-time augmentation to probe stability, consult a committee of experts, or escalate to a vision–language model. The policy can iterate and then either issue an automated label or abstain with a suggested label for human review. A folder watcher and auto-sorting complete an end-to-end pipeline, reducing cognitive load and aligning with clinical throughput. For interpretability, AT-CXR generates Class Activation Maps~\cite{zhou2016learning} that highlight suspicious regions alongside the triage outcome. We instantiate two router designs over the same inputs and action set: a deterministic rule-based router and an LLM-decided router. Evaluated on NIH ChestX-ray14~\cite{wang2017chestx} for pulmonary-edema triage, the LLM and rule-based routers achieve overall accuracies of 95.3% and 93.8%, respectively, at 100% coverage (including abstained-with-suggestion outputs). Both designs surpass strong zero-shot vision–language models and state-of-the-art supervised classifiers, achieving higher full-coverage accuracy and stronger selective-prediction performance, as reflected in lower AURC and reduced error at high coverage, while maintaining low latency and modest computational requirements that are compatible with clinical workflows. These results highlight the potential of uncertainty-aware agentic policies to enable safe and efficient CXR triage.
2022NIH DenseNet121 model proposedk-robust accuracy (k=1)13.78%k=1 · model=DenseNet121 · attack=untargetedOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L279: \multirow{5}{*}{k=1} │ NIH │ 13.78 │ 1.38 │ 9.66 │ 8.47 │ 7.12 │ 2.25
2022NIH DenseNet121 model proposedk-robust accuracy (k=1)2.69%k=1 · loss=BCE · model=DenseNet121 · attack=targetedOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L433: \multirow{7}{*}{BCE} │ k=1 \uparrow │ 2.69 │ 1.19 │ 0.19 │ 0.69 │ 0 │ 3
2022AllD DenseNet121 model proposedk-robust accuracy (k=3)32.12%k=3 · model=DenseNet121 · attack=untargeted · training-dataset=AllDOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L291: AllD │ 21.69 │ 6.34 │ 35.38 │ 27.12 │ 27.34 │ 32.12
2022AllD DenseNet121 model proposedk-robust accuracy (k=3)11.12%k=3 · loss=BCE · model=DenseNet121 · attack=targeted · training-dataset=AllDOn Evaluating Adversarial Robustness of Chest X-ray Classification: Pitfalls and Best Practices
Source quote
L434: k=3 \uparrow │ 12.43 │ 8.19 │ 16.5 │ 1.75 │ 0 │ 11.12
2020CIAN-CEN proposedMean disease localization accuracy0.67split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1Contralaterally Enhanced Networks for Thoracic Disease Detection
Source quote
L225: CIAN-CEN │ 0.71 │ 0.91 │ 0.74 │ 0.85 │ 0.79 │ 0.47 │ 0.40 │ 0.50 │ 0.67
2020SGL proposedMean disease localization accuracy0.66IoU-threshold=0.1 · classification-threshold=0.5Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L232: SGL (Ours) │ 0.67 │ 0.94 │ 0.67 │ 0.81 │ 0.71 │ 0.41 │ 0.66 │ 0.43 │ 0.66
2020CIAN baselineMean disease localization accuracy0.62split: test · weakly-supervised · test-subset=880 images with bounding-box annotations · IoU-threshold=0.1Contralaterally Enhanced Networks for Thoracic Disease Detection
Source quote
L224: CIAN~\cite{liu2019align} │ 0.67 │ 0.86 │ 0.71 │ 0.83 │ 0.77 │ 0.45 │ 0.29 │ 0.40 │ 0.62
2020Wang et al. baselineMean disease localization accuracy0.57IoU-threshold=0.1 · classification-threshold=0.5Self-guided Multiple Instance Learning for Weakly Supervised Disease Classification and Localization in Chest Radiographs
Source quote
L229: \multirow{4}{*}{0.1} │ Wang~et al. \cite{wang2017chestx} │ 0.69 │ 0.94 │ 0.66 │ 0.71 │ 0.40 │ 0.14 │ 0.63 │ 0.38 │ 0.57