IXI

45 papers · 131 extracted observations · image super resolution · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

29.933.336.740.1202220242025Cohf-T (Ours-L, final variant): 31.82 (2022)Cohf-T (Ours-L, final variant): 32.79 (2022)Cohf-T (Ours-L, final variant): 35.73 (2022)EqSim + Com + Adv: 36.73 (2022)DefSim + Com + Adv: 36.99 (2022)Blaze3DM: 38.86 (2024)Blaze3DM: 39.35 (2024)Deform-Mamba (Our): 30.6 (2024)I2I-Galip-M: 32.34 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 34 of 34 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026EvoML proposednormalized PSNR0.7859split: test · supervisedValidation-Gated ML Pipeline Synthesis with Expert-Grounded Self-Evolving Skills
Source quote
L976: on FastMRI against the next-best 0.8579 and 0.7859 on IXI
2025Tetrahedron-Net(TM-bspl) proposedDSC0.765split: test · unsupervised · decoder=DenseUNetTetrahedron-Net for Medical Image Registration
Source quote
L372: Tetrahedron-Net(TM-bspl) │ 0.765 │ <0.0001
2025TCIP proposedASSD↓0.470split: test · subset=58 volumes; 58×57 paired samples · resolution=58x57 · TCI-window-size=3TCIP: Threshold-Controlled Iterative Pyramid Network for Deformable Medical Image Registration
Source quote
L354: 1.229 │ 0.470 │ 0.230
2025TCIP proposedMSE (10 (-3))0.230split: test · subset=58 volumes; 58×57 paired samples · resolution=58x57 · TCI-window-size=3TCIP: Threshold-Controlled Iterative Pyramid Network for Deformable Medical Image Registration
Source quote
L354: 1.229 │ 0.470 │ 0.230
2024I2I-Galip-M proposedPSNR32.34split: test · regime=multi-domain · direction=T2-weighted-to-PDI2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIP
Source quote
L140: I2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20
2024I2I-Galip-M proposedSSIM95.74split: test · regime=multi-domain · direction=T2-weighted-to-PDI2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIP
Source quote
L140: I2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20
2024Blaze3DM proposedPSNR ↑39.35split: test · sampling=Poisson · acceleration=×8Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L245: Blaze3DM (Ours) │ 39.35
2024Blaze3DM proposedPSNR ↑38.86split: test · anisotropy=×4Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem Solving
Source quote
L246: 0.957 │ 0.952 │ 0.951 │ 38.86 │ 0.951 │ 0.949 │ 0.949
2024Deform-Mamba (Our) proposedPSNR30.60split: test · scale=4×Deform-Mamba Network for MRI Super-Resolution
Source quote
L180: Our │ 32.11 │ 0.7194 │ 30.60 │ 0.8965
2024UA-MT proposedDSC0.04split: test · semi-supervised · comparison=U-Net · labeled-samples=1Guidelines for Cerebrovascular Segmentation: Managing Imperfect Annotations in the context of Semi-Supervised Learning
Source quote
L374: For example the improvement in the DSC between UA-MT and U-Net when using 1 labeled sample is 0.04 but it decreases to 0.009 when using 9 labeled samples on IXI dataset. Qualitative results confirm these findings (see Figs. \ref{fig:visual_results_xp1_Bullitt} and \ref{fig:visual_results_xp1_IXI}). In addition, we can observe that the segmentations generated by the supervised U-Net exhibit significant noise, as confirmed by the higher standard deviations, particularly when only one sample is used for training. This noise is typically attributed to an overfitting problem.
2024UA-MT proposedDSC0.009split: test · semi-supervised · comparison=U-Net · labeled-samples=9Guidelines for Cerebrovascular Segmentation: Managing Imperfect Annotations in the context of Semi-Supervised Learning
Source quote
L374: For example the improvement in the DSC between UA-MT and U-Net when using 1 labeled sample is 0.04 but it decreases to 0.009 when using 9 labeled samples on IXI dataset. Qualitative results confirm these findings (see Figs. \ref{fig:visual_results_xp1_Bullitt} and \ref{fig:visual_results_xp1_IXI}). In addition, we can observe that the segmentations generated by the supervised U-Net exhibit significant noise, as confirmed by the higher standard deviations, particularly when only one sample is used for training. This noise is typically attributed to an overfitting problem.
2023TransMRSR proposedPSNR30.85 dBsplit: test · scale=×8 · modality=T1wTransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-Resolution
Source quote
L142: TransMRSR │ \color{red}38.56 │ \color{red}0.9862 │ \color{red}30.85 │ \color{red}0.9451 │ \color{red}36.98 │ \color{red}0.9793 │ \color{red}30.32 │ \color{red}0.9353
2023TransMRSR proposedSSIM0.9451split: test · scale=×8 · modality=T1wTransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-Resolution
Source quote
L142: TransMRSR │ \color{red}38.56 │ \color{red}0.9862 │ \color{red}30.85 │ \color{red}0.9451 │ \color{red}36.98 │ \color{red}0.9793 │ \color{red}30.32 │ \color{red}0.9353
2023Conformal (MCCQR with conformal prediction) proposedMAD4.40split: test · training-data=NAKO normative sample (N=10,691)From Group-Differences to Single-Subject Probability: Conformal Prediction-based Uncertainty Estimation for Brain-Age Modeling
Source quote
L118: MAD of 4.40, in the MDD sample of the MACS a MAD of 3.71 and in the BiDirect our model obtains a
2023Proposed method with quadratic age model proposedMAE4.36 yearssplit: test · subjects=562 · age-model=quadratic · validation=nested 5-fold cross-validation · age-discretization=20 intervalsA lightweight generative model for interpretable subject-level prediction
Source quote
L2242: 4.36
2022EqSim + Com + Adv proposedPSNR36.73split: test · pairing=non-aligned · modality=T2-to-PD · resolution=64x64 · training_patch=64×64×64 · data_generation=semi-synthetic deformationsDeformation equivariant cross-modality image synthesis with paired non-aligned training data
Source quote
L400: EqSim + Com + Adv │ 36.73 │ 0.9557 │ 1.183 │ 0.6975
2022DefSim + Com + Adv proposedPSNR36.99split: test · pairing=non-aligned · modality=T2-to-PD · resolution=64x64 · training_patch=64×64×64 · data_generation=semi-synthetic deformationsDeformation equivariant cross-modality image synthesis with paired non-aligned training data
Source quote
L401: DefSim + Com + Adv │ 36.99 │ 0.9573 │ 1.181 │ 0.6671
2022LKU-Net-4,5 proposedDice score0.752split: test · registration-type=non-diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from
2022LKU-Net-8,5 proposedDice score0.757split: test · registration-type=non-diffeomorphic · first-layer-kernels=8 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022LKU-Net-diff-4,5 proposedDice score0.746split: test · registration-type=diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022MMT (random-missing model) proposedPSNR40.69 dBsplit: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022MMT (random-missing model) proposedSSIM0.977split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022MMT (random-missing model) proposedLPIPS0.069split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022Cohf-T (Ours-L, final variant) proposedPSNR35.73split: test · modality=T2WI · upsampling=2×Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
Source quote
L215: Ours-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129
2022Cohf-T (Ours-L, final variant) proposedPSNR32.79split: test · modality=T2WI · upsampling=3×Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
Source quote
L215: Ours-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129
2022Cohf-T (Ours-L, final variant) proposedPSNR31.82split: test · modality=T2WI · upsampling=4×Cross-Modality High-Frequency Transformer for MR Image Super-Resolution
Source quote
L215: Ours-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129
2021TTM+PC-RNN proposedPSNR0.64 dBsplit: test · acceleration=4× · reference-matching=mutual informationReference-based Magnetic Resonance Image Reconstruction Using Texture Transforme
Source quote
L113: From Table~\ref{tab1}, we can make the following observations: (i) Naively treating the reference image as an additional input cannot improve the reconstruction performance. Due to lacking an efficient mechanism of searching and transferring the texture information in reference images, it results in slightly lower performance across four different methods. (ii) By using the proposed TTM, we are able to achieve obvious improvements as compared to models that naively use the reference images and the original models. (iii) The gain in performance achieved by TTM are consistent across different reconstruction methods, as shown in Fig.~\ref{fig4}. Even for the state-of-the-art CRNN method (i.e. PC-RNN~\cite{pcrnn}), the proposed TTM still can improve the reconstruction quality by 0.64 dB in term of PSNR. Fig.~\ref{fig3} shows the
2021CSC\ell_4Net proposedPSNR36.45 dBsplit: test · training=unsupervised-unpaired · translation=T2-w-to-PD-w · test_samples=100Brain Image Synthesis With Unsupervised Multivariate Canonical CSCl4Net
Source quote
L176: PSNR (dB) │ 30.49 │ 32.53 │ 32.66 │ 32.75 │ 33.11 │ 36.45
2020HLH-GAN (SRI) proposedPSNR32.04 dBsplit: test · variant=simultaneous super-resolution and inpainting · modality=T2-weighted MRISuper-Resolution and Inpainting with Degraded and Upgraded Generative Adversarial Networks
Source quote
L558: 32.04
2020HLH-GAN (SR+I) proposedPSNR28.59 dBsplit: test · variant=super-resolution followed by inpainting · modality=T2-weighted MRISuper-Resolution and Inpainting with Degraded and Upgraded Generative Adversarial Networks
Source quote
L560: 28.59
2020HLH-GAN (I+SR) proposedPSNR28.32 dBsplit: test · variant=inpainting followed by super-resolution · modality=T2-weighted MRISuper-Resolution and Inpainting with Degraded and Upgraded Generative Adversarial Networks
Source quote
L562: 28.32
2018CSN (C1) proposedPSNR41.28 dBsplit: test · scale=×2 · downsampling=bicubic · training-setup=C1 single-sliceChannel Splitting Network for Single MR Image Super-Resolution
Source quote
L279: CSN [Ours] │ ×2 │ {\textcolor[rgb]{1,0,0}{41.28 / 0.9895}} │ {\textcolor[rgb]{1,0,0}{38.27 / 0.9810}} │ {\textcolor[rgb]{1,0,0}{39.71 / 0.9863}} │ {\textcolor[rgb]{1,0,0}{41.77 / 0.9897}} │ {\textcolor[rgb]{1,0,0}{38.62 / 0.9813}} │ {\textcolor[rgb]{1,0,0}{40.47 / 0.9868}}
2018CSN (C1) proposedPSNR33.68 dBsplit: test · scale=×3 · downsampling=k-space truncation · training-setup=C1 single-sliceChannel Splitting Network for Single MR Image Super-Resolution
Source quote
L290: CSN [Ours] │ ×3 │ {\textcolor[rgb]{1,0,0}{35.87 / 0.9693}} │ {\textcolor[rgb]{1,0,0}{33.53 / 0.9464}} │ {\textcolor[rgb]{1,0,0}{34.64 / 0.9647}} │ {\textcolor[rgb]{1,0,0}{36.09 / 0.9697}} │ {\textcolor[rgb]{1,0,0}{33.68 / 0.9464}} │ {\textcolor[rgb]{1,0,0}{34.95 / 0.9653}}
2018CSN (C1) proposedPSNR32.28 dBsplit: test · scale=×4 · downsampling=k-space truncation · training-setup=C1 single-sliceChannel Splitting Network for Single MR Image Super-Resolution
Source quote
L301: CSN [Ours] │ ×4 │ {\textcolor[rgb]{1,0,0}{33.40 / 0.9486}} │ {\textcolor[rgb]{1,0,0}{31.23 / 0.9093}} │ {\textcolor[rgb]{1,0,0}{32.05 / 0.9413}} │ {\textcolor[rgb]{1,0,0}{33.51 / 0.9489}} │ {\textcolor[rgb]{1,0,0}{31.27 / 0.9092}} │ {\textcolor[rgb]{1,0,0}{32.28 / 0.9421}}