MedQA
107 papers · 217 extracted observations · question answering · language · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | KnowGPT SOTA frontier | 78.1% | 2024-01-01 | llm-tuning=none · Supplementary comparison with fine-tuned LLMs; the paper says KnowGPT uses no LLM tun… | KnowGPT: Knowledge Graph based Prompting for Large Language ModelsSource quote\texttt{KnowGPT} │ 81.8% │ 92.4% │ 78.1% |
| 2 | LLaMA 3.1-8B (trained) + GroupRAG (+2 variants) | 71.75% | 2026-03-01 | params=8B · Separate 400-question information-dense test set. The trained small-language-model va… | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 3 | MedGENIE-FID-Flan-T5 | 53.1% | 2024-01-01 | reader=Fusion-in-Decoder · backbone=Flan-T5 · Fine-tuned Fusion-In-Decoder reader grounded on PMC-LLaMA-generated contexts; supervi… | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteMedGENIE-FID-Flan-T5 │ G (PMC-LLaMA) │ Fine-tuned │ 250M │ 53.1 |
| 4 | Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned) | 20.59% | 2025-06-01 | params=8B · pruning=67% · backbone=LLaMA 3 8B · LightEval medical-QA evaluation; fine-tuned (FT) variant. | Enabling On-Device Medical AI Assistants via Input-Driven Saliency AdaptationSource quoteLLaMA\,3\,8B │ 67% Pruned (FT) │ 5.58 │ 29.45% │ 20.59% │ 43.15% |
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Claude Sonnet 4 baseline | Accuracy | 91.2% | multi-turn | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL4: Large language models (LLMs) are rapidly transitioning into medical clinical use, yet their reliability under realistic, multi-turn interactions remains poorly understood. Existing evaluation frameworks typically assess single-turn question answering under idealized conditions, overlooking the complexities of medical consultations where conflicting input, misleading context, and authority influence are common. We introduce MedQA-Followup, a framework for systematically evaluating multi-turn robustness in medical question answering. Our approach distinguishes between shallow robustness (resisting misleading initial context) and deep robustness (maintaining accuracy when answers are challenged across turns), while also introducing an indirect–direct axis that separates contextual framing (indirect) from explicit suggestion (direct). Using controlled interventions on the MedQA dataset, we evaluate five state-of-the-art LLMs and find that while models perform reasonably well under shallow perturbations, they exhibit severe vulnerabilities in multi-turn settings, with accuracy dropping from 91.2% to as low as 13.5% for Claude Sonnet 4. Counterintuitively, indirect, context-based interventions are often more harmful than direct suggestions, yielding larger accuracy drops across models and exposing a significant vulnerability for clinical deployment. Further compounding analyses reveal model differences, with some showing further performance drops under repeated interventions while others partially recovering or even improving. These findings highlight multi-turn robustness as a critical but underexplored dimension for safe and reliable deployment of medical LLMs. Dataset and code available on |
| 2025 | Claude Sonnet 4 baseline | Accuracy | 13.5% | multi-turn | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL4: Large language models (LLMs) are rapidly transitioning into medical clinical use, yet their reliability under realistic, multi-turn interactions remains poorly understood. Existing evaluation frameworks typically assess single-turn question answering under idealized conditions, overlooking the complexities of medical consultations where conflicting input, misleading context, and authority influence are common. We introduce MedQA-Followup, a framework for systematically evaluating multi-turn robustness in medical question answering. Our approach distinguishes between shallow robustness (resisting misleading initial context) and deep robustness (maintaining accuracy when answers are challenged across turns), while also introducing an indirect–direct axis that separates contextual framing (indirect) from explicit suggestion (direct). Using controlled interventions on the MedQA dataset, we evaluate five state-of-the-art LLMs and find that while models perform reasonably well under shallow perturbations, they exhibit severe vulnerabilities in multi-turn settings, with accuracy dropping from 91.2% to as low as 13.5% for Claude Sonnet 4. Counterintuitively, indirect, context-based interventions are often more harmful than direct suggestions, yielding larger accuracy drops across models and exposing a significant vulnerability for clinical deployment. Further compounding analyses reveal model differences, with some showing further performance drops under repeated interventions while others partially recovering or even improving. These findings highlight multi-turn robustness as a critical but underexplored dimension for safe and reliable deployment of medical LLMs. Dataset and code available on |
| 2025 | GPT-4.1 baseline | Accuracy | 88.2 | multi-turn · intervention=direct-inc_letter · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL397: \textbf{\texttt{inc\_letter} (avg)} │ 42.9 (-53.3%) │ 88.2 (-5.0%) │ 85.2 (-6.4%) │ 54.2 (-15.5%) │ 69.1 (-18.3%) |
| 2025 | GPT-4.1 baseline | Accuracy | 58.0 | multi-turn · intervention=indirect-context · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL403: \textbf{\texttt{context} (avg)} │ 45.6 (-50.3%) │ 58.0 (-37.5%) │ 55.8 (-38.7%) │ 40.0 (-37.6%) │ 56.9 (-32.8%) |
| 2025 | GPT-4.1 mini baseline | Accuracy | 85.2 | multi-turn · intervention=direct-inc_letter · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL397: \textbf{\texttt{inc\_letter} (avg)} │ 42.9 (-53.3%) │ 88.2 (-5.0%) │ 85.2 (-6.4%) │ 54.2 (-15.5%) │ 69.1 (-18.3%) |
| 2025 | GPT-4.1 mini baseline | Accuracy | 55.8 | multi-turn · intervention=indirect-context · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL403: \textbf{\texttt{context} (avg)} │ 45.6 (-50.3%) │ 58.0 (-37.5%) │ 55.8 (-38.7%) │ 40.0 (-37.6%) │ 56.9 (-32.8%) |