MMWHS

31 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

3.43.74.04.320212022MPSCL: 3.47 (2021)MPSCL: 3.8 (2021)Proposed UDA method (Ours, with SSM): 4.2 (2022)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 40 of 40 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025DDFP (DeepLab) proposedAverage Dice0.7981split: test · source-free-domain-adaptation · backbone=DeepLab · adaptation-direction=CT→MRIDDFP: Data-dependent Frequency Prompt for Source Free Domain Adaptation of Medical Image Segmentation
Source quote
L271: DDFP (ours) │ 0.7607 │ 0.8309 │ 0.9028 │ 0.6982 │ 0.7981 │ 2.2280 │ 2.2149 │ 2.2343 │ 5.0821 │ 2.9398
2025ImplicitMeshNet proposedDice score0.924split: testDeep Implicit Neural Representations for End-to-End Anatomical Shape Estimation from Volumetric Images
Source quote
L59: 0.924
2025ImplicitMeshNet proposedDice score0.921split: testDeep Implicit Neural Representations for End-to-End Anatomical Shape Estimation from Volumetric Images
Source quote
L60: 0.921
2025Proposed unified framework (Ours: RW-DVNet, CDP, WCCE) proposedAverage Dice91.1aggregation=average across AA, LAC, LVC, and MYO · modality-direction=MR-to-CTA Unified Degradation-Robust Approach to SSL and UDA for 3D Medical Images
Source quote
L352: 91.1
2024S&D-Messenger proposedAverage Dice91.4classes=AA, LAC, LVC, MYO · backbone=SegFormer-B5 · protocol=UMDA · transfer-direction=MR-to-CTS&D Messenger: Exchanging Semantic and Domain Knowledge for Generic Semi-Supervised Medical Image Segmentation
Source quote
L289: Ours │ 88.9 │ 94.1 │ 88.5 │ 94.2 │ 91.4 │ 1.4
2024MulModSeg (UNet backbone) proposedAverage Dice score92.72split: test · backbone=UNet · training-data=20 MR scans and 10 CT scans · target-modality=CTMulModSeg: Enhancing Unpaired Multi-Modal Medical Image Segmentation with Modality-Conditioned Text Embedding and Alternating Training
Source quote
L311: In benchmarking the performance of our MulModSeg framework against several state-of-the-art methods for cross-modality medical image segmentation on the MMWHS dataset, we observed significant improvements across most of the heart substructures. As shown in \Cref{tab: comp_sota_MMWHS}, our method was evaluated using both the UNet and SwinUNETR backbones, with an emphasis on the target modality (CT). MulModSeg achieved the highest average Dice scores of 92.72 for the UNet backbone and 93.31 for the SwinUNETR backbone. These results underscore the effectiveness of our approach in leveraging modality-conditioned text embeddings and the ALT procedure. Specifically, our framework demonstrated remarkable improvements in segmenting critical cardiac substructures such as the MY, RA, and RV. For instance, with the UNet backbone, MulModSeg achieved Dice scores of 92.32 for MY, 93.42 for RA, and 94.80 for RV, surpassing previous methods by a considerable margin. Similarly, with the SwinUNETR backbone, our method attained Dice scores of 93.15 for MY, 92.20 for RA, and 95.63 for RV, indicating consistent performance enhancements across different architectural setups. These results highlight the robustness and superior performance of our method, attributed to the innovative use of modality-conditioned text embeddings and the ALT procedure, which enhance the model's ability to leverage information from unpaired multi-modal datasets.
2024MulModSeg (SwinUNETR backbone) proposedAverage Dice score93.31split: test · backbone=SwinUNETR · training-data=20 MR scans and 10 CT scans · target-modality=CTMulModSeg: Enhancing Unpaired Multi-Modal Medical Image Segmentation with Modality-Conditioned Text Embedding and Alternating Training
Source quote
L311: In benchmarking the performance of our MulModSeg framework against several state-of-the-art methods for cross-modality medical image segmentation on the MMWHS dataset, we observed significant improvements across most of the heart substructures. As shown in \Cref{tab: comp_sota_MMWHS}, our method was evaluated using both the UNet and SwinUNETR backbones, with an emphasis on the target modality (CT). MulModSeg achieved the highest average Dice scores of 92.72 for the UNet backbone and 93.31 for the SwinUNETR backbone. These results underscore the effectiveness of our approach in leveraging modality-conditioned text embeddings and the ALT procedure. Specifically, our framework demonstrated remarkable improvements in segmenting critical cardiac substructures such as the MY, RA, and RV. For instance, with the UNet backbone, MulModSeg achieved Dice scores of 92.32 for MY, 93.42 for RA, and 94.80 for RV, surpassing previous methods by a considerable margin. Similarly, with the SwinUNETR backbone, our method attained Dice scores of 93.15 for MY, 92.20 for RA, and 95.63 for RV, indicating consistent performance enhancements across different architectural setups. These results highlight the robustness and superior performance of our method, attributed to the innovative use of modality-conditioned text embeddings and the ALT procedure, which enhance the model's ability to leverage information from unpaired multi-modal datasets.
2023ARCO-SAG proposedaveraged Dice86.1%semi-supervised · labeled-data=1%Rethinking Semi-Supervised Medical Image Segmentation: A Variance-Reduction Perspective
Source quote
L187: Our \texttt{ARCO-SAG}\xspace achieves \{84.9%, 87.1%, 88.5%\}, \{64.1%, 67.3%, 69.4%\}, \{86.1%, 88.6%, 89.3%\}, \{91.5%, 92.5%, 92.6%\}, \{73.2%, 86.9%, 89.1%\} in averaged Dice across ACDC, LiTS, MMWHS, MP-MRI, and LA.
2023AdaAtlas-Norm proposedaverage Dice score0.7961split: testPay Attention to the Atlas: Atlas-Guided Test-Time Adaptation Method for Robust 3D Medical Image Segmentation
Source quote
L144: AdaAtlas-Norm(ours) │ 0.7961~\textcolor{gray}{(+4.0%)} │ 0.7264~\textcolor{gray}{(+45.6%)}
2023AdaAtlas-Attention proposedaverage Dice score0.8013split: testPay Attention to the Atlas: Atlas-Guided Test-Time Adaptation Method for Robust 3D Medical Image Segmentation
Source quote
L145: AdaAtlas-Attention(ours) │ 0.8013~\textcolor{gray}{(+4.7%)} │ 0.7488~\textcolor{gray}{(+50.1%)}
2023MACL proposedHD955.91fine-tuned · pretraining=CHD (CT) · labeled-data=10%Multi-level Asymmetric Contrastive Learning for Medical Image Segmentation Pre-training
Source quote
L456: Our proposed MACL also achieves the lowest (best) HD95, such as 5.23 on ACDC, 5.91 on MMWHS and 22.38 on HVSMR, 6.93 on Spleen and 21.53 on ISIC.
2023A&D proposedAverage Dice90.1unsupervised-domain-adaptation · source-domain=MR · target-domain=CTTowards Generic Semi-Supervised Framework for Volumetric Medical Image Segmentation
Source quote
L342: A\ │ D (ours) │ 93.2 │ 89.5 │ 91.7 │ 86.2 │ 90.1 │ 1.7
2023SynthMix proposedAverage Dice67.5%domain-adaptation · direction=CT-to-MRSynthMix: Mixing up Aligned Synthesis for Medical Cross-Modality Domain Adaptation
Source quote
L119: Ours │ 70.0 │ 68.7 │ 83.0 │ 48.3 │ 67.5
2023SynthMix proposedAverage ASSD4.6domain-adaptation · direction=CT-to-MRSynthMix: Mixing up Aligned Synthesis for Medical Cross-Modality Domain Adaptation
Source quote
L126: Ours │ 5.9 │ 5.1 │ 3.3 │ 4.1 │ 4.6
2023fairLD with SL proposedDice (average of four categories)0.4136source-free-domain-adaptation · epoch=50 · adaptation-direction=CT-to-MRISL: Stable Learning in Source-Free Domain Adaption for Medical Image Segmentation
Source quote
L169: fairLD with SL(ours) │ 0.4073 │ 0.4124 │ 0.4150 │ 0.4171 │ 0.4165 │ 0.4101 │ 0.4136 │ 0.4264(epoch 13)
2023DPL with SL proposedDice (average of four categories)0.4213source-free-domain-adaptation · epoch=50 · adaptation-direction=CT-to-MRISL: Stable Learning in Source-Free Domain Adaption for Medical Image Segmentation
Source quote
L170: DPL with SL (ours) │ 0.4109 │ 0.4076 │ 0.4154 │ 0.4174 │ 0.4151 │ 0.4177 │ 0.4213 │ 0.4238(epoch 44)
2023fairLD with SL proposedDice (average of four categories)0.6223source-free-domain-adaptation · epoch=50 · adaptation-direction=MRI-to-CTSL: Stable Learning in Source-Free Domain Adaption for Medical Image Segmentation
Source quote
L182: fairLD with SL(ours) │ 0.5772 │ 0.5816 │ 0.5934 │ 0.6213 │ 0.6211 │ 0.6119 │ 0.6223 │ 0.6289(epoch 28)
2022Ours (w/ CR; Joint V3 with both consistency regularizers) proposedDice coefficient, overall mean91.4%split: test · backbone=2D Swin-Unet · modalities=CT and MRIToward Unpaired Multi-modal Medical Image Segmentation via Learning Structured Semantic Consistency
Source quote
L475: Ours (w/ CR) │ 90.9±2.0 │ 94.8±1.6 │ 94.5±2.1 │ 95.9±1.4 │ 94.0 (\textcolor[RGB]{254,76,97}{+2.7}) │ 81.6±2.5 │ 89.6±3.3 │ 94.4±1.3 │ 89.2±2.8 │ 88.7 (\textcolor[RGB]{254,76,97}{+2.2}) │ 91.4 (\textcolor[RGB]{254,76,97}{+2.5}) \specialrule{0.05em}{0pt}{3pt}
2022Proposed UDA method (Ours, with SSM) proposedAverage Dice80.8%split: test · unsupervised-domain-adaptation · domain-adaptation=MR-to-CT · metric-aggregation=average across AA, LAC, LVC, and MYOEnhancing Unsupervised Domain Adaptation via Semantic Similarity Constraint for Medical Image Segmentation
Source quote
L434: 80.8
2022Proposed UDA method (Ours, with SSM) proposedAverage ASD4.2split: test · unsupervised-domain-adaptation · domain-adaptation=MR-to-CT · metric-aggregation=average across AA, LAC, LVC, and MYOEnhancing Unsupervised Domain Adaptation via Semantic Similarity Constraint for Medical Image Segmentation
Source quote
L439: 4.2
2022CRNP proposedDice0.9193modality=CTUncertainty-Aware Multi-modal Learning via Cross-Modal Random Network Prediction
Source quote
L249: Ours │ 0.9193 │ 0.8486
2022CRNP proposedDice0.8758modality=MRUncertainty-Aware Multi-modal Learning via Cross-Modal Random Network Prediction
Source quote
L250: 0.8758 │ 0.7814
2022Proposed method (RCS + DTS + fuzzy fusion) proposedAverage DSC0.626semi-supervised · labeled-data=10%Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRI
Source quote
L149: \multicolumn{1}{c|}{0.626}
2022Proposed method (RCS + DTS + fuzzy fusion) proposedAverage DSC0.815semi-supervised · labeled-data=40%Addressing Class Imbalance in Semi-supervised Image Segmentation: A Study on Cardiac MRI
Source quote
L151: 0.815
2022TTAS_{\mathcal{RC}} proposedMean 3D DSC80.0%split: test · test-time-adaptation · domain=MRI-to-CTTest-Time Adaptation with Shape Moments for Image Segmentation
Source quote
L158: \textbf{TTAS_{\mathcal{RC}}} (Ours) │ × │ × │ \checkmark │ 85.1 │ 82.6 │ 79.3 │ 73.2 │ 80.0 │ 5.6 │ 4.3 │ 6.1 │ 5.3 │ 5.3
2022VectorPOSE proposedclass-averaged Dice score83.30%modality=CTA Point in the Right Direction: Vector Prediction for Spatially-Aware Self-Supervised Volumetric Representation Learning
Source quote
L184: 83.30 │ 89.43 │ 91.27 │ 91.60
2021MPSCL proposedAverage Dice84.08%unsupervised-domain-adaptation · source-domain=cardiac MRI · target-domain=cardiac CTMargin Preserving Self-paced Contrastive Learning Towards Domain Adaptation for Medical Image Segmentation
Source quote
L340: MPSCL │ 90.26 │ 87.08 │ 86.45 │ 72.51 │ 84.08 │ 3.47 │ 3.16 │ 2.85 │ 3.41 │ 3.47
2021MPSCL proposedAverage ASD3.47unsupervised-domain-adaptation · source-domain=cardiac MRI · target-domain=cardiac CTMargin Preserving Self-paced Contrastive Learning Towards Domain Adaptation for Medical Image Segmentation
Source quote
L340: MPSCL │ 90.26 │ 87.08 │ 86.45 │ 72.51 │ 84.08 │ 3.47 │ 3.16 │ 2.85 │ 3.41 │ 3.47
2021MPSCL proposedAverage Dice69.87%unsupervised-domain-adaptation · source-domain=cardiac CT · target-domain=cardiac MRIMargin Preserving Self-paced Contrastive Learning Towards Domain Adaptation for Medical Image Segmentation
Source quote
L375: MPSCL │ 64.66 │ 77.34 │ 81.61 │ 55.90 │ 69.87 │ 5.59 │ 2.64 │ 3.44 │ 3.50 │ 3.80
2021MPSCL proposedAverage ASD3.80unsupervised-domain-adaptation · source-domain=cardiac CT · target-domain=cardiac MRIMargin Preserving Self-paced Contrastive Learning Towards Domain Adaptation for Medical Image Segmentation
Source quote
L375: MPSCL │ 64.66 │ 77.34 │ 81.61 │ 55.90 │ 69.87 │ 5.59 │ 2.64 │ 3.44 │ 3.50 │ 3.80
2021BiGL proposedDSC, Avg.75.3%split: test · unsupervised-domain-adaptation · source-modality=MR · target-modality=CTCross-Modality Brain Tumor Segmentation via Bidirectional Global-to-Local Unsupervised Domain Adaptation
Source quote
L306: BiGL (Ours) │ 62.0 │ 71.1 │ 88.0 │ 43.7 │ 66.2 │ 87.7 │ 78.6 │ 80.0 │ 54.9 │ 75.3
2021AdaMI proposedMean DSC across AA, LA, LV, and MYO75.7%split: test · source-free · backbone=UNet · structures=AA, LA, LV, MYO · target-tags=used · source-domain=MRI · target-domain=CTSource-free domain adaptation for image segmentation
Source quote
L342: AdaMI (Ours) │ \checkmark │ \checkmark │ 83.1 │ 78.2 │ 74.5 │ 66.8 │ 75.7 │ 5.6 │ 4.2 │ 5.7 │ 6.9 │ 5.6
2021global+local(block) (proposed) proposedaverage Dice score0.553split: test · labeled-training-data=20%Semi-supervised Contrastive Learning for Label-Efficient Medical Image Segmentation
Source quote
L179: global+local(block) │ 0.824 │ 0.849 │ 0.866 │ 0.382 │ 0.553 │ 0.764
2021global+local(block) (proposed) proposedaverage Dice score0.764split: test · labeled-training-data=40%Semi-supervised Contrastive Learning for Label-Efficient Medical Image Segmentation
Source quote
L179: global+local(block) │ 0.824 │ 0.849 │ 0.866 │ 0.382 │ 0.553 │ 0.764
2020G^D encoder + L^R decoder (d_l=3) proposedMean Dice score (DSC)0.694split: test · fine-tuned · decoder-depth=3 · labeled-volumes=2 · decoder-pretraining=L^RContrastive learning of global and local features for medical image segmentation with limited annotations
Source quote
L508: {G (D)} │ {L (R)} │ 0.556 │ 0.569 │ 0.572 │ 0.671 │ 0.694 │ 0.693 │ 0.796 │ 0.794 │ 0.796
2020G^D encoder + random-initialized decoder proposedMean Dice score (DSC)0.686split: test · fine-tuned · decoder=random-initialized · labeled-volumes=2Contrastive learning of global and local features for medical image segmentation with limited annotations
Source quote
L506: {G (D)} │ {random init} │ MMWHS │ \multicolumn{3}{|l|}{0.553} │ \multicolumn{3}{|l|}{0.686} │ \multicolumn{3}{|l|}{0.793}
2019Proposed framework (error map prediction) proposedDice score0.626split: val · cross-validation=5-foldA Fine-Grain Error Map Prediction and Segmentation Quality Assessment Framework for Whole-Heart Segmentation
Source quote
L4: When introducing advanced image computing algorithms, e.g., whole-heart segmentation, into clinical practice, a common suspicion is how reliable the automatically computed results are. In fact, it is important to find out the failure cases and identify the misclassified pixels so that they can be excluded or corrected for the subsequent analysis or diagnosis. However, it is not a trivial problem to predict the errors in a segmentation mask when ground truth (usually annotated by experts) is absent. In this work, we attempt to address the pixel-wise error map prediction problem and the per-case mask quality assessment problem using a unified deep learning (DL) framework. Specifically, we first formalize an error map prediction problem, then we convert it to a segmentation problem and build a DL network to tackle it. We also derive a quality indicator (QI) from a predicted error map to measure the overall quality of a segmentation mask. To evaluate the proposed framework, we perform extensive experiments on a public whole-heart segmentation dataset, i.e., MICCAI 2017 MMWHS. By 5-fold cross validation, we obtain an overall Dice score of 0.626 for the error map prediction task, and observe a high Pearson correlation coefficient (PCC) of 0.972 between QI and the actual segmentation accuracy (Acc), as well as a low mean absolute error (MAE) of 0.0048 between them, which evidences the efficacy of our method in both error map prediction and quality assessment.
2019Proposed framework (quality indicator, QI) proposedPearson correlation coefficient (PCC)0.972split: val · cross-validation=5-foldA Fine-Grain Error Map Prediction and Segmentation Quality Assessment Framework for Whole-Heart Segmentation
Source quote
L4: When introducing advanced image computing algorithms, e.g., whole-heart segmentation, into clinical practice, a common suspicion is how reliable the automatically computed results are. In fact, it is important to find out the failure cases and identify the misclassified pixels so that they can be excluded or corrected for the subsequent analysis or diagnosis. However, it is not a trivial problem to predict the errors in a segmentation mask when ground truth (usually annotated by experts) is absent. In this work, we attempt to address the pixel-wise error map prediction problem and the per-case mask quality assessment problem using a unified deep learning (DL) framework. Specifically, we first formalize an error map prediction problem, then we convert it to a segmentation problem and build a DL network to tackle it. We also derive a quality indicator (QI) from a predicted error map to measure the overall quality of a segmentation mask. To evaluate the proposed framework, we perform extensive experiments on a public whole-heart segmentation dataset, i.e., MICCAI 2017 MMWHS. By 5-fold cross validation, we obtain an overall Dice score of 0.626 for the error map prediction task, and observe a high Pearson correlation coefficient (PCC) of 0.972 between QI and the actual segmentation accuracy (Acc), as well as a low mean absolute error (MAE) of 0.0048 between them, which evidences the efficacy of our method in both error map prediction and quality assessment.
2019Proposed framework (quality indicator, QI) proposedMean absolute error (MAE)0.0048split: val · cross-validation=5-foldA Fine-Grain Error Map Prediction and Segmentation Quality Assessment Framework for Whole-Heart Segmentation
Source quote
L4: When introducing advanced image computing algorithms, e.g., whole-heart segmentation, into clinical practice, a common suspicion is how reliable the automatically computed results are. In fact, it is important to find out the failure cases and identify the misclassified pixels so that they can be excluded or corrected for the subsequent analysis or diagnosis. However, it is not a trivial problem to predict the errors in a segmentation mask when ground truth (usually annotated by experts) is absent. In this work, we attempt to address the pixel-wise error map prediction problem and the per-case mask quality assessment problem using a unified deep learning (DL) framework. Specifically, we first formalize an error map prediction problem, then we convert it to a segmentation problem and build a DL network to tackle it. We also derive a quality indicator (QI) from a predicted error map to measure the overall quality of a segmentation mask. To evaluate the proposed framework, we perform extensive experiments on a public whole-heart segmentation dataset, i.e., MICCAI 2017 MMWHS. By 5-fold cross validation, we obtain an overall Dice score of 0.626 for the error map prediction task, and observe a high Pearson correlation coefficient (PCC) of 0.972 between QI and the actual segmentation accuracy (Acc), as well as a low mean absolute error (MAE) of 0.0048 between them, which evidences the efficacy of our method in both error map prediction and quality assessment.
2019Proposed method (Ours sampling + Ours reconstruction; SampleNet + ReconNet) proposedPSNR34.22split: testSelf-Supervised Deep Active Accelerated MRI
Source quote
L938: \multirow{ -4}{*}{{\it Cardiac}} │ Ours │ 27.91 │ 32.56 │ 29.00 │ 34.22