IXI
45 papers · 131 extracted observations · image super resolution · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Blaze3DM SOTA frontier (+1 variant) | 39.35 | 2024-05-01 | sampling=Poisson · acceleration=×8 · Compressed-sensing MRI reconstruction; ×8 acceleration Poisson sub-sampling on the IX… | Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem SolvingSource quoteBlaze3DM (Ours) │ 39.35 |
| 2 | DefSim + Com + Adv SOTA frontier (+1 variant) | 36.99 | 2022-08-01 | pairing=non-aligned · modality=T2-to-PD · resolution=64x64 · training_patch=64×64×64 · data_generation=semi-synthetic deformations · Semi-synthetic 3D IXI task with simulated deformations added to PD images; 192 traini… | Deformation equivariant cross-modality image synthesis with paired non-aligned training dataSource quoteDefSim + Com + Adv │ 36.99 │ 0.9573 │ 1.181 │ 0.6671 |
| 3 | Cohf-T (Ours-L, final variant) SOTA frontier (+2 variants) | 35.73 | 2022-03-01 | modality=T2WI · upsampling=2× · T2WI super-resolution at 2× upsampling; test split; Ours-L is the final variant with … | Cross-Modality High-Frequency Transformer for MR Image Super-ResolutionSource quoteOurs-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129 |
| 4 | I2I-Galip-M | 32.34 | 2025-01-01 | regime=multi-domain · direction=T2-weighted-to-PD · Multi-domain IXI brain MRI; T2-weighted→PD translation, using one network across task… | I2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIPSource quoteI2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20 |
| 5 | Deform-Mamba (Our) | 30.6 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (92 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
Regimesemi-supervised (4)unsupervised (2)fixed-budget-training-1-000-case-lower-risk-selection (1)lowest-risk-25-retention (1)fixed-budget-training-1-000-case-random-selection (1)supervised (1)
Showing 21 of 21 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | PAS-Mamba proposed | SSIM | 0.9805 | Radial undersampling, ×2 acceleration. | PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI ReconstructionSource quoteL293: In our experiments, PAS-Mamba consistently achieved the best performance across different datasets and undersampling masks. Notably, under the IXI radial ×2 setting, it achieves a PSNR of 40.43 dB and an SSIM of 0.9805. Unlike most existing methods that treat the frequency domain as a unified representation, PAS-Mamba explicitly decouples phase and amplitude modeling, which better aligns with the intrinsic characteristics of k-space. Moreover, by combining Mamba-based global dependency modeling in the frequency domain with locality-preserving LocalMamba in the image domain, PAS-Mamba effectively balances global structure recovery and local detail preservation. In addition, the proposed Dual-Domain Complementary Fusion Module (DDCFM) enables more effective integration of spatial- and frequency-domain features, reducing feature interference and further improving reconstruction quality. Beyond these general trends, the superior performance of PAS-Mamba can be attributed to its key design choices. |
| 2025 | MDPG proposed | SSIM | 0.833 | split: val · acceleration=8× · sampling-rate=0.04c | MDPG: Multi-domain Diffusion Prior Guidance for MRI ReconstructionSource quoteL132: MDPG (ours) │ 27.50 │ 0.833 │ 0.0278 │ 31.00 │ 0.914 │ 0.0124 |
| 2025 | HealthGPT-M3 proposed | SSIM | 78.19 | 4× super-resolution. | HealthGPT: A Medical Large Vision-Language Model for Unifying Comprehension and Generation via Heterogeneous Knowledge AdaptationSource quoteL304: In contrast, our method significantly mitigates this issue. Specifically, \texttt{HealthGPT-M3} excels in key metrics such as SSIM, PSNR, and ISE, achieving scores of 78.19, 32.76, and 34.47, respectively. |
| 2025 | ISTA-Net baseline | SSIM | 0.829 | split: val · acceleration=8× · sampling-rate=0.04c | MDPG: Multi-domain Diffusion Prior Guidance for MRI ReconstructionSource quoteL123: ISTA-Net \cite{ista} │ \secondbest{26.97} │ \secondbest{0.829} │ \secondbest{0.0313} │ 32.37 │ 0.942 │ 0.00915 |
| 2024 | pixel2pixel with AGI-Net proposed | SSIM | 96.62 | framework=pixel2pixel · modalities=T1,T2-to-PD | Cross Group Attention and Group-wise Rolling for Multimodal Medical Image SynthesisSource quoteL192: \cellcolor[HTML]{D3EAF8}AGI-Net │ \cellcolor[HTML]{D3EAF8}34.96 │ \cellcolor[HTML]{D3EAF8}96.62 |
| 2024 | I2I-Galip-M proposed | SSIM | 95.74 | split: test · regime=multi-domain · direction=T2-weighted-to-PD | I2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIPSource quoteL140: I2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20 |
| 2024 | Base+ISS2D+SPL (SMamba-UNet) proposed | SSIM | 0.9355 | upsampling=2× | Self-Prior Guided Mamba-UNet Networks for Medical Image Super-ResolutionSource quoteL189: Base+ISS2D+SPL (SMamba-UNet) │ \ding{51} │ \ding{51} │ \ding{51} │ 33.36 │ 0.9355 |
| 2024 | Single-Modality ablation | SSIM | 0.975 | ×4 random acceleration mask; multi-contrast fusion ablation | Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI ReconstructionSource quoteL810: 0.975 |
| 2024 | Multi-Modality ablation | SSIM | 0.985 | ×4 random acceleration mask; multi-contrast fusion ablation | Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI ReconstructionSource quoteL813: 0.985 |
| 2024 | Modality decoupling (CDLB) ablation | SSIM | 0.988 | ×4 random acceleration mask; multi-contrast fusion ablation | Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI ReconstructionSource quoteL816: 0.988 |
| 2024 | Base ablation | SSIM | 0.9245 | upsampling=2× | Self-Prior Guided Mamba-UNet Networks for Medical Image Super-ResolutionSource quoteL187: Base │ \ding{51} │ \ding{55} │ \ding{55} │ 33.18 │ 0.9245 |
| 2024 | pixel2pixel with ResUnet baseline | SSIM | 96.34 | backbone=ResUnet · framework=pixel2pixel · modalities=T1,T2-to-PD | Cross Group Attention and Group-wise Rolling for Multimodal Medical Image SynthesisSource quoteL191: \multirow{2}{*}{pixel2pixel} │ ResUnet │ 34.38 │ 96.34 |
| 2024 | CycleGAN baseline | SSIM | 93.68 | split: test · direction=T2-weighted-to-PD | I2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIPSource quoteL142: CycleGAN │ 26.10 \vert 87.36 │ 26.31 \vert 88.51 │ 27.43 \vert 93.68 │ 31.07 \vert 93.81 │ 24.56 \vert 88.26 │ 25.91 \vert 89.47 |
| 2023 | TransMRSR proposed | SSIM | 0.9451 | split: test · scale=×8 · modality=T1w | TransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-ResolutionSource quoteL142: TransMRSR │ \color{red}38.56 │ \color{red}0.9862 │ \color{red}30.85 │ \color{red}0.9451 │ \color{red}36.98 │ \color{red}0.9793 │ \color{red}30.32 │ \color{red}0.9353 |
| 2023 | Restormer baseline | SSIM | 0.9436 | split: test · scale=×8 · modality=T1w | TransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-ResolutionSource quoteL140: Restormer │ 37.52 │ 0.9834 │ 30.35 │ \textcolor{blue}{0.9436} │ 35.80 │ 0.9745 │ 29.31 │ 0.9265 |
| 2022 | MMT (random-missing model) proposed | SSIM | 0.977 | split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2 | One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data ImputationSource quoteL299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069 |
| 2022 | MMGAN (random-missing model) baseline | SSIM | 0.975 | split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2 | One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data ImputationSource quoteL283: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 39.76/0.975/0.094 |
| 2021 | UGAC proposed | SSIM | 0.83 | pairing=unpaired · test-subset=patients aged ≥45 · translation=T1w-to-T2w · training-subset=patients aged <45 | Uncertainty-aware Generalized Adaptive CycleGANSource quoteL391: Table~\ref{tab:abl2} shows the performance of all the models when trained and evaluated on different splits. Zooming into the young \rightarrow old experiments, where the model is trained on ``young'' patients and evaluated on ``old'' patients, our model has an SSIM and PSNR of 0.83 and 25.8, respectively, compared to that of 0.71 and 19.4 for the best performing baseline. We see a similar trend for the other split training on lighter patients and evaluating on heavier patients (see Table~\ref{tab:abl2}-Col 3). |
| 2021 | MANet | SSIM | 0.969 | T2-weighted reconstruction guided by T1; 1D Random undersampling, 3× acceleration. | Multi-modal Aggregation Network for Fast MR ImagingSource quoteL210: Therefore, its performance is less effective in comparison with other fusion models. In particular, under the 1D Random sampling mask with 3× acceleration, we improve the PSNR from 33.929 dB to 36.927 dB, and SSIM from 0.945 to 0.969, as compared to current best approach, \ie, DuDoRNet. Since DuDoRNet and Xiang et al. only use the auxiliary modality as prior information, without any changes in the network, they have fewer parameters than our method. However, their reconstruction results are inferior to those produced by our model. Under 2D Radial undersampling patterns, our MANet achieves scores 34.317 and 32.872 in terms of PSNR at 6× and 9× acceleration rates, respectively. |
| 2021 | DuDoRNet | SSIM | 0.945 | T2-weighted reconstruction; 1D Random undersampling, 3× acceleration. Named as the comp… | Multi-modal Aggregation Network for Fast MR ImagingSource quoteL210: Therefore, its performance is less effective in comparison with other fusion models. In particular, under the 1D Random sampling mask with 3× acceleration, we improve the PSNR from 33.929 dB to 36.927 dB, and SSIM from 0.945 to 0.969, as compared to current best approach, \ie, DuDoRNet. Since DuDoRNet and Xiang et al. only use the auxiliary modality as prior information, without any changes in the network, they have fewer parameters than our method. However, their reconstruction results are inferior to those produced by our model. Under 2D Radial undersampling patterns, our MANet achieves scores 34.317 and 32.872 in terms of PSNR at 6× and 9× acceleration rates, respectively. |
| 2021 | Best-performing baseline baseline | SSIM | 0.71 | pairing=unpaired · test-subset=patients aged ≥45 · translation=T1w-to-T2w · training-subset=patients aged <45 | Uncertainty-aware Generalized Adaptive CycleGANSource quoteL391: Table~\ref{tab:abl2} shows the performance of all the models when trained and evaluated on different splits. Zooming into the young \rightarrow old experiments, where the model is trained on ``young'' patients and evaluated on ``old'' patients, our model has an SSIM and PSNR of 0.83 and 25.8, respectively, compared to that of 0.71 and 19.4 for the best performing baseline. We see a similar trend for the other split training on lighter patients and evaluating on heavier patients (see Table~\ref{tab:abl2}-Col 3). |