IXI

45 papers · 131 extracted observations · image super resolution · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

29.933.336.740.1202220242025Cohf-T (Ours-L, final variant): 31.82 (2022)Cohf-T (Ours-L, final variant): 32.79 (2022)Cohf-T (Ours-L, final variant): 35.73 (2022)EqSim + Com + Adv: 36.73 (2022)DefSim + Com + Adv: 36.99 (2022)Blaze3DM: 38.86 (2024)Blaze3DM: 39.35 (2024)Deform-Mamba (Our): 30.6 (2024)I2I-Galip-M: 32.34 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 68 of 68 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026OpenBrain lower-risk selection proposed non-standard slice96-label macro Dice0.769fixed-budget-training-1-000-case-lower-risk-selectionOpenBrain: An Auditable Generated-Label Release for Whole-Brain MRI Parcellation
Source quote
L573: 0.769 [0.764, 0.775]
2026OpenBrain QC-7 aggregate risk (lowest-risk retention) proposed non-standard slice96-label macro Dice difference+1.3 pplowest-risk-25-retentionOpenBrain: An Auditable Generated-Label Release for Whole-Brain MRI Parcellation
Source quote
L522: +1.3 [+1.2, +1.4]
2026EvoML proposednormalized PSNR0.7859split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L976: on FastMRI against the next-best 0.8579 and 0.7859 on IXI
2026PAS-Mamba proposedPSNR40.43 dBRadial undersampling, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L293: In our experiments, PAS-Mamba consistently achieved the best performance across different datasets and undersampling masks. Notably, under the IXI radial ×2 setting, it achieves a PSNR of 40.43 dB and an SSIM of 0.9805. Unlike most existing methods that treat the frequency domain as a unified representation, PAS-Mamba explicitly decouples phase and amplitude modeling, which better aligns with the intrinsic characteristics of k-space. Moreover, by combining Mamba-based global dependency modeling in the frequency domain with locality-preserving LocalMamba in the image domain, PAS-Mamba effectively balances global structure recovery and local detail preservation. In addition, the proposed Dual-Domain Complementary Fusion Module (DDCFM) enables more effective integration of spatial- and frequency-domain features, reducing feature interference and further improving reconstruction quality. Beyond these general trends, the superior performance of PAS-Mamba can be attributed to its key design choices.
2026PAS-Mamba proposedSSIM0.9805Radial undersampling, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L293: In our experiments, PAS-Mamba consistently achieved the best performance across different datasets and undersampling masks. Notably, under the IXI radial ×2 setting, it achieves a PSNR of 40.43 dB and an SSIM of 0.9805. Unlike most existing methods that treat the frequency domain as a unified representation, PAS-Mamba explicitly decouples phase and amplitude modeling, which better aligns with the intrinsic characteristics of k-space. Moreover, by combining Mamba-based global dependency modeling in the frequency domain with locality-preserving LocalMamba in the image domain, PAS-Mamba effectively balances global structure recovery and local detail preservation. In addition, the proposed Dual-Domain Complementary Fusion Module (DDCFM) enables more effective integration of spatial- and frequency-domain features, reducing feature interference and further improving reconstruction quality. Beyond these general trends, the superior performance of PAS-Mamba can be attributed to its key design choices.
2025Tetrahedron-Net(TM-bspl) proposedDSC0.765split: test · unsupervised · decoder=DenseUNetTetrahedron-Net for Medical Image Registration
Source quote
L372: Tetrahedron-Net(TM-bspl) │ 0.765 │ <0.0001
2025MDPG proposedPSNR27.50split: val · acceleration=8× · sampling-rate=0.04cMDPG: Multi-domain Diffusion Prior Guidance for MRI Reconstruction
Source quote
L132: MDPG (ours) │ 27.50 │ 0.833 │ 0.0278 │ 31.00 │ 0.914 │ 0.0124
2025MDPG proposedSSIM0.833split: val · acceleration=8× · sampling-rate=0.04cMDPG: Multi-domain Diffusion Prior Guidance for MRI Reconstruction
Source quote
L132: MDPG (ours) │ 27.50 │ 0.833 │ 0.0278 │ 31.00 │ 0.914 │ 0.0124
2025MDPG proposedNMSE0.0278split: val · acceleration=8× · sampling-rate=0.04cMDPG: Multi-domain Diffusion Prior Guidance for MRI Reconstruction
Source quote
L132: MDPG (ours) │ 27.50 │ 0.833 │ 0.0278 │ 31.00 │ 0.914 │ 0.0124
2025HealthGPT-M3 proposedSSIM78.194× super-resolution.HealthGPT: A Medical Large Vision-Language Model for Unifying Comprehension and Generation via Heterogeneous Knowledge Adaptation
Source quote
L304: In contrast, our method significantly mitigates this issue. Specifically, \texttt{HealthGPT-M3} excels in key metrics such as SSIM, PSNR, and ISE, achieving scores of 78.19, 32.76, and 34.47, respectively.
2025TCIP proposedASSD↓0.470split: test · subset=58 volumes; 58×57 paired samples · resolution=58x57 · TCI-window-size=3TCIP: Threshold-Controlled Iterative Pyramid Network for Deformable Medical Image Registration
Source quote
L354: 1.229 │ 0.470 │ 0.230
2025TCIP proposedMSE (10 (-3))0.230split: test · subset=58 volumes; 58×57 paired samples · resolution=58x57 · TCI-window-size=3TCIP: Threshold-Controlled Iterative Pyramid Network for Deformable Medical Image Registration
Source quote
L354: 1.229 │ 0.470 │ 0.230
2025ENMKL-KRR proposedMean Squared Error25.25Regression predicting age.Elastic-Net Multiple Kernel Learning: Combining Multiple Data Sources for Prediction
Source quote
L579: ENMKL-KRR │ 25.25 │ 0.54 │ 116
2025BARL proposedDice0.8979semi-supervised · labeled-data=5%BARL: Bilateral Alignment in Representation and Label Spaces for Semi-Supervised Volumetric Medical Image Segmentation
Source quote
L322: \multirow{-13}{*}{5 %} │ Ours │ {\color[HTML]{000000} 0.8979} │ {\color[HTML]{000000} 1.0379} │ {\color[HTML]{000000} 0.6531} │ {\color[HTML]{000000} 0.8082}
2025BARL proposedHD1.0379semi-supervised · labeled-data=5%BARL: Bilateral Alignment in Representation and Label Spaces for Semi-Supervised Volumetric Medical Image Segmentation
Source quote
L322: \multirow{-13}{*}{5 %} │ Ours │ {\color[HTML]{000000} 0.8979} │ {\color[HTML]{000000} 1.0379} │ {\color[HTML]{000000} 0.6531} │ {\color[HTML]{000000} 0.8082}
2025MambaMDN proposedPSNR39.30 dBacceleration=×8Mamba-Based Modality Disentanglement Network for Multi-Contrast MRI Reconstruction
Source quote
L232: MambaMDN (ours) │ 41.92 │ 0.9806 │ 2.211 │ 39.30 │ 0.9724 │ 2.981
2025HACA3 proposedAccuracy (↑)0.383target-scanner=IOP · training-exposure=unseenContrastive Anatomy-Contrast Disentanglement: A Domain-General MRI Harmonization Method
Source quote
L202: HACA3 │ 0.226 │ 0.688 │ 0.451 │ 0.469 │ 0.0 │ 0.383 │ 0.57
2025Ours (uCMS + IrR) proposedPSNR35.16scale-factor=4× · reconstruction=2D slice-basedDecoupling Multi-Contrast Super-Resolution: Pairing Unpaired Synthesis with Implicit Representations
Source quote
L242: 35.16
2025Ours (uCMS + IrR) proposedPSNR32.53scale-factor=8× · reconstruction=2D slice-basedDecoupling Multi-Contrast Super-Resolution: Pairing Unpaired Synthesis with Implicit Representations
Source quote
L310: 32.53
2025FgC2F-UDiff (Our method) proposedPSNR32.49 dBsynthesis=many-to-one · target-modality=PD · input-modalities=T1,T2FgC2F-UDiff: Frequency-Guided and Coarse-to-Fine Unified Diffusion Model for Multi-Modality Missing MRI Synthesis
Source quote
L330: \multirow{2}{*}{Our method} │ 32.49 │ 0.971 │ 15.73 │ 18.13 │ 33.77 │ 0.973 │ 14.52 │ 16.38
2024pixel2pixel with AGI-Net proposedPSNR34.96framework=pixel2pixel · modalities=T1,T2-to-PDCross Group Attention and Group-wise Rolling for Multimodal Medical Image Synthesis
Source quote
L192: \cellcolor[HTML]{D3EAF8}AGI-Net │ \cellcolor[HTML]{D3EAF8}34.96 │ \cellcolor[HTML]{D3EAF8}96.62
2024pixel2pixel with AGI-Net proposedSSIM96.62framework=pixel2pixel · modalities=T1,T2-to-PDCross Group Attention and Group-wise Rolling for Multimodal Medical Image Synthesis
Source quote
L192: \cellcolor[HTML]{D3EAF8}AGI-Net │ \cellcolor[HTML]{D3EAF8}34.96 │ \cellcolor[HTML]{D3EAF8}96.62
2024AGI-Net proposedPSNR32.63 dBframework=pixel2pixel · modalities=T1,T2-to-PD · translation=3-pixelCross Group Attention and Group-wise Rolling for Multimodal Medical Image Synthesis
Source quote
L153: \cellcolor[HTML]{D3EAF8} AGI-Net │ \cellcolor[HTML]{D3EAF8}32.63_{(\textcolor{blue}{\uparrow1.49})}
2024I2I-Galip-M proposedPSNR32.34split: test · regime=multi-domain · direction=T2-weighted-to-PDI2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIP
Source quote
L140: I2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20
2024I2I-Galip-M proposedSSIM95.74split: test · regime=multi-domain · direction=T2-weighted-to-PDI2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIP
Source quote
L140: I2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20
2024Blaze3DM proposedPSNR ↑39.35split: test · sampling=Poisson · acceleration=×8Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L245: Blaze3DM (Ours) │ 39.35
2024Blaze3DM proposedPSNR ↑38.86split: test · anisotropy=×4Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L246: 0.957 │ 0.952 │ 0.951 │ 38.86 │ 0.951 │ 0.949 │ 0.949
2024Deform-Mamba (Our) proposedPSNR30.60split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024Base+ISS2D+SPL (SMamba-UNet) proposedPSNR33.36upsampling=2×Self-Prior Guided Mamba-UNet Networks for Medical Image Super-Resolution
Source quote
L189: Base+ISS2D+SPL (SMamba-UNet) │ \ding{51} │ \ding{51} │ \ding{51} │ 33.36 │ 0.9355
2024Base+ISS2D+SPL (SMamba-UNet) proposedSSIM0.9355upsampling=2×Self-Prior Guided Mamba-UNet Networks for Medical Image Super-Resolution
Source quote
L189: Base+ISS2D+SPL (SMamba-UNet) │ \ding{51} │ \ding{51} │ \ding{51} │ 33.36 │ 0.9355
2024UA-MT proposedDSC0.04split: test · semi-supervised · comparison=U-Net · labeled-samples=1Guidelines for Cerebrovascular Segmentation: Managing Imperfect Annotations in the context of Semi-Supervised Learning
Source quote
L374: For example the improvement in the DSC between UA-MT and U-Net when using 1 labeled sample is 0.04 but it decreases to 0.009 when using 9 labeled samples on IXI dataset. Qualitative results confirm these findings (see Figs. \ref{fig:visual_results_xp1_Bullitt} and \ref{fig:visual_results_xp1_IXI}). In addition, we can observe that the segmentations generated by the supervised U-Net exhibit significant noise, as confirmed by the higher standard deviations, particularly when only one sample is used for training. This noise is typically attributed to an overfitting problem.
2024UA-MT proposedDSC0.009split: test · semi-supervised · comparison=U-Net · labeled-samples=9Guidelines for Cerebrovascular Segmentation: Managing Imperfect Annotations in the context of Semi-Supervised Learning
Source quote
L374: For example the improvement in the DSC between UA-MT and U-Net when using 1 labeled sample is 0.04 but it decreases to 0.009 when using 9 labeled samples on IXI dataset. Qualitative results confirm these findings (see Figs. \ref{fig:visual_results_xp1_Bullitt} and \ref{fig:visual_results_xp1_IXI}). In addition, we can observe that the segmentations generated by the supervised U-Net exhibit significant noise, as confirmed by the higher standard deviations, particularly when only one sample is used for training. This noise is typically attributed to an overfitting problem.
2023TransMRSR proposedPSNR30.85 dBsplit: test · scale=×8 · modality=T1wTransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-Resolution
Source quote
L142: TransMRSR │ \color{red}38.56 │ \color{red}0.9862 │ \color{red}30.85 │ \color{red}0.9451 │ \color{red}36.98 │ \color{red}0.9793 │ \color{red}30.32 │ \color{red}0.9353
2023TransMRSR proposedSSIM0.9451split: test · scale=×8 · modality=T1wTransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-Resolution
Source quote
L142: TransMRSR │ \color{red}38.56 │ \color{red}0.9862 │ \color{red}30.85 │ \color{red}0.9451 │ \color{red}36.98 │ \color{red}0.9793 │ \color{red}30.32 │ \color{red}0.9353
2023Conformal (MCCQR with conformal prediction) proposedMAD4.40split: test · training-data=NAKO normative sample (N=10,691)From Group-Differences to Single-Subject Probability: Conformal Prediction-based Uncertainty Estimation for Brain-Age Modeling
Source quote
L118: MAD of 4.40, in the MDD sample of the MACS a MAD of 3.71 and in the BiDirect our model obtains a
2023TM-SPR_diff proposedPercentage of all non-positive Jacobian determinant (%|J|≤0)0.03%split: val · eta=2.0 · loss=no Dice lossSpatially-varying Regularization with Conditional Transformer for Unsupervised Image Registration
Source quote
L111: TM-SPR_{\text{diff}} │ 0.852±0.014 │ 1.597±0.345 │ 0.082±0.03 │ TM-SPR_{\text{diff}} │ 0.762±0.123 │ 0.03% │ 0%
2023TM-SPR_diff proposed%NDV0%split: val · eta=2.0 · loss=no Dice lossSpatially-varying Regularization with Conditional Transformer for Unsupervised Image Registration
Source quote
L111: TM-SPR_{\text{diff}} │ 0.852±0.014 │ 1.597±0.345 │ 0.082±0.03 │ TM-SPR_{\text{diff}} │ 0.762±0.123 │ 0.03% │ 0%
2023Proposed method with quadratic age model proposedMAE4.36 yearssplit: test · subjects=562 · age-model=quadratic · validation=nested 5-fold cross-validation · age-discretization=20 intervalsA lightweight generative model for interpretable subject-level prediction
Source quote
L2242: 4.36
2022EqSim + Com + Adv proposedPSNR36.73split: test · pairing=non-aligned · modality=T2-to-PD · resolution=64x64 · training_patch=64×64×64 · data_generation=semi-synthetic deformationsDeformation equivariant cross-modality image synthesis with paired non-aligned training data
Source quote
L400: EqSim + Com + Adv │ 36.73 │ 0.9557 │ 1.183 │ 0.6975
2022DefSim + Com + Adv proposedPSNR36.99split: test · pairing=non-aligned · modality=T2-to-PD · resolution=64x64 · training_patch=64×64×64 · data_generation=semi-synthetic deformationsDeformation equivariant cross-modality image synthesis with paired non-aligned training data
Source quote
L401: DefSim + Com + Adv │ 36.99 │ 0.9573 │ 1.181 │ 0.6671
2022LKU-Net-4,5 proposedDice score0.752split: test · registration-type=non-diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from
2022LKU-Net-8,5 proposedDice score0.757split: test · registration-type=non-diffeomorphic · first-layer-kernels=8 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022LKU-Net-diff-4,5 proposedDice score0.746split: test · registration-type=diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022MMT (random-missing model) proposedPSNR40.69 dBsplit: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022MMT (random-missing model) proposedSSIM0.977split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022MMT (random-missing model) proposedLPIPS0.069split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022Cohf-T (Ours-L, final variant) proposedPSNR35.73split: test · modality=T2WI · upsampling=2×Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
Source quote
L215: Ours-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129
2022Cohf-T (Ours-L, final variant) proposedPSNR32.79split: test · modality=T2WI · upsampling=3×Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
Source quote
L215: Ours-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129
2022Cohf-T (Ours-L, final variant) proposedPSNR31.82split: test · modality=T2WI · upsampling=4×Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
Source quote
L215: Ours-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129
2021TTM+PC-RNN proposedPSNR0.64 dBsplit: test · acceleration=4× · reference-matching=mutual informationReference-based Magnetic Resonance Image Reconstruction Using Texture Transforme
Source quote
L113: From Table~\ref{tab1}, we can make the following observations: (i) Naively treating the reference image as an additional input cannot improve the reconstruction performance. Due to lacking an efficient mechanism of searching and transferring the texture information in reference images, it results in slightly lower performance across four different methods. (ii) By using the proposed TTM, we are able to achieve obvious improvements as compared to models that naively use the reference images and the original models. (iii) The gain in performance achieved by TTM are consistent across different reconstruction methods, as shown in Fig.~\ref{fig4}. Even for the state-of-the-art CRNN method (i.e. PC-RNN~\cite{pcrnn}), the proposed TTM still can improve the reconstruction quality by 0.64 dB in term of PSNR. Fig.~\ref{fig3} shows the
2021FIL: Overall proposed non-standard sliceaverage DSC (labelling similarity)0.785modalities=T1w versus T2w and PDwFactorisation-Based Image Labelling
Source quote
L709: FIL: Overall │ 0.785 │ 0.782 │ 0.786
2021FIL: Guys Hospital (Philips 1.5T) proposed non-standard sliceaverage DSC (labelling similarity)0.835site=Guys Hospital · scanner=Philips 1.5T · modalities=T1w versus T2w and PDwFactorisation-Based Image Labelling
Source quote
L706: FIL: Guys Hospital (Philips 1.5T) │ 0.835 │ 0.848 │ 0.830
2021FIL: Hammersmith Hospital (Philips 3T) proposed non-standard sliceaverage DSC (labelling similarity)0.776site=Hammersmith Hospital · scanner=Philips 3T · modalities=T1w versus T2w and PDwFactorisation-Based Image Labelling
Source quote
L707: FIL: Hammersmith Hospital (Philips 3T) │ 0.776 │ 0.754 │ 0.784
2021UGAC proposedSSIM0.83pairing=unpaired · test-subset=patients aged ≥45 · translation=T1w-to-T2w · training-subset=patients aged <45Uncertainty-aware Generalized Adaptive CycleGAN
Source quote
L391: Table~\ref{tab:abl2} shows the performance of all the models when trained and evaluated on different splits. Zooming into the young \rightarrow old experiments, where the model is trained on ``young'' patients and evaluated on ``old'' patients, our model has an SSIM and PSNR of 0.83 and 25.8, respectively, compared to that of 0.71 and 19.4 for the best performing baseline. We see a similar trend for the other split training on lighter patients and evaluating on heavier patients (see Table~\ref{tab:abl2}-Col 3).
2021UGAC proposedPSNR25.8pairing=unpaired · test-subset=patients aged ≥45 · translation=T1w-to-T2w · training-subset=patients aged <45Uncertainty-aware Generalized Adaptive CycleGAN
Source quote
L391: Table~\ref{tab:abl2} shows the performance of all the models when trained and evaluated on different splits. Zooming into the young \rightarrow old experiments, where the model is trained on ``young'' patients and evaluated on ``old'' patients, our model has an SSIM and PSNR of 0.83 and 25.8, respectively, compared to that of 0.71 and 19.4 for the best performing baseline. We see a similar trend for the other split training on lighter patients and evaluating on heavier patients (see Table~\ref{tab:abl2}-Col 3).
2021CSC\ell_4Net proposedPSNR36.45 dBsplit: test · training=unsupervised-unpaired · translation=T2-w-to-PD-w · test_samples=100Brain Image Synthesis With Unsupervised Multivariate Canonical CSCl4Net
Source quote
L176: PSNR (dB) │ 30.49 │ 32.53 │ 32.66 │ 32.75 │ 33.11 │ 36.45
2020HLH-GAN (SRI) proposedPSNR32.04 dBsplit: test · variant=simultaneous super-resolution and inpainting · modality=T2-weighted MRISuper-Resolution and Inpainting with Degraded and Upgraded Generative Adversarial Networks
Source quote
L558: 32.04
2020HLH-GAN (SR+I) proposedPSNR28.59 dBsplit: test · variant=super-resolution followed by inpainting · modality=T2-weighted MRISuper-Resolution and Inpainting with Degraded and Upgraded Generative Adversarial Networks
Source quote
L560: 28.59
2020HLH-GAN (I+SR) proposedPSNR28.32 dBsplit: test · variant=inpainting followed by super-resolution · modality=T2-weighted MRISuper-Resolution and Inpainting with Degraded and Upgraded Generative Adversarial Networks
Source quote
L562: 28.32
2019Ours one-set reconstruction-with-denoising solution proposedPSNR28 dBnoise=Rician, level 20 · sequence=T1-weighted · configuration=one-set reconstruction with denoisingConverged Deep Framework Assembling Principled Modules for CS-MRI
Source quote
L472: Our framework naturally embeds the two-stage deep denoiser into iterations for reconstruction. We investigate the performance of this one-set solution for reconstruction with Rician noise on T_1-weighted data in the IXI dataset. The parameters \rho_1, \lambda_1 and \lambda_2 in~\eqref{eq:rician_sub_z} and~\eqref{eq:rician_sub_x} are set as 0.01, 1.0 and 1.0, respectively. For fair comparisons, we cascade RiceVST or our two-stage denoiser to the other reconstruction algorithms as post-processing. The right plot of Fig.~\ref{fig:NoisySigma} illustrates PSNR values reconstructed by the comparative algorithms with RiceVST (x-axis) and our two-stage denoiser (y-axis) cascaded. The brown triangle denotes PSNR (28dB) obtained by our one-set solution. This figure shows that a) our framework combing reconstruction with denoising produces the best quality over the other reconstruction algorithms with post-processing, and b) our learnable two-stage denoiser performs better than RiceVST as post-pocessing for reconstruction. Figure~\ref{fig:noisyDetail} provides an visual illustration for reconstruction with noise, where our framework also preserves more details and introduces lower errors.
2019TPADMM proposedPSNR31.33subset=25 T1-weighted MRI scans · sampling-ratio=30% · sampling-pattern=CartesianInvestigating Customization Strategies and Convergence Behaviors of Task-Specific ADMM
Source quote
L919: TPADMM │ 31.33 │ 0.1003 │ 35.51 │ 0.0622 │ 39.93 │ 0.0374
2019TPADMM proposedPSNR35.51subset=25 T1-weighted MRI scans · sampling-ratio=30% · sampling-pattern=RadialInvestigating Customization Strategies and Convergence Behaviors of Task-Specific ADMM
Source quote
L919: TPADMM │ 31.33 │ 0.1003 │ 35.51 │ 0.0622 │ 39.93 │ 0.0374
2019TPADMM proposedPSNR39.93subset=25 T1-weighted MRI scans · sampling-ratio=30% · sampling-pattern=GaussianInvestigating Customization Strategies and Convergence Behaviors of Task-Specific ADMM
Source quote
L919: TPADMM │ 31.33 │ 0.1003 │ 35.51 │ 0.0622 │ 39.93 │ 0.0374
2018CSN (C1) proposedPSNR41.28 dBsplit: test · scale=×2 · downsampling=bicubic · training-setup=C1 single-sliceChannel Splitting Network for Single MR Image Super-Resolution
Source quote
L279: CSN [Ours] │ ×2 │ {\textcolor[rgb]{1,0,0}{41.28 / 0.9895}} │ {\textcolor[rgb]{1,0,0}{38.27 / 0.9810}} │ {\textcolor[rgb]{1,0,0}{39.71 / 0.9863}} │ {\textcolor[rgb]{1,0,0}{41.77 / 0.9897}} │ {\textcolor[rgb]{1,0,0}{38.62 / 0.9813}} │ {\textcolor[rgb]{1,0,0}{40.47 / 0.9868}}
2018CSN (C1) proposedPSNR33.68 dBsplit: test · scale=×3 · downsampling=k-space truncation · training-setup=C1 single-sliceChannel Splitting Network for Single MR Image Super-Resolution
Source quote
L290: CSN [Ours] │ ×3 │ {\textcolor[rgb]{1,0,0}{35.87 / 0.9693}} │ {\textcolor[rgb]{1,0,0}{33.53 / 0.9464}} │ {\textcolor[rgb]{1,0,0}{34.64 / 0.9647}} │ {\textcolor[rgb]{1,0,0}{36.09 / 0.9697}} │ {\textcolor[rgb]{1,0,0}{33.68 / 0.9464}} │ {\textcolor[rgb]{1,0,0}{34.95 / 0.9653}}
2018CSN (C1) proposedPSNR32.28 dBsplit: test · scale=×4 · downsampling=k-space truncation · training-setup=C1 single-sliceChannel Splitting Network for Single MR Image Super-Resolution
Source quote
L301: CSN [Ours] │ ×4 │ {\textcolor[rgb]{1,0,0}{33.40 / 0.9486}} │ {\textcolor[rgb]{1,0,0}{31.23 / 0.9093}} │ {\textcolor[rgb]{1,0,0}{32.05 / 0.9413}} │ {\textcolor[rgb]{1,0,0}{33.51 / 0.9489}} │ {\textcolor[rgb]{1,0,0}{31.27 / 0.9092}} │ {\textcolor[rgb]{1,0,0}{32.28 / 0.9421}}
2018NDFlow: Centre proposedOverall class-balanced average accuracy0.9272Overall across the three London imaging centres; class-balanced average accuracy.Nonparametric Density Flows for MRI Intensity Normalisation
Source quote
L339: \MethodCentre │ 0.9687 │ 0.9081 │ 0.7945 │ 0.9272
2013Cross-sectional piecewise constant model (proposed approach) proposednumber of under-segmented voxels10.48%Reduction relative to Niethammer et al. [15], observed over all 18 tracts from 9 scans …A Cross-Sectional Piecewise Constant Model for Segmenting Highly Curved Fiber Tracts in Diffusion MR Images
Source quote
L114: Figure 3(b) shows the resulting DSC for all 18 cingulum segmentations. Note that our proposed approach performs better than the competing methods, even beating the average 0.615 DSC reported on comparable data for only two cingulum bundles in [2]. The piecewise constant approaches in [9, 11] failed to segment the cingulum. Instead, the segmentation leaked and delineated the corpus callosum seen in red in Figure 3(a). Meanwhile, the geodesic active contours approach of Feddern et al. [10] showed difficulty dealing with noisy edge information, leading to over-segmentation. The closest competing method to ours is that of Niethammer et al. [15], one sample of which is shown in Figure 3(c). Although the DSC values are somewhat comparable (Fig. 3(b)), the increased accuracy of our method was significant (p = 0.0298). Further, our approach showed consistent (i.e., over all 18 tracts) reduction in the amount of under-segmentation compared to [15]. This reduction, likely due to our use of a more localized image appearance model, was most pronounced around the genu and splenium (as highlighted by the blue arrows). Quantitatively, we observed a significant reduction of 10.48% in the number of under-segmented voxels (Niethammer et al. [15]: