MedQA
107 papers · 217 extracted observations · question answering · language · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | KnowGPT SOTA frontier | 78.1% | 2024-01-01 | llm-tuning=none · Supplementary comparison with fine-tuned LLMs; the paper says KnowGPT uses no LLM tun… | KnowGPT: Knowledge Graph based Prompting for Large Language ModelsSource quote\texttt{KnowGPT} │ 81.8% │ 92.4% │ 78.1% |
| 2 | LLaMA 3.1-8B (trained) + GroupRAG (+2 variants) | 71.75% | 2026-03-01 | params=8B · Separate 400-question information-dense test set. The trained small-language-model va… | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 3 | MedGENIE-FID-Flan-T5 | 53.1% | 2024-01-01 | reader=Fusion-in-Decoder · backbone=Flan-T5 · Fine-tuned Fusion-In-Decoder reader grounded on PMC-LLaMA-generated contexts; supervi… | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteMedGENIE-FID-Flan-T5 │ G (PMC-LLaMA) │ Fine-tuned │ 250M │ 53.1 |
| 4 | Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned) | 20.59% | 2025-06-01 | params=8B · pruning=67% · backbone=LLaMA 3 8B · LightEval medical-QA evaluation; fine-tuned (FT) variant. | Enabling On-Device Medical AI Assistants via Input-Driven Saliency AdaptationSource quoteLLaMA\,3\,8B │ 67% Pruned (FT) │ 5.58 │ 29.45% │ 20.59% │ 43.15% |
Showing 5 of 5 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Qwen2.5-0.5B-Instruct (chain-of-thought) baseline | accuracy | 28.4 | cot · params=0.5B | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL184: We evaluate whether PRA enables the drop-in replacement of frozen policy models without requiring any retraining. Table~\ref{tab:policy_reward_vertical} shows that PRA, despite being trained exclusively on reasoning traces from Qwen3-4B, generalizes well across a diverse set of policy models spanning both smaller and larger sizes. In several cases, models that perform poorly under standard decoding exhibit especially large relative improvements when paired with PRA, with the largest gains observed for smaller policy models. For example, on Qwen2.5-0.5B-Instruct, PRA improves MedQA accuracy from 28.4 to 54.1, corresponding to a 90.5% relative improvement over chain-of-thought. |
| 2026 | Phi-4-14B, unwatermarked baseline non-standard slice | faulty-but-correct rate (F&C) | 11.4% | cot · FPR=1% · TPR=at least 99% · params=14B · watermark=none | Marking the Wrong Symptoms: Evaluating LLM Watermarks in Medical TextsSource quoteL176: The faulty-but-correct rate (F\ │ C) (i.e., correct letter with at least one flagged defect) climbs from 11.4% to 26.3% on Phi-4-14B under SynthID while accuracy drops only -3.2\,pp, and similarly on OpenBioLLM-70B F\ │ C more than doubles (12.9% \to 27.5%, {} (*)). |
| 2026 | Phi-4-14B with SynthID baseline non-standard slice | faulty-but-correct rate (F&C) | 26.3% | cot · FPR=1% · TPR=at least 99% · params=14B · watermark=SynthID | Marking the Wrong Symptoms: Evaluating LLM Watermarks in Medical TextsSource quoteL176: The faulty-but-correct rate (F\ │ C) (i.e., correct letter with at least one flagged defect) climbs from 11.4% to 26.3% on Phi-4-14B under SynthID while accuracy drops only -3.2\,pp, and similarly on OpenBioLLM-70B F\ │ C more than doubles (12.9% \to 27.5%, {} (*)). |
| 2025 | AMG-RAG without CoT reasoning ablation | accuracy | 66.69% | cot · removed-component=chain-of-thought reasoning | Agentic Medical Knowledge Graphs Enhance Medical Question Answering: Bridging the Gap Between LLMs and Evolving Medical KnowledgeSource quoteL247: Table~\ref{tab:medqa_results} presents a comprehensive comparison of various RAG models evaluated on the MEDQA benchmark. This includes models with different retrieval mechanisms and model sizes, enabling a head-to-head evaluation of \gls{myrag} with other state-of-the-art baselines such as Self-RAG \citep{asai2023self}, HyDE \citep{gao2022precise}, GraphRAG \citep{edge2024local}, and MedRAG \citep{zhao2025medrag}. The results clearly show that \gls{myrag} configured with the PubMed-\gls{mkg} and an 8B LLM backbone achieves the highest accuracy of 73.92%, surpassing all competing models. Notably, ablation results indicate that removing search functionality or CoT reasoning significantly degrades accuracy (dropping to 67.16% and 66.69%, respectively), confirming the essential role of structured retrieval and reasoning components in complex question answering. Other baseline models such as Gemini-pro and PMC-LLaMA demonstrate weaker performance, further validating the efficacy of domain-aware retrieval and reasoning modules proposed in \gls{myrag}. Importantly, the domain specificity and freshness of PubMedSearch provide a significant advantage in retrieving relevant knowledge that general-purpose search modules often fail to deliver. |
| 2022 | Flan-PaLM 540B baseline | Multiple-choice question accuracy | 67.6% | split: test · cot · params=540B · options=4 | Large language models encode clinical knowledgeSource quoteL471: MedQA 4 options │ 60.3 │ 67.6 |