MMWHS
31 papers · 83 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↓ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MPSCL SOTA frontier (+1 variant) | 3.47 | 2021-03-01 | source-domain=cardiac MRI · target-domain=cardiac CT · UDA transfer from cardiac MRI to cardiac CT; average over AA, LAC, LVC, and MYO. | Margin Preserving Self-paced Contrastive Learning Towards Domain Adaptation for Medical Image SegmentationSource quoteMPSCL │ 90.26 │ 87.08 │ 86.45 │ 72.51 │ 84.08 │ 3.47 │ 3.16 │ 2.85 │ 3.41 │ 3.47 |
| 2 | Proposed UDA method (Ours, with SSM) | 4.2 | 2022-01-01 | domain-adaptation=MR-to-CT · metric-aggregation=average across AA, LAC, LVC, and MYO · Unsupervised MR-to-CT adaptation; average across AA, LAC, LVC, and MYO; 20% test spli… | Enhancing Unsupervised Domain Adaptation via Semantic Similarity Constraint for Medical Image SegmentationSource quote4.2 |
Metricaverage dice (17)average dsc (9)average dice score (8)dice average of four categories (6)dice score (5)average asd (4)
Regimeunsupervised-domain-adaptation (12)source-free-domain-adaptation (9)semi-supervised (8)domain-adaptation (6)fine-tuned (4)test-time-adaptation (2)
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2023 | MACL proposed | HD95 | 5.91 | fine-tuned · pretraining=CHD (CT) · labeled-data=10% | Multi-level Asymmetric Contrastive Learning for Medical Image Segmentation Pre-trainingSource quoteL456: Our proposed MACL also achieves the lowest (best) HD95, such as 5.23 on ACDC, 5.91 on MMWHS and 22.38 on HVSMR, 6.93 on Spleen and 21.53 on ISIC. |
| 2020 | G^D encoder + L^R decoder (d_l=3) proposed | Mean Dice score (DSC) | 0.694 | split: test · fine-tuned · decoder-depth=3 · labeled-volumes=2 · decoder-pretraining=L^R | Contrastive learning of global and local features for medical image segmentation with limited annotationsSource quoteL508: {G (D)} │ {L (R)} │ 0.556 │ 0.569 │ 0.572 │ 0.671 │ 0.694 │ 0.693 │ 0.796 │ 0.794 │ 0.796 |
| 2020 | G^D encoder + random-initialized decoder proposed | Mean Dice score (DSC) | 0.686 | split: test · fine-tuned · decoder=random-initialized · labeled-volumes=2 | Contrastive learning of global and local features for medical image segmentation with limited annotationsSource quoteL506: {G (D)} │ {random init} │ MMWHS │ \multicolumn{3}{|l|}{0.553} │ \multicolumn{3}{|l|}{0.686} │ \multicolumn{3}{|l|}{0.793} |