MIMIC-III

279 papers · 914 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

-0.00.30.60.9201820222026SAnD: 0.316 (2018)G-BERT: 0.696 (2019)VecoCare: 0.2646 (2023)CORE on Med2Vec: 0.605 (2023)WinIT: 0.038 (2024)FDTempExplainer: 0.043 (2024)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.4444 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.5801 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.5957 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6183 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6554 (2025)Mortality multimodal architecture with interpolation-based embeddings and time-aware attention: 0.6802 (2025)cDEEP: 0.194 (2025)cDEEP: 0.852 (2025)KAMELEON-XGBoost: 0.65 (2025)KnowRare: 0.716 (2026)KnowRare: 0.744 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 52 of 52 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Two-sided instruction proposedAUPRC30.2%model=gpt-oss-120b · params=120b · response-mode=two-sided instructionTRIAGE: Dialectical Reasoning for Explainable Risk Prediction on Irregularly Sampled Medical Time Series with LLMs
Source quote
L130: Two-sided │ 75.5 │ 30.2 │ 0.205 │ 0.185
2026TI-SAE (soft) proposedAUPRC.386in-distributionTemporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models
Source quote
L532: .756/.386
2026AdaPCLA proposedAUPRC0.9220-shot · evaluation=cross-population generation without retraining · training-data=MIMIC-IVAdaPCLA: Adaptive Prior-Calibrated Logit Adjustment for Long-Tailed Longitudinal EHR Generation
Source quote
L51: For the zero-shot generation setting based on MIMIC-IV training to MIMIC-III inference, AdaPCLA\xspace reaches AUPRC of \(0.922\) without retraining, outperforming GPT-style generation by 3.5% F1, which verifies the effectiveness of the learned structure for cross-population adaptation.
2026BTM proposedAUPRC0.012ipc=500 · evaluation=cross-architecture · evaluation-backbone=LSTM-1 · condensation-backbone=TCNGeometric Characterisation and Structured Trajectory Surrogates for Clinical Dataset Condensation
Source quote
L789: The transfer setting is more demanding on MIMIC-III, where condensation is performed with a TCN and evaluation includes both TCN and LSTM targets. Here, architecture shift changes the temporal inductive bias of the model, making transfer substantially harder. Even in this setting, BTM remains consistently stronger than DATM across all target architectures. The gains are modest within the TCN family, but larger under transfer to LSTMs, where BTM improves AUPRC by 0.012 and 0.028 on LSTM-1 and LSTM-2, respectively. Relative to its source-architecture performance, BTM also exhibits slightly smaller degradation than DATM under TCN-to-LSTM transfer.
2026BTM proposedAUPRC0.028ipc=500 · evaluation=cross-architecture · evaluation-backbone=LSTM-2 · condensation-backbone=TCNGeometric Characterisation and Structured Trajectory Surrogates for Clinical Dataset Condensation
Source quote
L789: The transfer setting is more demanding on MIMIC-III, where condensation is performed with a TCN and evaluation includes both TCN and LSTM targets. Here, architecture shift changes the temporal inductive bias of the model, making transfer substantially harder. Even in this setting, BTM remains consistently stronger than DATM across all target architectures. The gains are modest within the TCN family, but larger under transfer to LSTMs, where BTM improves AUPRC by 0.012 and 0.028 on LSTM-1 and LSTM-2, respectively. Relative to its source-architecture performance, BTM also exhibits slightly smaller degradation than DATM under TCN-to-LSTM transfer.
2026GraphWalker (black-box variant) proposedAUPRC62.31few-shot · backbone=GPT-5.2 · answer-mode=direct-answer · reasoning-scaffold=noneGraphWalker: Patient Analogy Meets Information Gain for Clinical Reasoning with Large Language Models
Source quote
L1540: \textbf{±std{87.64}{5.14}} │ \textbf{±std{62.31}{8.96}} │ \textbf{±std{64.79}{7.74}}
2026M2AE biosignal fingerprints proposedAUPRC0.882linear-probe · classes=binary · input-modality=ECG+PPGBiosignal Fingerprinting: A Cross-Modal PPG-ECG Foundation Model
Source quote
L130: On the hypertension identification task, arguably the most clinically impactful result in this work, biosignal fingerprints demonstrated a substantial advantage over all baselines, achieving an AUPRC of 0.882 and AUROC of 0.877. This represents an improvement of 8.5% in F1-score over the second-best method, ECG-FM \ │ PaPaGei, and 31.9% over the weakest baseline, MOMENT. An AUROC of 0.877 for hypertension detection from short wearable biosignal segments is clinically significant: conventional hypertension screening relies on cuff-based blood pressure measurement, which is episodic and subject to white-coat effects, whereas a model operating at this performance level from passively acquired PPG and ECG signals could enable continuous, unobtrusive population-scale screening. The UMAP visualization for this task is appended in Appendix Fig.~\ref{appfig:umap_hyp}.
2026Mental-health + SSM proposedAUPRC0.82Binary patient-level risk prediction using mental-health representations with an SSM te…Beyond Physical Illness: Can Clinical Narratives Reveal Emerging Mental Health Risks in Chronically Ill Patients?
Source quote
L204: 0.82
2026Standard (answer-only) baselineAUPRC27.8%model=gpt-oss-120b · params=120b · response-mode=answer-onlyTRIAGE: Dialectical Reasoning for Explainable Risk Prediction on Irregularly Sampled Medical Time Series with LLMs
Source quote
L129: Standard │ 76.1 │ 27.8 │ 0.236 │ 0.211
2026EHR-emb baselineAUPRC48.45few-shot · backbone=GPT-5.2 · answer-mode=direct-answer · reasoning-scaffold=noneGraphWalker: Patient Analogy Meets Information Gain for Clinical Reasoning with Large Language Models
Source quote
L1537: \underline{±std{81.59}{4.87}} │ \underline{±std{48.45}{6.96}} │ \underline{±std{46.07}{5.78}}
2026Clinical Mamba + SSM baselineAUPRC0.62Binary patient-level risk prediction using original Clinical Mamba representations with…Beyond Physical Illness: Can Clinical Narratives Reveal Emerging Mental Health Risks in Chronically Ill Patients?
Source quote
L192: 0.62
2025cDEEP proposedAUPRC0.852split: test · subset=Berlin definition; prediction windows without PaO2/FiO2 excluded (94.4% disregarded)Causally-informed Deep Learning towards Explainable and Generalizable Outcomes Prediction in Critical Care
Source quote
L107: resulting in a relatively low AUROC at 0.688 (CI [0.684-0.692]). Despite the insufficient training data, the percentage of ARDS positive prediction points among the left 5.6% training data is high, we achieve a decent AUPRC 0.852 (CI [0.849-0.855]), validating cDEEP's prediction capability.
2025cDEEP proposedAUPRC0.194split: test · subset=death-positive prediction points: 0.9%Causally-informed Deep Learning towards Explainable and Generalizable Outcomes Prediction in Critical Care
Source quote
L108: The problem of data imbalance is severe for death---only 0.9% death-positive prediction points in the database, which hampers the prediction accuracy. Although high AUROC is achieved (0.906, CI [0.902-0.909]), in the scenarios with imbalance data, AUPRC is a better metric for model evaluation and the AUPRC for death prediction is only 0.194 (CI [0.185-0.204]).
2025DeepSelective proposedAUPRC0.5627Early-stage ICU admission mortality prediction; evaluated on MIMIC-III.DeepSelective: Interpretable prognosis prediction via feature selection and compression in EHR data
Source quote
L400: DeepSelective achieves an AUROC of 0.9054 and an AUPRC of 0.5627, outperforming other models such as GRU-\alpha, RETAIN, and T-LSTM. Notably, DeepSelective’s min(Se, P+) is 0.5218, which is also superior to other models. For the decompensation prediction task, DeepSelective achieves an AUROC of 0.9143, an AUPRC of 0.3203, and a min(Se, P+) of 0.3573, which is also the best model. The experimental results demonstrate that our DeepSelective framework generally outperforms baseline models in terms of AUPRC, AUROC, and min(Se, P+), solidifying its position as a leading tool for predictive modeling in EHR-Based Prognosis Prediction.
2025DeepSelective proposedAUPRC0.3203Real-time decompensation detection; evaluated on MIMIC-III.DeepSelective: Interpretable prognosis prediction via feature selection and compression in EHR data
Source quote
L400: DeepSelective achieves an AUROC of 0.9054 and an AUPRC of 0.5627, outperforming other models such as GRU-\alpha, RETAIN, and T-LSTM. Notably, DeepSelective’s min(Se, P+) is 0.5218, which is also superior to other models. For the decompensation prediction task, DeepSelective achieves an AUROC of 0.9143, an AUPRC of 0.3203, and a min(Se, P+) of 0.3573, which is also the best model. The experimental results demonstrate that our DeepSelective framework generally outperforms baseline models in terms of AUPRC, AUROC, and min(Se, P+), solidifying its position as a leading tool for predictive modeling in EHR-Based Prognosis Prediction.
2025KAMELEON-XGBoost proposedAUPRC0.650split: test · input-modality=multimodal · split-strategy=80:20 patient-disjointImproving Hospital Risk Prediction with Knowledge-Augmented Multimodal EHR Modeling
Source quote
L107: KAMELEON{}-{XGBoost} │ \istrue │ \istrue │ 0.920 │ 0.920 │ 0.790 │ 0.980 │ 0.369 │ 0.660 │ 0.920 │ 0.650
2025KnowRare proposedAUPRC0.744split: test · input-window=final 48 hours of hospital admission · adaptation-subset=10% of conditions · prediction-horizon=90 days post-dischargeBridging data gaps of rare conditions in ICU: a multi-disease adaptation approach for clinical prediction
Source quote
L77: KnowRare (Ours) │ 0.744 (0.051) │ 0.797 (0.032) │ 0.716(0.031) │ 0.749 (0.034) │ 0.709(0.022) │ 0.757 (0.012) │ 0.206 (0.024) │ 0.509 (0.030) │ 0.244 (0.039) │ 0.609 (0.044)
2025KnowRare proposedAUPRC0.716split: test · input-window=final 48 hours of hospital admission · adaptation-subset=10% of conditions · prediction-horizon=30 days post-dischargeBridging data gaps of rare conditions in ICU: a multi-disease adaptation approach for clinical prediction
Source quote
L77: KnowRare (Ours) │ 0.744 (0.051) │ 0.797 (0.032) │ 0.716(0.031) │ 0.749 (0.034) │ 0.709(0.022) │ 0.757 (0.012) │ 0.206 (0.024) │ 0.509 (0.030) │ 0.244 (0.039) │ 0.609 (0.044)
2025Mortality multimodal architecture with interpolation-based embeddings and time-aware attention proposedAUPRC0.6802split: test · subgroup=middle age (>45)One Size Fits None: Rethinking Fairness in Medical AI
Source quote
L246: Middle Age (>45) │ 0.6802 │ [0.5639, 0.7830]
2025Mortality multimodal architecture with interpolation-based embeddings and time-aware attention proposedAUPRC0.5957split: test · subgroup=high age (>75)One Size Fits None: Rethinking Fairness in Medical AI
Source quote
L247: High Age (>75) │ 0.5957 │ [0.5050, 0.6830]
2025Mortality multimodal architecture with interpolation-based embeddings and time-aware attention proposedAUPRC0.6554split: test · subgroup=maleOne Size Fits None: Rethinking Fairness in Medical AI
Source quote
L248: Male │ 0.6554 │ [0.5920, 0.7170]
2025Mortality multimodal architecture with interpolation-based embeddings and time-aware attention proposedAUPRC0.5801split: test · subgroup=femaleOne Size Fits None: Rethinking Fairness in Medical AI
Source quote
L249: Female │ 0.5801 │ [0.5039, 0.6610]
2025Mortality multimodal architecture with interpolation-based embeddings and time-aware attention proposedAUPRC0.6183split: test · subgroup=whiteOne Size Fits None: Rethinking Fairness in Medical AI
Source quote
L250: White │ 0.6183 │ [0.5600, 0.6730]
2025Mortality multimodal architecture with interpolation-based embeddings and time-aware attention proposedAUPRC0.4444split: test · subgroup=blackOne Size Fits None: Rethinking Fairness in Medical AI
Source quote
L251: Black │ 0.4444 │ [0.2320, 0.6341]
2025LightGBM baselineAUPRC0.534split: test · input-modality=structured · split-strategy=80:20 patient-disjointImproving Hospital Risk Prediction with Knowledge-Augmented Multimodal EHR Modeling
Source quote
L91: LightGBM \cite{jamiaopen} │ \istrue │ \isfalse │ 0.890 │ 0.930 │ 0.510 │ 0.940 │ 0.480 │ 0.720 │ 0.866 │ 0.534
2024FDTempExplainerAUPRC-drop (k=50)0.043split: testExplain Temporal Black-Box Models via Functional Decomposition
Source quote
L414: 0.043
2024WinITAUPRC-drop (k=50)0.038split: testExplain Temporal Black-Box Models via Functional Decomposition
Source quote
L404: 0.038
2023MMUGL proposedAuPRC45.27horizon=30-dayMulti-modal Graph Learning over UMLS Knowledge Graphs
Source quote
L349: \tableref{tab:concept-embedding-ablation} shows performance at a relevant 1 year horizon \citep{sparra-liley-medrxiv21}. At a 15-day horizon we outperform very recent results by GraphCare~\citep{graphcare-jiang-arxiv23} using language model enhanced knowledge graphs who report 69.0 AuROC on MIMIC-III, where we achieve average AuROC of 73.69 with MMUGL (and 71.93 with \emph{MMUGL w/o \mathcal{C}(n)}). MedGTX by~\citet{graph-text-park-chil22} is a large fusion architecture and at a 30-day horizon they report 41.9 AuPRC, we outperform this result with our efficient shared latent space and achieve 45.27 with MMUGL (and 45.57 with \emph{MMUGL w/o \mathcal{C}(n)}).
2023VecoCare proposedma-AUPRC.2646split: test · classes=135VecoCare: Visit Sequences-Clinical Notes Joint Learning for Diagnosis Prediction in Healthcare Data
Source quote
L469: .2646(.012)
2023CORE on Med2Vec proposedAUPRC0.605split: test · backbone=Med2VecToward Cohort Intelligence: A Universal Cohort Representation Learning Framework for Electronic Health Record Analysis
Source quote
L360: \textbf{\quad + CORE{}(Ours)} │ 0.605 │ 59.7% │ 0.593 │ 0.474 │ 0.527 [1pt]
2023Contrastive learning-based imputation-prediction network proposedAUPRC0.4752prediction-horizon=24 hours after ICU admissionContrastive Learning-Based Imputation-Prediction Networks for In-hospital Mortality Risk Modeling Using EHRs
Source quote
L296: Table 2 presents the experimental results of all approaches on imputation and prediction tasks from MIMIC-III and eICU datasets. Together these results suggest that our approach achieves the best performance in both imputation and prediction tasks. For example, for the clinical time series imputation of MIMIC-III (24 hours after ICU admission), the MAE and MRE of Ours are 0.3563 and 8.16%, smaller than 0.3988 and 38.44% achieved by the best baseline (i.e., MTSIT). For the in-hospital mortality prediction of MIMIC-III (24 hours after ICU admission), the AUROC and AUPRC of Ours are 0.8533 and 0.4752, larger than 0.8461 and 0.4513 achieved by the best baseline (i.e., GRU-D).
2023MMUGL w/o \mathcal{C}(n) ablationAuPRC45.57horizon=30-day · variant=without extracted medical conceptsMulti-modal Graph Learning over UMLS Knowledge Graphs
Source quote
L349: \tableref{tab:concept-embedding-ablation} shows performance at a relevant 1 year horizon \citep{sparra-liley-medrxiv21}. At a 15-day horizon we outperform very recent results by GraphCare~\citep{graphcare-jiang-arxiv23} using language model enhanced knowledge graphs who report 69.0 AuROC on MIMIC-III, where we achieve average AuROC of 73.69 with MMUGL (and 71.93 with \emph{MMUGL w/o \mathcal{C}(n)}). MedGTX by~\citet{graph-text-park-chil22} is a large fusion architecture and at a 30-day horizon they report 41.9 AuPRC, we outperform this result with our efficient shared latent space and achieve 45.27 with MMUGL (and 45.57 with \emph{MMUGL w/o \mathcal{C}(n)}).
2023MedGTX baselineAuPRC41.9horizon=30-dayMulti-modal Graph Learning over UMLS Knowledge Graphs
Source quote
L349: \tableref{tab:concept-embedding-ablation} shows performance at a relevant 1 year horizon \citep{sparra-liley-medrxiv21}. At a 15-day horizon we outperform very recent results by GraphCare~\citep{graphcare-jiang-arxiv23} using language model enhanced knowledge graphs who report 69.0 AuROC on MIMIC-III, where we achieve average AuROC of 73.69 with MMUGL (and 71.93 with \emph{MMUGL w/o \mathcal{C}(n)}). MedGTX by~\citet{graph-text-park-chil22} is a large fusion architecture and at a 30-day horizon they report 41.9 AuPRC, we outperform this result with our efficient shared latent space and achieve 45.27 with MMUGL (and 45.57 with \emph{MMUGL w/o \mathcal{C}(n)}).
2023Chet baselinema-AUPRC.2328split: test · classes=135VecoCare: Visit Sequences-Clinical Notes Joint Learning for Diagnosis Prediction in Healthcare Data
Source quote
L424: .2328(.013)
2023Med2Vec backbone baselineAUPRC0.540split: test · backbone=Med2VecToward Cohort Intelligence: A Universal Cohort Representation Learning Framework for Electronic Health Record Analysis
Source quote
L356: Med2Vec~\cite{choi2016multi} │ 0.540 │ 57.4% │ 0.592 │ 0.325 │ 0.419
2022UniHPF (hi) proposedAUPRC0.327split: test · fine-tuned · time-gap=12-hour · input-duration=12-hour · prediction-window=48-hourUniHPF : Universal Healthcare Predictive Framework with Zero Domain Knowledge
Source quote
L516: \multirow{7}{*}{MIMIC-III} │ Mort │ \multicolumn{1}{c|}{0.327} │ \multicolumn{1}{c|}{0.325} │ \multicolumn{1}{c|}{0.290} │ \multicolumn{1}{c|}{0.291} │ 0.293
2022MedText proposedAUPRC0.63230-day unplanned ICU readmission prediction; clinical notes from patients’ EHRs.Predicting Patient Readmission Risk from Medical Text via Knowledge Graph Enhanced Multiview Graph Convolution
Source quote
L119: MedText │ 0.825 │ 0.632 │ 0.319
2022Wav2Vec (hierarchical) baselineAUPRC0.325split: test · fine-tuned · time-gap=12-hour · input-duration=12-hour · prediction-window=48-hourUniHPF : Universal Healthcare Predictive Framework with Zero Domain Knowledge
Source quote
L516: \multirow{7}{*}{MIMIC-III} │ Mort │ \multicolumn{1}{c|}{0.327} │ \multicolumn{1}{c|}{0.325} │ \multicolumn{1}{c|}{0.290} │ \multicolumn{1}{c|}{0.291} │ 0.293
2022CC-LSTM baselineAUPRC0.61330-day unplanned ICU readmission prediction; clinical notes from patients’ EHRs. The pa…Predicting Patient Readmission Risk from Medical Text via Knowledge Graph Enhanced Multiview Graph Convolution
Source quote
L118: CC-LSTM \cite{zhang2020learning} │ 0.804 │ 0.613 │ N/A
2020MusaNet proposed non-standard slicePR-AUC0.3261split: test · subset=DxSelf-attention Enhanced Patient Journey Understanding in Healthcare System
Source quote
L267: MusaNet │ 0.3261 │ 0.6507 │ 0.6069 │ 0.7104 │ 0.8227
2020MusaNet proposed non-standard slicePR-AUC0.3344split: test · subset=Dx & TxSelf-attention Enhanced Patient Journey Understanding in Healthcare System
Source quote
L276: MusaNet │ 0.3344 │ 0.6618 │ 0.6127 │ 0.7146 │ 0.8242
2020BRNN baseline non-standard slicePR-AUC0.3119split: test · subset=DxSelf-attention Enhanced Patient Journey Understanding in Healthcare System
Source quote
L261: BRNN │ 0.3119 │ 0.6362 │ 0.5925 │ 0.7014 │ 0.8128
2020BRNN baseline non-standard slicePR-AUC0.3270split: test · subset=Dx & TxSelf-attention Enhanced Patient Journey Understanding in Healthcare System
Source quote
L270: BRNN │ 0.3270 │ 0.6402 │ 0.5961 │ 0.7088 │ 0.8138
2019Notes-HCR proposedAUPRC0.3853split: val · window=W=48 · modality=clinical-notes · evaluation=5-fold cross-validationTowards unstructured mortality prediction with free-text clinical notes
Source quote
L111: \text{Notes-HCR} │ 0.8355^\dagger\sd{0.0096} │ 0.8675 (*)\sd{0.0083} │ 0.8887 (**)\sd{0.0060} │ 0.2753^\dagger\sd{0.0197} │ 0.3327 (*)\sd{0.0116} │ 0.3853 (**)\sd{0.0156} [-1pt]\multicolumn{8}{l}{Multi-modal} \\[-7pt]
2019MM-HCR proposedAUPRC0.4332split: val · window=W=48 · modality=clinical-notes-and-time-series · evaluation=5-fold cross-validationTowards unstructured mortality prediction with free-text clinical notes
Source quote
L112: \text{MM-HCR} │ 0.8463^\dagger\sd{0.0107} │ 0.8787 (*)\sd{0.0061} │ 0.9023\sd{0.0043} │ 0.2985^\dagger\sd{0.0256} │ 0.3583 (*)\sd{0.0207} │ 0.4332\sd{0.0125}
2019Full Model (proposed hierarchical representation model) proposedAUPRC0.7476Full Model row in the attention-mechanism ablation table; death prediction task.Learning Hierarchical Representations of Electronic Health Records for Clinical Outcome Prediction
Source quote
L336: Full Model │ 0.9428 │ 0.7476 │ 0.9016 │ 0.8424
2019Full Model (proposed hierarchical representation model) proposedAUPRC0.8424Full Model row in the attention-mechanism ablation table; ICU admission prediction task.Learning Hierarchical Representations of Electronic Health Records for Clinical Outcome Prediction
Source quote
L336: Full Model │ 0.9428 │ 0.7476 │ 0.9016 │ 0.8424
2019G-BERT proposedPR-AUC0.6960split: test · subset=patients with more than one visitPre-training of Graph Augmented Transformers for Medication Recommendation
Source quote
L275: \texttt{G-BERT}\xspace │ \bf 0.4565 │ \bf 0.6960 │ \bf 0.6152 │ 3,034,045
2019CTS-RNN baselineAUPRC0.3475split: val · window=W=48 · modality=clinical-time-series · evaluation=5-fold cross-validationTowards unstructured mortality prediction with free-text clinical notes
Source quote
L109: \text{CTS-RNN} │ 0.8090\sd{0.0092} │ 0.8425\sd{0.0099} │ 0.8765 (**)\sd{0.0065} │ 0.2342\sd{0.0250} │ 0.3010\sd{0.0168} │ 0.3475 (**)\sd{0.0178}
2019GAMENet baselinePR-AUC0.6854split: test · subset=patients with more than one visit · variant=with DDI knowledge and procedure codesPre-training of Graph Augmented Transformers for Medication Recommendation
Source quote
L271: GAMENet │ 0.4555 │ 0.6854 │ 0.6126 │ 5,518,646
2017SAnD proposedAUPRC0.316split: testAttend and Diagnose: Clinical Time Series Analysis Using Attention Models
Source quote
L172: AUPRC │ 0.2132 │ 0.298 │ 0.316 │ 0.319 │ 0.327
2017LSTM baselineAUPRC0.298split: testAttend and Diagnose: Clinical Time Series Analysis Using Attention Models
Source quote
L172: AUPRC │ 0.2132 │ 0.298 │ 0.316 │ 0.319 │ 0.327