MIMIC-III

279 papers · 914 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

-0.00.30.60.9201820222026SAnD: 0.316 (2018)G-BERT: 0.696 (2019)VecoCare: 0.2646 (2023)CORE on Med2Vec: 0.605 (2023)WinIT: 0.038 (2024)FDTempExplainer: 0.043 (2024)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.4444 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.5801 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.5957 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6183 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6554 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6802 (2025)cDEEP: 0.194 (2025)cDEEP: 0.852 (2025)KAMELEON-XGBoost: 0.65 (2025)KnowRare: 0.716 (2026)KnowRare: 0.744 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 3 of 3 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026M2AE biosignal fingerprints proposedAUROC0.877linear-probe · classes=binary · input-modality=ECG+PPGBiosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model
Source quote
L130: On the hypertension identification task, arguably the most clinically impactful result in this work, biosignal fingerprints demonstrated a substantial advantage over all baselines, achieving an AUPRC of 0.882 and AUROC of 0.877. This represents an improvement of 8.5% in F1-score over the second-best method, ECG-FM \ │ PaPaGei, and 31.9% over the weakest baseline, MOMENT. An AUROC of 0.877 for hypertension detection from short wearable biosignal segments is clinically significant: conventional hypertension screening relies on cuff-based blood pressure measurement, which is episodic and subject to white-coat effects, whereas a model operating at this performance level from passively acquired PPG and ECG signals could enable continuous, unobtrusive population-scale screening. The UMAP visualization for this task is appended in Appendix Fig.~\ref{appfig:umap_hyp}.
2025SMI proposedAUROC65.32%split: test · linear-probe · split-ratio=80/20 · representation=mean-pooled SMI ICD-code embeddingsSMI: Semantic Medical ID for Hierarchy-Aware Concept Representation
Source quote
L195: As shown in Table 3, SMI achieves higher predictive performance than BioBERT across both mortality and readmission prediction tasks. Specifically, SMI improves AUROC and AUPRC in mortality prediction (65.32% and 31.58%) compared to BioBERT (60.38% and 28.33%). Notably, our SMI approach requires no additional encoding or fine-tuning, but it simply applies mean pooling of precomputed semantic embeddings. This demonstrates that the hierarchical semantics embedded in SMI enhance clinical representation, leading to more discriminative modeling. These findings
2025BioBERT baselineAUROC60.38%split: test · linear-probe · split-ratio=80/20 · representation=BioBERT [CLS] embeddingsSMI: Semantic Medical ID for Hierarchy-Aware Concept Representation
Source quote
L195: As shown in Table 3, SMI achieves higher predictive performance than BioBERT across both mortality and readmission prediction tasks. Specifically, SMI improves AUROC and AUPRC in mortality prediction (65.32% and 31.58%) compared to BioBERT (60.38% and 28.33%). Notably, our SMI approach requires no additional encoding or fine-tuning, but it simply applies mean pooling of precomputed semantic embeddings. This demonstrates that the hierarchical semantics embedded in SMI enhance clinical representation, leading to more discriminative modeling. These findings