MRI motion correction

2 papers · 4 extracted observations · motion correction · Markdown · CSV · JSON API

Also indexed as: mri-motion-correction

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2021UP-GAN without uncertainty-based guidance ablationSSIM0.92variant=without uncertainty-based guidanceUncertainty-Guided Progressive GANs for Medical Image Translation
Source quote
L183: (0.87/25.4/40.7), (0.93/27.3/38.7), and (0.92/26.2/35.1) for PET to CT translation, undersampled MRI reconstruction, and MRI motion correction, respectively.
2021UP-GAN without uncertainty-based guidance ablationPSNR26.2variant=without uncertainty-based guidanceUncertainty-Guided Progressive GANs for Medical Image Translation
Source quote
L183: (0.87/25.4/40.7), (0.93/27.3/38.7), and (0.92/26.2/35.1) for PET to CT translation, undersampled MRI reconstruction, and MRI motion correction, respectively.
2017LAP + ∇h proposedCPU time4.32e2 salpha=0.01 · noise=5% · bounds=none · regularizer=discrete-gradient · realizations=10LAP: a Linearize and Project Method for Solving Inverse Problems with Coupled Variables
Source quote
L434: LAP + \nabla_h │ {\bf 76.2} │ 3.74e-3 │ 1.67e-4 │ 3.62e2 │ {\bf 4.32e2}
2017VarPro + ∇h baselineCPU time1.52e4 salpha=0.01 · noise=5% · bounds=none · regularizer=discrete-gradient · realizations=10LAP: a Linearize and Project Method for Solving Inverse Problems with Coupled Variables
Source quote
L436: VarPro + \nabla_h │ 115.9 │ 7.92e-2 │ 4.33e-2 │ 2.19e4 │ 1.52e4