MHIST
7 papers · 14 extracted observations · image classification · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Proposed/measured results matching task=Image Classification, split=test, regime=linear-probe.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | PolarHE (75% common-feature ratio) SOTA frontier | 89.06% | 2025-03-01 | pretraining=polarization-guided · inference-input=H&E · common-feature-ratio=75% · Test performance using linear probing on the frozen encoder; averaged over three rand… | Beyond H&E: Unlocking Pathological Insights with Polarization via Self-supervised LearningSource quotePolarHE (ours) │ 89.06 │ 88.97 │ 94.10 |
| 2 | basicBT SOTA frontier | 84.95% | 2024-11-01 | variant=pkgh-600 · pretraining-cohort=KGH · Linear evaluation on the original MHIST train/test split using a frozen encoder pretr… | Efficient Self-Supervised Barlow Twins from Limited Tissue Slide Cohorts for Colonic Pathology DiagnosticsSource quotebasicBT │ 82.5 - 0.8061 │ 83.32 - 0.8194 │ 84.95 - 0.7971 |
| 3 | DINOv2 with Extended-Context Translation (ECT), CSD position encoding, and KDE regularization SOTA frontier | 81.78% | 2024-05-01 | backbone=DINOv2 · magnification=5× · position-encoding=CSD · Tile-level benign-versus-precursor classification on the 5× MHIST dataset; linear pro… | Adapting Self-Supervised Learning for Computational PathologySource quoteMHIST │ \multicolumn{1}{c|}{79.12} │ \multicolumn{1}{c|}{77.58} │ \multicolumn{1}{c|}{76.56} │ \multicolumn{1}{c|}{80.25} │ \multicolumn{1}{c|}{75.33} │ \multicolumn{1}{c|}{80.55} │ \multicolumn{1}{c|}{72.88} │ 81.78 |
Metricaccuracy (7)auc (3)total label information bits sample upper bound (2)training time to convergence (1)f1 (1)
Splittest (9)
Showing 9 of 9 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | PolarHE (75% common-feature ratio) proposed | Accuracy (Acc) | 89.06% | Image Classification · split: test · linear-probe · pretraining=polarization-guided · inference-input=H&E · common-feature-ratio=75% | Beyond H&E: Unlocking Pathological Insights with Polarization via Self-supervised LearningSource quoteL236: PolarHE (ours) │ 89.06 │ 88.97 │ 94.10 |
| 2025 | PolarHE (75% common-feature ratio) proposed | F1 score (F1) | 88.97% | Image Classification · split: test · linear-probe · pretraining=polarization-guided · inference-input=H&E · common-feature-ratio=75% | Beyond H&E: Unlocking Pathological Insights with Polarization via Self-supervised LearningSource quoteL236: PolarHE (ours) │ 89.06 │ 88.97 │ 94.10 |
| 2025 | PolarHE (75% common-feature ratio) proposed | AUC | 94.10% | Image Classification · split: test · linear-probe · pretraining=polarization-guided · inference-input=H&E · common-feature-ratio=75% | Beyond H&E: Unlocking Pathological Insights with Polarization via Self-supervised LearningSource quoteL236: PolarHE (ours) │ 89.06 │ 88.97 │ 94.10 |
| 2024 | DINOv2 with Extended-Context Translation (ECT), CSD position encoding, and KDE regularization proposed | Test accuracy | 81.78 | Image Classification · split: test · linear-probe · backbone=DINOv2 · magnification=5× · position-encoding=CSD | Adapting Self-Supervised Learning for Computational PathologySource quoteL122: MHIST │ \multicolumn{1}{c|}{79.12} │ \multicolumn{1}{c|}{77.58} │ \multicolumn{1}{c|}{76.56} │ \multicolumn{1}{c|}{80.25} │ \multicolumn{1}{c|}{75.33} │ \multicolumn{1}{c|}{80.55} │ \multicolumn{1}{c|}{72.88} │ 81.78 |
| 2024 | basicBT proposed | Accuracy | 84.95 | Image Classification · split: test · linear-probe · variant=pkgh-600 · pretraining-cohort=KGH | Efficient Self-Supervised Barlow Twins from Limited Tissue Slide Cohorts for Colonic Pathology DiagnosticsSource quoteL241: basicBT │ 82.5 - 0.8061 │ 83.32 - 0.8194 │ 84.95 - 0.7971 |
| 2024 | imBT proposed | AUC | 0.8264 | Image Classification · split: test · linear-probe · variant=pkgh-800 · pretraining-cohort=KGH | Efficient Self-Supervised Barlow Twins from Limited Tissue Slide Cohorts for Colonic Pathology DiagnosticsSource quoteL242: imBT │ 82.5 - 0.8033 │ 82.6 - 0.8264 │ 82.5 - 0.8217 |
| 2024 | benchBT baseline | Accuracy | 80.76 | Image Classification · split: test · linear-probe · variant=benchmark-weight · training-cohort-size=36k WSIs | Efficient Self-Supervised Barlow Twins from Limited Tissue Slide Cohorts for Colonic Pathology DiagnosticsSource quoteL236: MHIST. MHIST dataset is designed to classify colorectal polyps into two histological categories: Hyperplastic Polyps and Sessile Serrated Adenomas. It comprises 3,152 patches which are H\ │ E stained, and it was chosen because of the similarity of these two classes to those of our KGH dataset. The original split train/test is used to train and evaluate the linear layer. Table \ref{tab_mhist} presents the accuracy and AUC of the diverse models pretrained on three different FoV of the KGH dataset using four different methods presented in Table \ref{tab_all_models}. Additionally, the linear evaluation of benchBT on MHIST provides an accuracy of 80.76 and an AUC of 0.7943. For MHIST dataset, basicBT and imBT outperform the benchmark weights and the two proposed methods. If basicBT provides the best accuracy (for the model pre-trained on pkgh-600), imBT provides the best AUC (for the model pre-trained on pkgh-800). If the accuracy for imBT remains constant throughout the three datasets, it seems the representations given by basicBT, pathBT and swinBT are highly dependent on the pretraining dataset. These results show that our proposed methods do not generalize well to this downstream task. However, the default transformations generalize better. The weak colour jitter could be a reason for this lack of generalizability, as the model will have a lower ability to generalize to other stains. These results also highlight the potential of the KGH dataset to be used as a pretraining dataset for diverse downstream tasks, as imBT and basicBT outperform the benchmark model, trained on a massive cohort of data (36k WSIs). |
| 2023 | DiRL-T proposed | Acc | 0.782 | Image Classification · split: test · fine-tuned · validation=5-fold cross-validation · pretraining=BRCA | Attention De-sparsification Matters: Inducing diversity in digital pathology representation learningSource quoteL259: DiRL-T │ \multicolumn{1}{c}{0.782, 0.871} │ \multicolumn{1}{c}{0.828, 0.945} |
| 2023 | DiRL-T proposed | AUC | 0.871 | Image Classification · split: test · fine-tuned · validation=5-fold cross-validation · pretraining=BRCA | Attention De-sparsification Matters: Inducing diversity in digital pathology representation learningSource quoteL259: DiRL-T │ \multicolumn{1}{c}{0.782, 0.871} │ \multicolumn{1}{c}{0.828, 0.945} |