MedQA
107 papers · 217 extracted observations · question answering · language · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | KnowGPT SOTA frontier | 78.1% | 2024-01-01 | llm-tuning=none · Supplementary comparison with fine-tuned LLMs; the paper says KnowGPT uses no LLM tun… | KnowGPT: Knowledge Graph based Prompting for Large Language ModelsSource quote\texttt{KnowGPT} │ 81.8% │ 92.4% │ 78.1% |
| 2 | LLaMA 3.1-8B (trained) + GroupRAG (+2 variants) | 71.75% | 2026-03-01 | params=8B · Separate 400-question information-dense test set. The trained small-language-model va… | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 3 | MedGENIE-FID-Flan-T5 | 53.1% | 2024-01-01 | reader=Fusion-in-Decoder · backbone=Flan-T5 · Fine-tuned Fusion-In-Decoder reader grounded on PMC-LLaMA-generated contexts; supervi… | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteMedGENIE-FID-Flan-T5 │ G (PMC-LLaMA) │ Fine-tuned │ 250M │ 53.1 |
| 4 | Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned) | 20.59% | 2025-06-01 | params=8B · pruning=67% · backbone=LLaMA 3 8B · LightEval medical-QA evaluation; fine-tuned (FT) variant. | Enabling On-Device Medical AI Assistants via Input-Driven Saliency AdaptationSource quoteLLaMA\,3\,8B │ 67% Pruned (FT) │ 5.58 │ 29.45% │ 20.59% │ 43.15% |
Showing 98 of 98 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | SACC proposed | L | .635 | split: val | Residual Attribute Leakage Is an Interface: Auditing Privacy Evaluation After Text De-identificationSource quoteL926: .635 |
| 2026 | FV-8B proposed | Accuracy | 86.2% | split: test · params=8B | Fathom-Vaidya: Advancing Medical Reasoning with Rubric-Based RewardsSource quoteL667: 86.2 (+6.4%) |
| 2026 | Qwen3-4B L1-Low proposed | g-mean2 (monitorability) | 0.62 | rl-fine-tuned · params=4B | Efficient Reasoning Training Does Not Always Harm CoT Faithfulness and MonitorabilitySource quoteL590: than 0.2 on all three models. Figure 6 shows g-mean2 dropping from 0.87 to 0.62 on Qwen3-4B |
| 2026 | SelectKV-90 (SKV-90) proposed | Accuracy | 62.0% | params=4B | Selective and Hybrid-State Communication for Latent Multi-Agent SystemsSource quoteL405: 62.0 |
| 2026 | HyLaMAS (Qwen3.5-4B) proposed | Accuracy | 77.0% | params=4B | Selective and Hybrid-State Communication for Latent Multi-Agent SystemsSource quoteL577: 77.0 |
| 2026 | HyLaMAS (Qwen3.5-9B) proposed | Accuracy | 88.0% | params=9B | Selective and Hybrid-State Communication for Latent Multi-Agent SystemsSource quoteL581: 88.0 |
| 2026 | SafeReAct proposed | domain utility score | 74% | params=8B · backbone=Llama-3-8B-UltraMedical | Finding and Reactivating Post-Trained LLMs' Hidden Safety MechanismsSource quoteL298: SafeReAct │ 6% │ 74% |
| 2026 | HSIR-SFT (All) proposed | Accuracy | 45.33 | split: test · 0-shot · params=1.5B · backbone=Qwen2.5-1.5B · iterations=1 | Better, Faster: Harnessing Self-Improvement in Large Reasoning ModelsSource quoteL220: ReST (EM) │ 41.63 │ 1,424 │ 69.75 │ 1,382 \textbf{\texttt{HSIR-SFT} (All)} │ \bf 45.33 │ \bf 1,064 │ \bf 71.72 │ \bf 1,181 |
| 2026 | HSIR-SFT (All) proposed | Tokens | 1,064 tokens | split: test · 0-shot · params=1.5B · backbone=Qwen2.5-1.5B · iterations=1 | Better, Faster: Harnessing Self-Improvement in Large Reasoning ModelsSource quoteL220: ReST (EM) │ 41.63 │ 1,424 │ 69.75 │ 1,382 \textbf{\texttt{HSIR-SFT} (All)} │ \bf 45.33 │ \bf 1,064 │ \bf 71.72 │ \bf 1,181 |
| 2026 | InfoGatherer (gpt-5-nano) proposed | success rate | 69.3% | backbone=gpt-5-nano | InfoGatherer: Principled Information Seeking via Evidence Retrieval and Strategic QuestioningSource quoteL208: In the legal domain, \textcolor{black}{InfoGatherer}\xspace{} with \texttt{gpt-5-nano} attains 66.5% success. This is a large improvement over AoP (17.1%) and MediQ (27.2%), corresponding to gains of 49.4 and 39.3 points. \textcolor{black}{InfoGatherer}\xspace{} also outperforms UoT by 33.7 points (66.5% vs. 32.8%). UoT uses fewer turns (4.9 vs. 5.9), but its substantially lower success rate suggests that optimizing primarily for short dialogues can leave decisive facts unelicited. With \texttt{Qwen3 32B}, we observe the same pattern. \textcolor{black}{InfoGatherer}\xspace{} achieves 64.3% success in 5.4 turns, remaining more accurate than UoT (60.8%) at a comparable dialogue length (5.4 vs. 5.1). In the medical domain, \textcolor{black}{InfoGatherer}\xspace{} again improves both correctness and efficiency relative to the interactive baselines. With \texttt{gpt-5-nano}, \textcolor{black}{InfoGatherer}\xspace{} reaches 69.3% success and the shortest dialogues (7.4 turns), outperforming AoP (41.6%) and MediQ (59.1%). It also improves over UoT (63.8%) while using slightly fewer turns on average (7.4 vs.\ 7.6). With \texttt{Qwen3 32B}, \textcolor{black}{InfoGatherer}\xspace{} achieves 68.1% success with 7.1 turns, which is a substantial gain over AoP (39.2%) and MediQ (56.4%). |
| 2026 | InfoGatherer (Qwen3 32B) proposed | success rate | 68.1% | params=32B · backbone=Qwen3 32B | InfoGatherer: Principled Information Seeking via Evidence Retrieval and Strategic QuestioningSource quoteL208: In the legal domain, \textcolor{black}{InfoGatherer}\xspace{} with \texttt{gpt-5-nano} attains 66.5% success. This is a large improvement over AoP (17.1%) and MediQ (27.2%), corresponding to gains of 49.4 and 39.3 points. \textcolor{black}{InfoGatherer}\xspace{} also outperforms UoT by 33.7 points (66.5% vs. 32.8%). UoT uses fewer turns (4.9 vs. 5.9), but its substantially lower success rate suggests that optimizing primarily for short dialogues can leave decisive facts unelicited. With \texttt{Qwen3 32B}, we observe the same pattern. \textcolor{black}{InfoGatherer}\xspace{} achieves 64.3% success in 5.4 turns, remaining more accurate than UoT (60.8%) at a comparable dialogue length (5.4 vs. 5.1). In the medical domain, \textcolor{black}{InfoGatherer}\xspace{} again improves both correctness and efficiency relative to the interactive baselines. With \texttt{gpt-5-nano}, \textcolor{black}{InfoGatherer}\xspace{} reaches 69.3% success and the shortest dialogues (7.4 turns), outperforming AoP (41.6%) and MediQ (59.1%). It also improves over UoT (63.8%) while using slightly fewer turns on average (7.4 vs.\ 7.6). With \texttt{Qwen3 32B}, \textcolor{black}{InfoGatherer}\xspace{} achieves 68.1% success with 7.1 turns, which is a substantial gain over AoP (39.2%) and MediQ (56.4%). |
| 2026 | User-centric audit framework (linguistic and locale convention audit) proposed | American-centered share, excluding spelling | 44.3% | Share of matched non-spelling convention signals that are American-centered. | Whose Data, Whose Benchmark? A User-Centric Framework for Auditing Evaluation ResourcesSource quoteL425: 44.3 |
| 2026 | LLM with E1 few-shot prompt intervention based on nonspecific systemic symptoms proposed | benchmark accuracy | 84.3% | few-shot · subset=analyzed cases | VeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge GraphsSource quoteL657: Under this limited prompt modification, the eight previously incorrect cases associated with this error pattern were corrected, and the benchmark accuracy on the analyzed cases increased from 81.5% to 84.3%. |
| 2026 | LLM with E2 few-shot prompt intervention based on pruritus or similar dermatologic symptoms proposed | benchmark accuracy | 85.5% | few-shot · subset=analyzed set | VeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge GraphsSource quoteL685: Under this limited intervention, the previously incorrect cases matching this pattern were corrected, and the benchmark accuracy in this run increased from 81.5% to 85.5% on the analyzed set. |
| 2026 | LLaMA 3.1-8B (trained) + GroupRAG proposed | Answer accuracy | 71.75% | split: test · fine-tuned · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL239: L3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 2026 | LLaMA 3.1-8B (base) + GroupRAG proposed | Answer accuracy | 61.00% | split: test · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL238: L3.1-8B(base) │ 48.25 │ 54.50 │ 53.50 │ 61.00 |
| 2026 | Ens(DKPS+IRT) proposed non-standard slice | Mean absolute error (MAE) | 0.117 | evaluation=leave-one-family-out · query-budget=1 | Query-efficient model evaluation using cached responsesSource quoteL46: Ens(DKPS+IRT) │ 0.089 │ 0.070 │ 0.050 │ 0.031 │ 0.117 │ 0.096 │ 0.061 │ 0.032 │ 0.039 │ 0.027 │ 0.018 │ 0.013 │ 0.145 │ 0.098 │ 0.068 │ 0.042 |
| 2026 | HCQR proposed | answer accuracy | 75.0 | final-context-budget=15 documents · model-configurations=average across 4 | Hypothesis-Conditioned Query Rewriting for Decision-Useful RetrievalSource quoteL408: HCQR (ours) │ 63.4 │ 73.0 │ 77.9 │ 85.8 │ 75.0 │ 68.6 │ 79.7 │ 85.4 │ 90.6 │ 81.1 |
| 2026 | HCQR proposed | Decision-Useful Rate (DUR; Entailed + Useful) | 82.1% | final-context-budget=15 documents · model-configurations=average across 4 | Hypothesis-Conditioned Query Rewriting for Decision-Useful RetrievalSource quoteL444: HCQR (ours) │ 73.4 │ 81.8 │ 83.2 │ 89.8 │ 82.1 │ 65.8 │ 69.1 │ 72.5 │ 73.7 │ 70.3 |
| 2026 | HARISSA (device setting; no deferral) proposed | wrong answers delivered | 14.3 % of queries | No deferral; device setting, on HARISSA's delivered answers at its selected thresholds. | HARISSA: Inference-Time Self-Checks for Efficient and Safe Local Language Model DeploymentSource quoteL501: MedQA │ 8.7% │ 14.3 │ 9.7 |
| 2026 | HARISSA answer-probability deferral (device setting) proposed | wrong answers delivered | 9.7 % of queries | Answer-probability deferral at the selected fall-through threshold; 8.7% of queries def… | HARISSA: Inference-Time Self-Checks for Efficient and Safe Local Language Model DeploymentSource quoteL501: MedQA │ 8.7% │ 14.3 │ 9.7 |
| 2026 | CARE proposed | Valid Causal Reasoning | 86.2% | split: test · subset=500 queries answered correctly by both Standard GRPO and CARE · evaluation=three-expert panel, majority vote | CARE: Causally-Aligned Reasoning Exploration for Medical Large Language ModelsSource quoteL382: To empirically validate that CARE mitigates the ``Right Answer, Wrong Reason'' trap, we conducted a clinical consistency evaluation. We randomly sampled 500 queries from the MedQA test set where both Standard GRPO and CARE predicted the correct final answer. The generated rationales were then evaluated by a panel of three human experts through majority voting, classifying them into: (1) Valid Causal Reasoning, (2) Spurious Shortcut (correct answer but logically insufficient or relying on statistical priors), and (3) Unrelated Hallucination. As shown in Figure \ref{fig:shortcut}(Left), although Standard GRPO yields correct outcomes on these samples, 45.0% of its rationales rely on spurious correlations. In contrast, CARE increases the proportion of Valid Causal Reasoning to 86.2%. This corroborates Theorem \ref{thm:debiasing}, demonstrating that our self-verification mechanism successfully severs the model's reliance on dataset artifacts in favor of causally-aligned deduction. |
| 2026 | PRA (trained reward agent; search enabled) proposed | Acc. | 80.8 | params=4B | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL244: PRA (ours) │ \checkmark │ \checkmark │ PRA │ 64(B × b) │ 80.8 |
| 2026 | EDCO proposed | Accuracy | 36.7% | params=3B | EDCO: Dynamic Curriculum Orchestration for Domain-specific Large Language Model Fine-tuningSource quoteL192: MedQA │ 32.1 │ 32.9 │ 35.1 │ 32.4 │ 24.6 │ 36.7 |
| 2026 | PolicyAlign (Qwen2.5-7B-Instruct) proposed | Accuracy | 0.5727 | params=7B · backbone=Qwen2.5-7B-Instruct | PolicyAlign: Direct Policy-Based Safety Alignment for Large Language ModelsSource quoteL308: Medical safety. Figure~\ref{fig:medical_results} shows that PolicyAlign improves medical safety while largely preserving medical capability. On MedSafetyBench, PolicyAlign reduces the Harmfulness Score from 1.753 to 1.100. Moreover, PolicyAlign achieves the best results on CARES across all three metrics. These results suggest that PolicyAlign improves safety beyond simple refusal behavior, extending to more nuanced medical safety classification and response generation. Meanwhile, PolicyAlign preserves medical capability much better than SFT. For example, on MedQA, SFT drops to 0.4595, whereas PolicyAlign reaches 0.5727, close to the base model's 0.5892. |
| 2026 | QIME-TF-MMR proposed | nDCG@10 | 62.36 | top-k=256 · lambda=0.7 · variant=training-free MMR · ontology-grounding=MedG | Asking the Right Questions: Ontology-Grounded Interpretable Embeddings for Biomedical TextSource quoteL306: \ding{51} │ 25.09 │ 75.64 │ 62.36 │ 64.65 │ 11.79 │ 7.08 │ 41.10 |
| 2026 | AlignBeam on MedLlama-3-8B proposed | accuracy | 12.7% | params=8B | ALIGNBEAM: Inference-Time Alignment Transfer via Cross-Vocabulary Logit MixingSource quoteL1674: from 13.1% to 12.7% (-0.4\,pp). Full per-strategy |
| 2026 | AgenticRag-R1 proposed | Format Acc | 92% | split: test · judge=Qwen2.5-72B · params=7B · backbone=Qwen2.5-7B-Instruct | AgenticRag-R1: Agentic Reinforcement Learning with Stack Memory for Multi-Step Reasoning, Retrieval and MemorizingSource quoteL1460: AgenticRag-R1 │ 92% │ 87% |
| 2026 | AgenticRag-R1 proposed | Answer Acc | 87% | split: test · judge=Qwen2.5-72B · params=7B · backbone=Qwen2.5-7B-Instruct | AgenticRag-R1: Agentic Reinforcement Learning with Stack Memory for Multi-Step Reasoning, Retrieval and MemorizingSource quoteL1460: AgenticRag-R1 │ 92% │ 87% |
| 2026 | ATPO (U1+U2) proposed | accuracy gain over TreePO | 0.82% | params=1.7B · backbone=Qwen3-1.7B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | ATPO (U1+U2) proposed | accuracy gain over TreePO | 1.73% | params=4B · backbone=Qwen3-4B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | ATPO (U1+U2) proposed | accuracy gain over TreePO | 2.26% | params=8B · backbone=Qwen3-8B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | ATPO proposed | accuracy difference | 0.92% | params=8B · backbone=Qwen3-8B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | SGR-LLaMA-3.3-70B proposed | accuracy | 79.81 | params=70B · backbone=LLaMA-3.3-70B | From Chains to Graphs: Self-Structured Reasoning for General-Domain LLMsSource quoteL279: SGR-LLaMA-3.3-70B │ 69.91 │ 57.50 │ 79.81 |
| 2026 | BELIEF (Qwen2.5-7B) proposed | ACC | 0.660 | split: test · 0-shot · params=7B · backbone=Qwen2.5-7B · retrieval=top-5 PubMed · sample-size=500 | BELIEF: Structured Evidence Modeling and Uncertainty-Aware Fusion for Biomedical Question AnsweringSource quoteL472: BELIEF │ 0.632 │ 0.447 │ 0.660 │ 0.645 │ 0.622 │ 0.612 |
| 2026 | AgentFactory (Ours; GPT-4o-mini foundation-model setting) proposed | performance | 86.8 | params=8B · backbone=Llama-3.1-8B-Instruct · repetitions=3 · foundation-model=GPT-4o-mini · additional-models=Llama-3.1-8B-Instruct; GPT-4o-mini | AgentFactory: Towards Automated Agentic System Design and OptimizationSource quoteL237: 86.8 |
| 2026 | GPT-3 (k-NN) proposed | F1@3 | 15.08 | few-shot · k=5 · retrieval=k-NN · similarity=cosine · embedding-model=MPNet | Beyond Fine-Tuning: In-Context Learning and Chain-of-Thought for Reasoned Distractor GenerationSource quoteL282: ICL also outperforms Text2Text models. While the contrastive-based model provides steady improvements over base fine-tuning and multi-task learning in all datasets and still achieves the highest F1@3 score on SciQ, it remains less competitive with longer distractor tokens and diverse domains, such as the medical field. In fact, ICL shows consistently stronger performance than recent SOTA contrastive-based models in the DG task. Its F1@3 score rises from 15.70 to 19.69 on MCQ and 13.67 to 24.44 on MCQL, with even larger improvements on datasets with longer distractor lengths: 10.39 to 18.10 on ARC-Easy, 5.47 to 15.29 on ARC-Challenge, and 3.50 to 15.08 on MedQA. |
| 2026 | StackSL (Full) proposed | Acc | 0.5962 | split: test · fine-tuned · params=4B · backbone=Qwen3-4B-Base · reference-model=Qwen3-4B | Optimal Budgeted Adaptation of Large Language ModelsSource quoteL640: 0.5962 │ 0.5922 │ 0.0045 |
| 2025 | KRAL proposed non-standard slice | Accuracy@1 | +1.8% | fine-tuned · subset=English-language antimicrobial-focused (n=56) | KRAL: Knowledge and Reasoning Augmented Learning for LLM-assisted Clinical Antimicrobial TherapySource quoteL276: Evaluation results demonstrate that the KRAL method achieves a +1.8% accuracy improvement over SFT and a +3.6% improvement over RAG with statistical significance mark '*' in Figure 7. This validates that the KRAL method can effectively achieve knowledge augmentation even on external test sets. |
| 2025 | KRAL proposed non-standard slice | Accuracy@1 | +3.6% | subset=English-language antimicrobial-focused (n=56) | KRAL: Knowledge and Reasoning Augmented Learning for LLM-assisted Clinical Antimicrobial TherapySource quoteL276: Evaluation results demonstrate that the KRAL method achieves a +1.8% accuracy improvement over SFT and a +3.6% improvement over RAG with statistical significance mark '*' in Figure 7. This validates that the KRAL method can effectively achieve knowledge augmentation even on external test sets. |
| 2025 | PANGEA (ours), Llama3.2-1B proposed | Accuracy | 44.62% | 0-shot · params=1B | PANGEA: Projection-Based Augmentation with Non-Relevant General Data for Enhanced Domain Adaptation in LLMsSource quoteL286: 44.62 |
| 2025 | Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned) proposed | Accuracy | 20.59% | fine-tuned · params=8B · pruning=67% · backbone=LLaMA 3 8B | Enabling On-Device Medical AI Assistants via Input-Driven Saliency AdaptationSource quoteL170: LLaMA\,3\,8B │ 67% Pruned (FT) │ 5.58 │ 29.45% │ 20.59% │ 43.15% |
| 2025 | RASD(REST) proposed | SR (speedup ratio) | 2.57 | params=14B · backbone=Qwen2.5-14B · retrieval=REST · temperature=0 | RASD: Retrieval-Augmented Speculative DecodingSource quoteL458: 2.57 |
| 2025 | AutoMedPrompt with Llama 3 (70B) proposed non-standard slice | accuracy | 77.7% | split: test · params=70B | AutoMedPrompt: A New Framework for Optimizing LLM Medical Prompts Using Textual GradientsSource quoteL4: Large language models (LLMs) have demonstrated increasingly sophisticated performance in medical and other fields of knowledge. Traditional methods of creating specialist LLMs require extensive fine-tuning and training of models on large datasets. Recently, prompt engineering, instead of fine-tuning, has shown potential to boost the performance of general foundation models. However, prompting methods such as chain-of-thought (CoT) may not be suitable for all subspecialty, and k-shot approaches may introduce irrelevant tokens into the context space. We present AutoMedPrompt, which explores the use of textual gradients to elicit medically relevant reasoning through system prompt optimization. AutoMedPrompt leverages TextGrad's automatic differentiation via text to improve the ability of general foundation LLMs. We evaluated AutoMedPrompt on Llama 3, an open-source LLM, using several QA benchmarks, including MedQA, PubMedQA, and the nephrology subspecialty-specific NephSAP. Our results show that prompting with textual gradients outperforms previous methods on open-source LLMs and surpasses proprietary models such as GPT-4, Claude 3 Opus, and Med-PaLM 2. AutoMedPrompt sets a new state-of-the-art (SOTA) performance on PubMedQA with an accuracy of 82.6%, while also outperforming previous prompting strategies on open-sourced models for MedQA (77.7%) and NephSAP (63.8%). |
| 2025 | sudoLLM BFT (GPT-4o; fine-tuned on BQ) proposed | Alignment accuracy (Bob: unsafe queries refused) | 100% | 3-shot · epochs=1 · backbone=GPT-4o | sudoLLM: On Multi-role Alignment of Language ModelsSource quoteL238: 100 |
| 2025 | sudoLLM BFT (GPT-4o; fine-tuned on BQ) proposed | Alignment accuracy (Alice: queries answered) | 94.6% | 3-shot · epochs=1 · backbone=GPT-4o | sudoLLM: On Multi-role Alignment of Language ModelsSource quoteL241: 94.6 |
| 2025 | MedGemma 4B proposed | Accuracy | 64.4 | split: test · params=4B | MedGemma Technical ReportSource quoteL217: MedGemma 4B │ \checkmark │ 64.4 │ 55.7 │ 73.4 │ 59.3 │ 71.3 │ 70.8 │ 65.3 │ 83.0 │ 76.8 │ 53.0 │ 52.0 |
| 2025 | MedAgentSim (LLaMA 3.3) proposed | benchmark performance score | 70.8% | backbone=LLaMA 3.3 | MedAgentSim: Self-evolving Multi-agent Simulations for Realistic Clinical InteractionsSource quoteL119: For language-based reasoning, MedAgentSim consistently demonstrates superior performance. In MedQA, it achieves 70.8% with LLaMA 3.3, while the best-performing baseline model records 62.3%. Similarly, in MedQA Extended, |
| 2025 | KAMAC proposed | Acc | 88.14 | MedQA comparison table; split and averaging are not specified in the cited lines. | A Knowledge-driven Adaptive Collaboration of LLMs for Enhancing Medical Decision-makingSource quoteL266: KAMAC │ 88.14 │ 88.30 │ 97.02 │ 88.11 │ 90.39 │ 1.28 │ 10.80 │ 2.55 │ 5.01 |
| 2025 | Instruction retrieval proposed | accuracy | 9.4% | 0-shot · params=3B–14B | Big Reasoning with Small Models: Instruction Retrieval at Inference TimeSource quoteL4: Can we bring big-scale reasoning to local-scale compute? Small language models (SLMs) are increasingly attractive for deployment because they run efficiently on local hardware, offering strong privacy, reduced cost, and lower environmental impact. Yet these models consistently struggle on tasks that require multi-step reasoning or specialized domain knowledge. To address this gap, we introduce instruction intervention at inference time. Our method builds an Instruction Corpus by grouping similar training questions and creating instructions that pair background knowledge with step-by-step procedures. At inference, the model retrieves the most relevant instructions and follows the steps. Unlike standard retrieval-augmented generation, which supplies raw passages, our approach provides structured scaffolds that guide reasoning. We evaluate this framework on MedQA (medical board exams), MMLU Professional Law, and MathQA using models from 3B to 14B parameters without any additional fine-tuning. Instruction retrieval yields consistent gains: 9.4% on MedQA, 7.9% on MMLU Law, and 5.1% on MathQA. Concise instructions outperform longer ones, and the magnitude of improvement depends strongly on model family and intrinsic reasoning ability. |
| 2025 | High School Concise instructions with a 9B model (family not specified) proposed | accuracy | +18pp | 0-shot · params=9B · instruction-variant=High School Concise | Big Reasoning with Small Models: Instruction Retrieval at Inference TimeSource quoteL89: Figure~\ref {fig:hs-concise-performance} shows the accuracy of the High School Concise instructions compared to zero-shot prompting across MathQA, MedQA, and MMLU Law. For the smallest models under 3B parameters, improvements are mixed and often negative. A few exceptions exist, such as Qwen-3 1.7B base, which gains +15pp on MedQA, but the same model shows negligible changes on MMLU and MathQA. This instability suggests that tiny models lack the intrinsic reasoning ability to reliably leverage retrieved scaffolds, which is in line with prior research \cite{li2025smallmodelsstrugglelearn}. At around 3B parameters, gains become consistently positive, even if modest. LLaMA-3 3B, for instance, improves by +1–5pp across benchmarks. This marks a capacity threshold: once a model is large enough to follow multi-step guidance, retrieved instructions shift from being noise to providing usable structure. Above this threshold, performance consistently improves. Models from 4B to 14B shows gains across all three tasks, with deltas typically in the +5–18pp range. The largest improvements appear in MedQA and MMLU Law, where domain-specific knowledge and reasoning may lack representation in the limited parameter space. For example, Gemma-2 9B improves by +14pp on MMLU Law and Mistral 7B by +16pp, while MedQA gains reach +18pp at 9B. In contrast, MathQA gains are more muted, though still positive, likely because mathematical reasoning is already well represented in pretraining data, leaving less headroom for improvement. Overall, retrieved instructions consistently boost accuracy once models exceed 3B parameters, with robust gains across both symbolic and domain-expert reasoning tasks. Notably, on MedQA and MMLU Law, the 14B parameter SLMs with retrieved instructions surpass the zero-shot accuracy of GPT-4o. |
| 2025 | AMG-RAG (8B) proposed | F1 score | 74.1% | fine-tuned · params=8B parameters · fine-tuning=none · backbone-size=8B | Agentic Medical Knowledge Graphs Enhance Medical Question Answering: Bridging the Gap Between LLMs and Evolving Medical KnowledgeSource quoteL13: Evaluations on the MEDQA and MEDMCQA benchmarks demonstrate the effectiveness of \gls{myrag}, achieving an F1 score of 74.1% on MEDQA and an accuracy of 66.34% on MEDMCQA—surpassing both comparable models and those 10 to 100 times larger. By dynamically linking new findings and complex medical concepts, \gls{myrag} not only boosts accuracy but also enhances interpretability for medical queries, which has a critical impact on delivering up-to-date, trustworthy medical insights (GitHub: \url{https://github.com/MrRezaeiUofT/AMG-RAG}). |
| 2025 | AMG-RAG (PubMed-MKG-8B) proposed | Accuracy | 73.92% | params=8B · backbone-size=8B · configuration=PubMed-MKG | Agentic Medical Knowledge Graphs Enhance Medical Question Answering: Bridging the Gap Between LLMs and Evolving Medical KnowledgeSource quoteL254: \gls{myrag} │ PubMed-MKG-8B │ 73.92 |
| 2025 | Differentially private data synthesis (ε=1024) proposed | task utility | 0.42 | fine-tuned · epsilon=1024 · differential-privacy=on | A False Sense of Privacy: Evaluating Textual Data Sanitization Beyond Surface-level Privacy LeakageSource quoteL378: The MedQA utility decreases from 0.61 to 0.42, dropping below the 0.44 no private data baseline; we discuss this counterintuitive result in Appendix~\ref{app:dp-design}. |
| 2025 | AEPO-L (Ours), LLaMA-3.1 8B w/ AEPO proposed | Answer accuracy | 68.5 | params=8B · backbone=LLaMA-3.1 8B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL219: AEPO-L (Ours) │ 8B │ {68.5} |
| 2025 | AEPO-Q (Ours), Qwen2.5 7B w/ AEPO proposed | Answer accuracy | 62.5 | params=7B · backbone=Qwen2.5 7B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL220: AEPO-Q (Ours) │ 7B │ {62.5} |
| 2025 | HuatuoGPT-O1-8B w/ AEPO proposed | Answer accuracy | 75.4 | fine-tuned · params=8B · backbone=HuatuoGPT-O1-8B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL286: w/ AEPO (Ours) │ 75.4 │ 63.9 |
| 2025 | KAG-Med-Thinker proposed | Accuracy | 85.28 | params=14B · backbone=DeepSeek-R1-Distill-Qwen-14B | KAG-Thinker: Interactive Thinking and Deep Reasoning in LLMs via Knowledge-Augmented GenerationSource quoteL422: KAG-Med-Thinker │ 85.28 |
| 2025 | LoRA-Leak non-referenced MIA (best) proposed | Best AUC | 0.689 | fine-tuned · epochs=3 · backbone=Llama-2 · reference=non-referenced · weight_decay=none | LoRA-Leak: Membership Inference Attacks Against LoRA Fine-tuned Language ModelsSource quoteL581: ~ │ \multicolumn{1}{c}{PPL@val} │ \multicolumn{1}{c}{GAP} │ \multicolumn{1}{c|}{Best AUC} │ \multicolumn{1}{c}{PPL@val} │ \multicolumn{1}{c}{GAP} │ \multicolumn{1}{c|}{Best AUC} │ \multicolumn{1}{c}{PPL@val} │ \multicolumn{1}{c}{GAP} │ \multicolumn{1}{c}{Best AUC} w/o │ 1.098 │ 0.059 │ 0.735\rightarrow0.765 │ 1.041 │ 0.007 │ 0.687\rightarrow0.721 │ 0.950 │ 0.021 │ 0.689\rightarrow0.775 10 (-4) │ 1.099 │ 0.060 │ 0.736\rightarrow0.764 │ 1.043 │ 0.008 │ 0.687\rightarrow0.722 │ 0.953 │ 0.023 │ 0.689\rightarrow0.778 |
| 2025 | LoRA-Leak pt-referenced MIA (best) proposed | Best AUC | 0.775 | fine-tuned · epochs=3 · backbone=Llama-2 · reference=pt-referenced · weight_decay=none | LoRA-Leak: Membership Inference Attacks Against LoRA Fine-tuned Language ModelsSource quoteL581: ~ │ \multicolumn{1}{c}{PPL@val} │ \multicolumn{1}{c}{GAP} │ \multicolumn{1}{c|}{Best AUC} │ \multicolumn{1}{c}{PPL@val} │ \multicolumn{1}{c}{GAP} │ \multicolumn{1}{c|}{Best AUC} │ \multicolumn{1}{c}{PPL@val} │ \multicolumn{1}{c}{GAP} │ \multicolumn{1}{c}{Best AUC} w/o │ 1.098 │ 0.059 │ 0.735\rightarrow0.765 │ 1.041 │ 0.007 │ 0.687\rightarrow0.721 │ 0.950 │ 0.021 │ 0.689\rightarrow0.775 10 (-4) │ 1.099 │ 0.060 │ 0.736\rightarrow0.764 │ 1.043 │ 0.008 │ 0.687\rightarrow0.722 │ 0.953 │ 0.023 │ 0.689\rightarrow0.778 |
| 2025 | Clinical-R1-3B (Cold Start + CRPO) proposed | Accuracy | 53.07% | method=Cold Start + CRPO · params=3B | Clinical-R1: Empowering Large Language Models for Faithful and Comprehensive Reasoning with Clinical Objective Relative Policy OptimizationSource quoteL196: \begin{tabular}[c]{@{}l@{}}w/ Cold Start + CRPO (Clinical-R1-3B) │ \bf 3.29 │ \bf 2.33 │ \bf 4.95 │ \bf 2.02 │ \bf 12.95 │ \bf5.76 │ \bf3.36 │ 0.76 │ \bf 53.07 |
| 2025 | MDTeamGPT proposed | Accuracy | 90.1% | base-model=GPT-4 Turbo · consultation-rounds=600 | MDTeamGPT: A Self-Evolving LLM-based Multi-Agent Framework for Multi-Disciplinary Team Medical ConsultationSource quoteL30: \item Experimental results demonstrate that the framework, utilizing 600 rounds of consultation experience, achieves accuracies of 90.1% on the MedQA dataset and 83.9% on the PubMedQA dataset. Cross-dataset tests further confirm that the knowledge bases retain generalizable reasoning skills, not just isolated consultation data. |
| 2025 | IdepRAG proposed | performance score | 94.5 | split: test · document-coverage=high | Enhancing LLM Generation with Knowledge Hypergraph for Evidence-Based MedicineSource quoteL220: IdepRAG │ 94.5 │ 95.0 |
| 2025 | Med-swallow-13b fine-tuned with the mix setting (J-Casemap and MedQA data) proposed | Accuracy | 37.0 | fine-tuned · model=Med-swallow-13b · params=13b · training-data=J-Casemap and MedQA | Causal Tree Extraction from Medical Case Reports: A Novel Task for Experts-like Text ComprehensionSource quoteL313: + mix │ 37.0 │ 34.1 │ 38.6 |
| 2025 | TAGS with GPT-4o proposed non-standard slice | accuracy | 31.8% | backbone=GPT-4o · parameter-updates=none | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL30: Extensive experiments across nine MedQA benchmarks validate the robustness and adaptability of TAGS under both non-fine-tuned and fine-tuned settings. Our method consistently outperforms strong prompting and agent-based baselines across multiple foundation models, including GPT-4o (18.0% to 31.8%), DeepSeek-R1 (27.2% to 44.0%), and Qwen-2.5-7B (14.1% to 23.9%). Notably, we show that even without retrieving semantically similar exemplars, TAGS maintains strong performance by exposing models to diverse reasoning patterns rather than specific answers. |
| 2025 | TAGS with DeepSeek-R1 proposed non-standard slice | accuracy | 44.0% | backbone=DeepSeek-R1 · parameter-updates=none | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL30: Extensive experiments across nine MedQA benchmarks validate the robustness and adaptability of TAGS under both non-fine-tuned and fine-tuned settings. Our method consistently outperforms strong prompting and agent-based baselines across multiple foundation models, including GPT-4o (18.0% to 31.8%), DeepSeek-R1 (27.2% to 44.0%), and Qwen-2.5-7B (14.1% to 23.9%). Notably, we show that even without retrieving semantically similar exemplars, TAGS maintains strong performance by exposing models to diverse reasoning patterns rather than specific answers. |
| 2025 | TAGS with Qwen2.5-7B proposed non-standard slice | average accuracy | 23.9% | 0-shot · params=7B · backbone=Qwen2.5-7B · parameter-updates=none | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL250: To further contextualize the performance of our TAGS framework, we evaluate its effectiveness when integrated with the Qwen2.5-7B base model and compare its performance against a series of prominent open-source and medically fine-tuned large language models across the same nine challenging MedQA datasets. The results of this comparison are presented in Table~\ref{tab:results_medllm}. As shown in the table, our TAGS framework substantially boosts the zero-shot question answering capability of the base Qwen2.5-7B model, improving its average accuracy from 14.1% to 23.9%. |
| 2025 | Hi-Merging (Echelon-AI/Med-Qwen2-7B + shtdbb/qwen2-7b-med) proposed | Numerical performance (metric unspecified) | 64.9011 | fine-tuned · params=7B | Training-free LLM Merging for Multi-task LearningSource quoteL506: Hi-Merging\xspace (Ours) │ 64.9011 │ 31.9421 │ 45.1714 │ 97.755 │ 92.1692 │ 21.0211 │ 26.3293 │ 40.9803 │ 28.7816 │ 31.6779 │ 19.8074 │ 11.2958 |
| 2025 | QAP (Flan-T5 (11B)) proposed | accuracy | 44.01 | params=11B · backbone=Flan-T5-11B · knowledge-graph=UMLS | Question-Aware Knowledge Graph Prompting for Enhancing Large Language ModelsSource quoteL267: {44.01} |
| 2025 | Llama3.1 models fine-tuned on English-majority data proposed | accuracy | 29.8 | fine-tuned | Bridging language barriers in healthcare: a study on Arabic LLMsSource quoteL185: Our results in Table~\ref{tab:combined-results} show that different ratio of Arabic-English data yield to different performance levels depending on the evaluation task. For PubMedQA, training with exclusively Arabic data produces the best accuracy (71.2). While for MedMCQA and MedQA, the models perform best with strong Arabic majority and English Majority, respectively (35.1 and 29.8). Surprisingly, for the MMLU datasets, which focuses on testing direct knowledge application, using only English data, achieves 42.4 compared to the 39.8 zero-shot accuracy. |
| 2024 | MedAgent-Zero proposed | Accuracy | 92.22 | backbone=GPT-4o · training-data=MedQA labeled training data not used | Agent Hospital: A Simulacrum of Hospital with Evolvable Medical AgentsSource quoteL292: MedAgent-Zero │ {\ul 74.31} │ {\ul 89.71} │ {\ul 92.22} │ 96.15 |
| 2024 | MedAgent-Zero (Hybrid) proposed | Accuracy | 92.77 | backbone=GPT-4o · training-data=MedQA training data added to medical case base | Agent Hospital: A Simulacrum of Hospital with Evolvable Medical AgentsSource quoteL293: MedAgent-Zero (Hybrid) │ 76.83 │ 91.20 │ 92.77 │ 96.15 |
| 2024 | MedGraphRAG (GPT-4) proposed | Accuracy | 91.3% | model=GPT-4 · retrieval=MedGraphRAG | Medical Graph RAG: Towards Safe Medical Large Language Model via Graph Retrieval-Augmented GenerationSource quoteL164: GPT-4 │ 86.5 │ 83.4 │ 91.3 │ 81.5 │ 83.3 │ 91.5 │ 98.1 │ 95.8 │ 93.2 │ 98.5 │ 96.4 |
| 2024 | FF-only Merge proposed | Task Avg. | 62.74 | peft · params=8B · trigger=CTBA · backbone=Llama-3.1-8B-Instruct | LoRATK: LoRA Once, Backdoor Everywhere in the Share-and-Play EcosystemSource quoteL1485: FF-only Merge │ 62.74 │ 99.50 |
| 2024 | FF-only Merge proposed non-standard slice | Backdoor Avg. | 99.50 | peft · params=8B · trigger=CTBA · backbone=Llama-3.1-8B-Instruct | LoRATK: LoRA Once, Backdoor Everywhere in the Share-and-Play EcosystemSource quoteL1485: FF-only Merge │ 62.74 │ 99.50 |
| 2024 | AIDE-generated data fine-tuning (Llama-3.2-3B) proposed | reported performance score | 51.0% | 0-shot · params=3B · backbone=Llama-3.2-3B | AIDE: Attribute-Guided MultI-Hop Data Expansion for Data Scarcity in Task-Specific Fine-tuningSource quoteL123: \multicolumn{2}{c|}{\multirow{2}*{Pretrained Llama-3.2-3B}} │ \textbf{{AIDE}~(Ours)} │ 58.7% │ 43.4% │ 56.6% │ 54.5% │ 71.4% │ 54.0% │ 56.8% │ 45.1% │ \textcolor{Blue}{67.6%} │ 51.0% │ 55.9% │ 1.5% |
| 2024 | LTM-enhanced MedAgent-Zero (LTM-rewritten experiences) proposed non-standard slice | accuracy | 95.83% | few-shot · subset=respiratory · repetitions=3 · interactions=40000 | Long Term Memory: The Foundation of AI Self-EvolutionSource quoteL630: LTM-enhanced │ 91.67 │ 94.44 │ 91.67 │ 93.06 │ 93.06 │ 91.67 │ 93.06 │ 95.83 │ 94.44 │ 93.06 |
| 2024 | AMPO proposed | number of explored prompts | 6.4 times | split: val · comparison=PromptAgent · optimization-iterations=5 | AMPO: Automatic Multi-Branched Prompt OptimizationSource quoteL262: Take the MedQA task as an example, we performed 5 iterations for 4 different methods, calculating the number of prompts they generated. For each iteration, APO generates 3 prompts from each of the 4 prompts of the previous iteration, and selects the 4 prompts with the best performance on the validation set for the next iteration, resulting in 240 exploration prompts. PromptAgent, using an MCTS Search strategy\cite{winands2008monte} with a depth of 3 and a breadth of 3, produces a total of 52 prompts after 5 iterations. Compared to PromptAgent and APO, AMPO\xspace{} uses 6.4 times and 48 times fewer explored prompts respectively, yet achieved performance improvements of 12% and 5.75%. |
| 2024 | AMPO proposed | number of explored prompts | 48 times | split: val · comparison=APO · optimization-iterations=5 | AMPO: Automatic Multi-Branched Prompt OptimizationSource quoteL262: Take the MedQA task as an example, we performed 5 iterations for 4 different methods, calculating the number of prompts they generated. For each iteration, APO generates 3 prompts from each of the 4 prompts of the previous iteration, and selects the 4 prompts with the best performance on the validation set for the next iteration, resulting in 240 exploration prompts. PromptAgent, using an MCTS Search strategy\cite{winands2008monte} with a depth of 3 and a breadth of 3, produces a total of 52 prompts after 5 iterations. Compared to PromptAgent and APO, AMPO\xspace{} uses 6.4 times and 48 times fewer explored prompts respectively, yet achieved performance improvements of 12% and 5.75%. |
| 2024 | MedGENIE-FID-Flan-T5 proposed | Accuracy | 53.1% | fine-tuned · reader=Fusion-in-Decoder · backbone=Flan-T5 | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteL779: MedGENIE-FID-Flan-T5 │ G (PMC-LLaMA) │ Fine-tuned │ 250M │ 53.1 |
| 2024 | MedGENIE-Phi-3-mini proposed | Accuracy | 64.7 | 1-shot · params=3.8B · backbone=Phi-3-mini | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteL776: \multirow{15}{*}{} │ MedGENIE-Phi-3-mini │ G ({PMC-LLaMA}) │ 1-shot │ 3.8B │ 64.7 |
| 2024 | PMC-LLaMA multi-view generated contexts vs MedWiki-retrieved contexts proposed | Recall@1 | 91% | reranker=BGE-large · generated-contexts=5 · retrieved-contexts=10 | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteL289: Precisely, we achieve a Recall@1 of 91%, 98%, and 96% on MedQA, MedMCQA, and MMLU, respectively. |
| 2024 | RAG² balanced retrieval (retrieval-component-only comparison) proposed | Accuracy | 55.3 | params=8B · backbone=Llama-3-8B-Instruct · comparison=retrieval-component-only · retrieval-top-k=1 | Rationale-Guided Retrieval Augmented Generation for Medical Question AnsweringSource quoteL316: + Ours │ 55.3 │ 51.3 │ 65.8 |
| 2024 | Qwen2-0.5B-RLEF proposed non-standard slice | Tglu accuracy | 0.289 | fine-tuned · params=0.5B · subset=diabetes-related (194 questions) · training-steps=11520 | Best of Both Worlds: Harmonizing LLM Capabilities in Decision-Making and Question-Answering for Treatment RegimesSource quoteL335: 0.289 |
| 2024 | Coke proposed | Accuracy | 0.778 | Full Coke model; benchmark-level accuracy on MedQA-USMLE. | Cost-efficient Knowledge-based Question Answering with Large Language ModelsSource quoteL237: 0.778 |
| 2024 | MPC-Internal proposed non-standard slice | AUROC | 6.2% | K=15 · subset=English | Multi-Perspective Consistency Enhances Confidence Estimation in Large Language ModelsSource quoteL175: Compared with SC, MPC-Internal significantly outperforms SC across all eight datasets which indicates that adding verifier perspective to the prompt in the SC method leads to more reliable confidence estimation. Taking MedQA as an example, MPC-Internal improves AUROC by 6.2% and reduce ECE by 0.095. Similar significant improvements are observed on other datasets as well. |
| 2024 | MPC-Internal proposed non-standard slice | ECE | 0.095 | K=15 · subset=English | Multi-Perspective Consistency Enhances Confidence Estimation in Large Language ModelsSource quoteL175: Compared with SC, MPC-Internal significantly outperforms SC across all eight datasets which indicates that adding verifier perspective to the prompt in the SC method leads to more reliable confidence estimation. Taking MedQA as an example, MPC-Internal improves AUROC by 6.2% and reduce ECE by 0.095. Similar significant improvements are observed on other datasets as well. |
| 2024 | OpenMedLM, Yi 34B (kNN few-shot CoT with shuffled-option ensemble/self-consistency) proposed non-standard slice | Benchmark Accuracy | 72.6% | split: test · few-shot · model=Yi 34B · params=34B · ensemble=5 shuffled-option runs · prompting=kNN-selected few-shot CoT | OpenMedLM: Prompt engineering can out-perform fine-tuning in medical question-answering with open-source large language modelsSource quoteL194: 72.6% for the Yi 34B foundation model. |
| 2024 | Q+R uncertainty expression (LLaMA2) proposed | AUROC | 0.574 | backbone=LLaMA2 · input-setting=Q+R | Can LLMs Learn Uncertainty on Their Own? Expressing Uncertainty Effectively in A Self-Training MannerSource quoteL221: 0.574 |
| 2023 | GPT-4 (Medprompt) proposed | Performance | 90.2% | split: test · few-shot · model=GPT-4 · protocol=Medprompt | Can Generalist Foundation Models Outcompete Special-Purpose Tuning? Case Study in MedicineSource quoteL196: US (4-option) │ 67.6 │ 86.5 │ 81.4 │ 90.2\tnote{**} |
| 2023 | Self-Explain proposed | Test accuracy | 57.5 | split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5 | SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by ThemselvesSource quoteL174: 57.5 |
| 2023 | Self-Explain w/ Multi-Exp proposed | Test accuracy | 59.6 | split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5 · self-explanations-per-exemplar=5 | SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by ThemselvesSource quoteL177: 59.6 |
| 2023 | Active Exemplar Selection (table label: Active Selection) proposed | Accuracy | 62.51 | In-context exemplar-selection comparison; model, split, and exemplar count are not spec… | In-Context Exemplars as Clues to Retrieving from Large Associative MemorySource quoteL152: Active Selection │ {62.51} │ {59.86} |
| 2023 | PMC-LLaMA proposed | ACC | 56.36 | params=13B | PMC-LLaMA: Towards Building Open-source Language Models for MedicineSource quoteL271: PMC-LLaMA │ 13B │ 56.36 │ 56.04 │ 77.9 │ 64.43 |
| 2023 | MedAgents MC framework (GPT-3.5) proposed | Acc | 63.7 | split: test · 0-shot · model=GPT-3.5-Turbo · option-domain-agents=2 · question-domain-agents=5 | MedAgents: Large Language Models as Collaborators for Zero-shot Medical ReasoningSource quoteL205: \quad - \texttt{GPT-3.5} │ 63.7 │ 58.3 │ 72.9 │ 65.3 │ 77.8 │ 81.3 │ 79.2 │ 82.7 │ 79.4 |
| 2023 | ChiMed-GPT proposed non-standard slice | Accuracy | 44.50 | 5-shot · subset=Chinese MCMLE | ChiMed-GPT: A Chinese Medical Large Language Model with Full Training Regime and Better Alignment to Human PreferencesSource quoteL420: 44.50 |
| 2023 | KnowGPT proposed | accuracy | 78.1% | fine-tuned · llm-tuning=none | KnowGPT: Knowledge Graph based Prompting for Large Language ModelsSource quoteL479: \texttt{KnowGPT} │ 81.8% │ 92.4% │ 78.1% |
| 2022 | MoEBQA proposed | Test Accuracy | 41.6 | split: test | Mixture-of-Experts for Biomedical Question AnsweringSource quoteL319: MoEBQA{} │ 39.9 │ 41.6 |