MedQA

107 papers · 217 extracted observations · question answering · language · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

16.038.260.582.7202420252026MedGENIE-FID-Flan-T5: 53.1 (2024)KnowGPT: 78.1 (2024)Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned): 20.59 (2025)LLaMA 3.1-8B (trained) + Naive RAG: 58.25 (2026)LLaMA 3.1-8B (trained) + CoT prompting: 61.5 (2026)LLaMA 3.1-8B (trained) + GroupRAG: 71.75 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026LLM with E1 few-shot prompt intervention based on nonspecific systemic symptoms proposedbenchmark accuracy84.3%few-shot · subset=analyzed casesVeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge Graphs
Source quote
L657: Under this limited prompt modification, the eight previously incorrect cases associated with this error pattern were corrected, and the benchmark accuracy on the analyzed cases increased from 81.5% to 84.3%.
2026LLM with E2 few-shot prompt intervention based on pruritus or similar dermatologic symptoms proposedbenchmark accuracy85.5%few-shot · subset=analyzed setVeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge Graphs
Source quote
L685: Under this limited intervention, the previously incorrect cases matching this pattern were corrected, and the benchmark accuracy in this run increased from 81.5% to 85.5% on the analyzed set.
2026GPT-3 (k-NN) proposedF1@315.08few-shot · k=5 · retrieval=k-NN · similarity=cosine · embedding-model=MPNetBeyond Fine-Tuning: In-Context Learning and Chain-of-Thought for Reasoned Distractor Generation
Source quote
L282: ICL also outperforms Text2Text models. While the contrastive-based model provides steady improvements over base fine-tuning and multi-task learning in all datasets and still achieves the highest F1@3 score on SciQ, it remains less competitive with longer distractor tokens and diverse domains, such as the medical field. In fact, ICL shows consistently stronger performance than recent SOTA contrastive-based models in the DG task. Its F1@3 score rises from 15.70 to 19.69 on MCQ and 13.67 to 24.44 on MCQL, with even larger improvements on datasets with longer distractor lengths: 10.39 to 18.10 on ARC-Easy, 5.47 to 15.29 on ARC-Challenge, and 3.50 to 15.08 on MedQA.
2024LTM-enhanced MedAgent-Zero (LTM-rewritten experiences) proposed non-standard sliceaccuracy95.83%few-shot · subset=respiratory · repetitions=3 · interactions=40000Long Term Memory: The Foundation of AI Self-Evolution
Source quote
L630: LTM-enhanced │ 91.67 │ 94.44 │ 91.67 │ 93.06 │ 93.06 │ 91.67 │ 93.06 │ 95.83 │ 94.44 │ 93.06
2024OpenMedLM, Yi 34B (kNN few-shot CoT with shuffled-option ensemble/self-consistency) proposed non-standard sliceBenchmark Accuracy72.6%split: test · few-shot · model=Yi 34B · params=34B · ensemble=5 shuffled-option runs · prompting=kNN-selected few-shot CoTOpenMedLM: Prompt engineering can out-perform fine-tuning in medical question-answering with open-source large language models
Source quote
L194: 72.6% for the Yi 34B foundation model.
2023GPT-4 (Medprompt) proposedPerformance90.2%split: test · few-shot · model=GPT-4 · protocol=MedpromptCan Generalist Foundation Models Outcompete Special-Purpose Tuning? Case Study in Medicine
Source quote
L196: US (4-option) │ 67.6 │ 86.5 │ 81.4 │ 90.2\tnote{**}
2023Self-Explain proposedTest accuracy57.5split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by Themselves
Source quote
L174: 57.5
2023Self-Explain w/ Multi-Exp proposedTest accuracy59.6split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5 · self-explanations-per-exemplar=5SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by Themselves
Source quote
L177: 59.6