MIMIC-III

279 papers · 914 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

-0.00.30.60.9201820222026SAnD: 0.316 (2018)G-BERT: 0.696 (2019)VecoCare: 0.2646 (2023)CORE on Med2Vec: 0.605 (2023)WinIT: 0.038 (2024)FDTempExplainer: 0.043 (2024)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.4444 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.5801 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.5957 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6183 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6554 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6802 (2025)cDEEP: 0.194 (2025)cDEEP: 0.852 (2025)KAMELEON-XGBoost: 0.65 (2025)KnowRare: 0.716 (2026)KnowRare: 0.744 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 2 of 2 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023PLM-ICD (previously reported) baselineMacro F112.7%split: fullAutomated Medical Coding on MIMIC-III and MIMIC-IV: A Critical Review and Replicability Study
Source quote
L381: We demonstrated that the macro F1 score had been underestimated in prior works due to the poorly sampled MIMIC-III full split and the practice of setting the F1 score of all codes absent in the test set to 0. Since 54% of the codes in MIMIC-III full are missing in the test set, the maximum possible macro F1 score is 46%. The previously highest reported macro F1 score on MIMIC-III full is 12.7% for PLM-ICD~\cite{kimReadAttendCode2021}. Using our corrected macro F1 score on the same split, PLM-ICD achieved a macro F1 score of 22.8%. This large difference from previous state-of-the-art seems to indicate that all previous work on AMC used the sub-optimally calculated macro F1 score, including works not reproduced in this paper. Many studies use the macro F1 score to evaluate the ability of their models to predict rare codes \cite{kimReadAttendCode2021, yuanCodeSynonymsMatter2022}. If it has indeed been incorrectly calculated in these studies, some conclusions drawn in previous work regarding rare code prediction may have been misguided.
2023PLM-ICD (corrected evaluation) baselineCorrected Macro F122.8%split: fullAutomated Medical Coding on MIMIC-III and MIMIC-IV: A Critical Review and Replicability Study
Source quote
L381: We demonstrated that the macro F1 score had been underestimated in prior works due to the poorly sampled MIMIC-III full split and the practice of setting the F1 score of all codes absent in the test set to 0. Since 54% of the codes in MIMIC-III full are missing in the test set, the maximum possible macro F1 score is 46%. The previously highest reported macro F1 score on MIMIC-III full is 12.7% for PLM-ICD~\cite{kimReadAttendCode2021}. Using our corrected macro F1 score on the same split, PLM-ICD achieved a macro F1 score of 22.8%. This large difference from previous state-of-the-art seems to indicate that all previous work on AMC used the sub-optimally calculated macro F1 score, including works not reproduced in this paper. Many studies use the macro F1 score to evaluate the ability of their models to predict rare codes \cite{kimReadAttendCode2021, yuanCodeSynonymsMatter2022}. If it has indeed been incorrectly calculated in these studies, some conclusions drawn in previous work regarding rare code prediction may have been misguided.