MS MARCO

350 papers · 980 extracted observations · information retrieval · language · Markdown · CSV · JSON API

Also indexed as: MSMARCO, ms-marco

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Information Retrieval: proposed/measured results on test (including papers where test split is standard/implicit).

0.20.40.60.8202220242026TM2C2 (BM25 + all-MiniLM-L6-v2; α=0.8): 0.454 (2022)BM25: 0.228 (2023)NAIL: 0.377 (2023)BM25+NAIL: 0.377 (2023)Dual-encoder retrieval trained on DP synthetic data (T5-Base): 0.2027 (2024)EqualizeIR: 0.48 (2025)Tiptoe-style architecture: 0.513 (2025)PIR-RAG: 0.799 (2025)Graph-PIR: 0.901 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026RAGSentinel proposedACC0.78Question Answering · attack=anchor-mimicryRAGSentinel: Certifiable Geometric Consensus for Robust Retrieval-Augmented Generation
Source quote
L2098: 0.78/0.07 │ 0.72/0.11 │ 0.81/0.07
2026RASR proposedToken Acc. ↑99.76%Text Reconstruction · backbone=QwenInverting the Hidden: Unveiling Multimodal Privacy Leakage in Collaborative LVLM Inference
Source quote
L526: 99.76 │ 98.33 │ 99.81
2026RASR proposedToken Acc. ↑99.90%Text Reconstruction · backbone=LLaVAInverting the Hidden: Unveiling Multimodal Privacy Leakage in Collaborative LVLM Inference
Source quote
L527: 99.90 │ 99.17 │ 99.97
2026SIPIT baselineToken Acc. ↑95.98%Text Reconstruction · backbone=QwenInverting the Hidden: Unveiling Multimodal Privacy Leakage in Collaborative LVLM Inference
Source quote
L522: 95.98 │ 84.17 │ 96.97
2026SIPIT baselineToken Acc. ↑99.20%Text Reconstruction · backbone=LLaVAInverting the Hidden: Unveiling Multimodal Privacy Leakage in Collaborative LVLM Inference
Source quote
L523: 99.20 │ 93.33 │ 99.21
2025LLaMA 1B baseline (pre-GSQ) baselineaccuracy81.12%Question Answering · params=1B · backbone=LLaMA 1BLLM Compression: How Far Can We Go in Balancing Size and Performance?
Source quote
L76: The results are summarized and analyzed in Table \ref{tab:quantization-summary}. For the LLaMA 1B model, GSQ actually improved accuracy on MS MARCO (81.12%~\rightarrow~84.04%) with minimal impact on latency, memory, or throughput. GPTQ maintained high accuracy, with a small reduction in memory usage after quantization. On BoolQ, GSQ significantly increased throughput (69.57~\rightarrow~364.91), while accuracy remained mostly unchanged for both. On GSM8K, GSQ showed a slight accuracy drop (1.21%~\rightarrow~1.14%) with a small increase in memory use.
2025ScaNN baselineQ&A accuracy (correctness rate)74.9%Question Answering · split: test · rag · k=10 · Recall@10=0.90 · generator=Gemini-2.0-FlashTowards Robustness: A Critique of Current Vector Database Assessments
Source quote
L1218: While Q\ │ A accuracy increases with average recall within each index, Figure~\ref{fig:qa-accuracy}(a) reveals a clear divergence across indexes: configurations of ScaNN\xspace consistently achieve higher Q\ │ A accuracy than those of DiskANN\xspace at similar average recall levels. Notably, a ScaNN\xspace configuration with \recallat{10} = 0.90 has the same Q\ │ A accuracy as a DiskANN\xspace configuration with \recallat{10} = 0.96 (74.9%). This ScaNN\xspace configuration also provides significantly higher throughput than the DiskANN\xspace with very high average \recallat{10} (25,054 QPS vs. 14,606 QPS), highlighting its superior efficiency.
2025DiskANN baselineQ&A accuracy (correctness rate)74.9%Question Answering · split: test · rag · k=10 · Recall@10=0.96 · generator=Gemini-2.0-FlashTowards Robustness: A Critique of Current Vector Database Assessments
Source quote
L1218: While Q\ │ A accuracy increases with average recall within each index, Figure~\ref{fig:qa-accuracy}(a) reveals a clear divergence across indexes: configurations of ScaNN\xspace consistently achieve higher Q\ │ A accuracy than those of DiskANN\xspace at similar average recall levels. Notably, a ScaNN\xspace configuration with \recallat{10} = 0.90 has the same Q\ │ A accuracy as a DiskANN\xspace configuration with \recallat{10} = 0.96 (74.9%). This ScaNN\xspace configuration also provides significantly higher throughput than the DiskANN\xspace with very high average \recallat{10} (25,054 QPS vs. 14,606 QPS), highlighting its superior efficiency.
2024Gen^2IR proposedAcc. (grounded-answer generation accuracy)0.023Grounded Answer Generation · split: trec-dl-2019 · evaluator=ALBERT-base-vitaminc · generator=GPT-3Genetic Approach to Mitigate Hallucination in Generative IR
Source quote
L169: \multirow{3}{*}{GPT-3} │ Gen^2IR │ 1 │ 40 │ 2 │ 0.023 │ 1 │ 42 │ 0 │ 0.023 │ 8 │ 34 │ 1 │ 0.186 │ 10 │ 33 │ 0 │ 0.233
2024Gen^2IR proposedAcc. (grounded-answer generation accuracy)0.148Grounded Answer Generation · split: trec-dl-2020 · evaluator=ALBERT-base-vitaminc · generator=GPT-3Genetic Approach to Mitigate Hallucination in Generative IR
Source quote
L185: \multirow{3}{*}{DL 20} │ Gen^2IR │ 8 │ 43 │ 3 │ 0.148 │ 6 │ 45 │ 3 │ 0.111 │ 11 │ 33 │ 10 │ 0.204 │ 12 │ 42 │ 0 │ 0.222
2024Gen^2IR proposed non-standard sliceAcc. (grounded-answer generation accuracy)0.110Grounded Answer Generation · split: val · subset=sample · evaluator=ALBERT-base-vitaminc · generator=GPT-3Genetic Approach to Mitigate Hallucination in Generative IR
Source quote
L188: \multirow{3}{*}{\shortstack{Dev\\(sample)}} │ Gen^2IR │ 11 │ 82 │ 7 │ 0.110 │ 11 │ 84 │ 5 │ 0.110 │ 25 │ 65 │ 10 │ 0.250 │ 22 │ 76 │ 2 │ 0.220
2024GAuGE2 (Rouge2) baselineAcc. (grounded-answer generation accuracy)0.861Grounded Answer Generation · split: trec-dl-2019 · evaluator=ALBERT-base-vitaminc · generator=GPT-3Genetic Approach to Mitigate Hallucination in Generative IR
Source quote
L171: GAuGE2 │ 37 │ 6 │ 0 │ 0.861 │ 37 │ 6 │ 0 │ 0.861 │ 41 │ 2 │ 0 │ 0.954 │ 36 │ 7 │ 0 │ 0.837
2024GAuGE2 (Rouge2) baselineAcc. (grounded-answer generation accuracy)0.852Grounded Answer Generation · split: trec-dl-2020 · evaluator=ALBERT-base-vitaminc · generator=GPT-3Genetic Approach to Mitigate Hallucination in Generative IR
Source quote
L187: GAuGE2 │ 46 │ 8 │ 0 │ 0.852 │ 48 │ 6 │ 0 │ 0.889 │ 51 │ 3 │ 0 │ 0.944 │ 50 │ 4 │ 0 │ 0.926
2024GAuGE2 (Rouge2) baseline non-standard sliceAcc. (grounded-answer generation accuracy)0.830Grounded Answer Generation · split: val · subset=sample · evaluator=ALBERT-base-vitaminc · generator=GPT-3Genetic Approach to Mitigate Hallucination in Generative IR
Source quote
L190: GAuGE2 │ 83 │ 17 │ 0 │ 0.830 │ 81 │ 19 │ 0 │ 0.810 │ 91 │ 9 │ 0 │ 0.910 │ 89 │ 11 │ 0 │ 0.890
2023Partitioned inverted-index IVF (Weak Sinnamon; spherical KMeans) proposedTop-10 accuracy0.94Information Retrieval · index=partitioned inverted-index IVF · encoder=SPLADE · clustering=spherical KMeans · partitioning=Weak Sinnamon · documents-evaluated=about 10%Bridging Dense and Sparse Maximum Inner Product Search
Source quote
L1391: of 0.94 by merely evaluating, on average, about 10% of the total number of documents in
2023GAVA-SDA (θ=0.9) proposedAccuracy0.877Question Answering · k=5 · theta=0.9Learning Answer Generation using Supervision from Automatic Question Answering Evaluators
Source quote
L153: (Ours) GAVA-SDA │ 0.868 │ 0.498 │ 0.877 │ 0.869 │ +8.55% │ -1.48%
2023GenQA-WS baselineAccuracy0.775Question Answering · k=5Learning Answer Generation using Supervision from Automatic Question Answering Evaluators
Source quote
L152: \multicolumn{1}{c}{GAVA-Score} GenQA-WS~\cite{gabburo2022} │ 0.655 │ 0.409 │ 0.775 │ 0.770 │ Baseline │ Baseline
2022BERTimbau proposed non-standard sliceTest Accuracy99.8 %Question Answering · split: test · subset=biomedical · language=PortugueseIntegrating question answering and text-to-SQL in Portuguese
Source quote
L155: 99.8 % │ 98.0% │ 99.6%