MS MARCO · Question Answering

350 papers · 980 extracted observations · information retrieval · language · Markdown · CSV · JSON API

Also indexed as: MSMARCO, ms-marco

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Question Answering: proposed/measured results on test (including papers where test split is standard/implicit).

0.20.50.81.0202420252026Gemma-1.1-2B (RAG-CT): 0.277 (2025)EmoRAG (Contriever): 0.98 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 13 of 13 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Gemma-1.1-2B (RAG-CT) proposedBERT-F10.277Question Answering · split: test · params=2B · model=Gemma-1.1-2B · prompt=RAG-CTRAP: A Metric for Balancing Repetition and Performance in Open-Source Large Language Models
Source quote
L306: 0.277
2025ScaNN baselineQ&A accuracy (correctness rate)74.9%Question Answering · split: test · rag · k=10 · Recall@10=0.90 · generator=Gemini-2.0-FlashTowards Robustness: A Critique of Current Vector Database Assessments
Source quote
L1218: While Q\ │ A accuracy increases with average recall within each index, Figure~\ref{fig:qa-accuracy}(a) reveals a clear divergence across indexes: configurations of ScaNN\xspace consistently achieve higher Q\ │ A accuracy than those of DiskANN\xspace at similar average recall levels. Notably, a ScaNN\xspace configuration with \recallat{10} = 0.90 has the same Q\ │ A accuracy as a DiskANN\xspace configuration with \recallat{10} = 0.96 (74.9%). This ScaNN\xspace configuration also provides significantly higher throughput than the DiskANN\xspace with very high average \recallat{10} (25,054 QPS vs. 14,606 QPS), highlighting its superior efficiency.
2025DiskANN baselineQ&A accuracy (correctness rate)74.9%Question Answering · split: test · rag · k=10 · Recall@10=0.96 · generator=Gemini-2.0-FlashTowards Robustness: A Critique of Current Vector Database Assessments
Source quote
L1218: While Q\ │ A accuracy increases with average recall within each index, Figure~\ref{fig:qa-accuracy}(a) reveals a clear divergence across indexes: configurations of ScaNN\xspace consistently achieve higher Q\ │ A accuracy than those of DiskANN\xspace at similar average recall levels. Notably, a ScaNN\xspace configuration with \recallat{10} = 0.90 has the same Q\ │ A accuracy as a DiskANN\xspace configuration with \recallat{10} = 0.96 (74.9%). This ScaNN\xspace configuration also provides significantly higher throughput than the DiskANN\xspace with very high average \recallat{10} (25,054 QPS vs. 14,606 QPS), highlighting its superior efficiency.
2023Neural + Reader pipeline proposed non-standard slicelabel flipped for the better56.7%Question Answering · split: test · collection=V1Retrieving Supporting Evidence for LLMs Generated Answers
Source quote
L177: For the 60 entries where the predicted label changed when the reader is used, 34 (56.7%) of them the label flipped for the better, 14 (23.3%) of them the original label is correct and should not be flipped, 8 (13.3%) of them both the original label and the new label are wrong, and 4 (6.7%) of them the reader made mistake. In general, the use of the reader does appear to improve classification accuracy.
2023Neural + Reader pipeline proposed non-standard sliceoriginal label is correct and should not be flipped23.3%Question Answering · split: test · collection=V1Retrieving Supporting Evidence for LLMs Generated Answers
Source quote
L177: For the 60 entries where the predicted label changed when the reader is used, 34 (56.7%) of them the label flipped for the better, 14 (23.3%) of them the original label is correct and should not be flipped, 8 (13.3%) of them both the original label and the new label are wrong, and 4 (6.7%) of them the reader made mistake. In general, the use of the reader does appear to improve classification accuracy.
2023Neural + Reader answer vs. generated answer proposedGenerated is Better10%Question Answering · split: test · collection=V1Retrieving Supporting Evidence for LLMs Generated Answers
Source quote
L189: No │ 2 (10%) │ 9 (45%) │ 9 (45%)
2023BM25 vs. neural retrieval stack baselineBM25 passage is poor31.7%Question Answering · split: test · collection=V1Retrieving Supporting Evidence for LLMs Generated Answers
Source quote
L149: \item BM25 passage is poor: 19 (31.7%)
2022BERTimbau proposed non-standard sliceTest Accuracy99.8 %Question Answering · split: test · subset=biomedical · language=PortugueseIntegrating question answering and text-to-SQL in Portuguese
Source quote
L155: 99.8 % │ 98.0% │ 99.6%
2018LSTM1 + pointer softmax baselineBLEU-128Question Answering · split: test · evaluation=generativeFocused Hierarchical RNNs for Conditional Sequence Processing
Source quote
L343: LSTM1 + pointer softmax │ 24.8 │ 26.5 │ 28 │ 28
2017S-Net proposedROUGE-L45.23Question Answering · split: test · variant=synthesis · ensemble=falseS-Net: From Answer Extraction to Answer Synthesis for Machine Reading Comprehension
Source quote
L274: S-Net │ 45.23 │ 43.78
2017S-Net (Extraction, Ensemble) ablationROUGE-L42.92Question Answering · split: test · variant=extraction · ensemble=trueS-Net: From Answer Extraction to Answer Synthesis for Machine Reading Comprehension
Source quote
L273: S-Net (Extraction, Ensemble) │ 42.92 │ 44.97
2017S-Net (Extraction, Ensemble) ablationBLEU-144.97Question Answering · split: test · variant=extraction · ensemble=trueS-Net: From Answer Extraction to Answer Synthesis for Machine Reading Comprehension
Source quote
L273: S-Net (Extraction, Ensemble) │ 42.92 │ 44.97
2017S-Net (Extraction) ablationROUGE-L41.45Question Answering · split: test · variant=extraction · ensemble=falseS-Net: From Answer Extraction to Answer Synthesis for Machine Reading Comprehension
Source quote
L272: S-Net (Extraction) │ 41.45 │ 44.08