IXI

45 papers · 131 extracted observations · image super resolution · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

29.933.336.740.1202220242025Cohf-T (Ours-L, final variant): 31.82 (2022)Cohf-T (Ours-L, final variant): 32.79 (2022)Cohf-T (Ours-L, final variant): 35.73 (2022)EqSim + Com + Adv: 36.73 (2022)DefSim + Com + Adv: 36.99 (2022)Blaze3DM: 38.86 (2024)Blaze3DM: 39.35 (2024)Deform-Mamba (Our): 30.6 (2024)I2I-Galip-M: 32.34 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 21 of 21 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026PAS-Mamba proposedSSIM0.9805Radial undersampling, ×2 acceleration.PAS-Mamba: Phase-Amplitude-Spatial State Space Model for MRI Reconstruction
Source quote
L293: In our experiments, PAS-Mamba consistently achieved the best performance across different datasets and undersampling masks. Notably, under the IXI radial ×2 setting, it achieves a PSNR of 40.43 dB and an SSIM of 0.9805. Unlike most existing methods that treat the frequency domain as a unified representation, PAS-Mamba explicitly decouples phase and amplitude modeling, which better aligns with the intrinsic characteristics of k-space. Moreover, by combining Mamba-based global dependency modeling in the frequency domain with locality-preserving LocalMamba in the image domain, PAS-Mamba effectively balances global structure recovery and local detail preservation. In addition, the proposed Dual-Domain Complementary Fusion Module (DDCFM) enables more effective integration of spatial- and frequency-domain features, reducing feature interference and further improving reconstruction quality. Beyond these general trends, the superior performance of PAS-Mamba can be attributed to its key design choices.
2025MDPG proposedSSIM0.833split: val · acceleration=8× · sampling-rate=0.04cMDPG: Multi-domain Diffusion Prior Guidance for MRI Reconstruction
Source quote
L132: MDPG (ours) │ 27.50 │ 0.833 │ 0.0278 │ 31.00 │ 0.914 │ 0.0124
2025HealthGPT-M3 proposedSSIM78.194× super-resolution.HealthGPT: A Medical Large Vision-Language Model for Unifying Comprehension and Generation via Heterogeneous Knowledge Adaptation
Source quote
L304: In contrast, our method significantly mitigates this issue. Specifically, \texttt{HealthGPT-M3} excels in key metrics such as SSIM, PSNR, and ISE, achieving scores of 78.19, 32.76, and 34.47, respectively.
2025ISTA-Net baselineSSIM0.829split: val · acceleration=8× · sampling-rate=0.04cMDPG: Multi-domain Diffusion Prior Guidance for MRI Reconstruction
Source quote
L123: ISTA-Net \cite{ista} │ \secondbest{26.97} │ \secondbest{0.829} │ \secondbest{0.0313} │ 32.37 │ 0.942 │ 0.00915
2024pixel2pixel with AGI-Net proposedSSIM96.62framework=pixel2pixel · modalities=T1,T2-to-PDCross Group Attention and Group-wise Rolling for Multimodal Medical Image Synthesis
Source quote
L192: \cellcolor[HTML]{D3EAF8}AGI-Net │ \cellcolor[HTML]{D3EAF8}34.96 │ \cellcolor[HTML]{D3EAF8}96.62
2024I2I-Galip-M proposedSSIM95.74split: test · regime=multi-domain · direction=T2-weighted-to-PDI2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIP
Source quote
L140: I2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20
2024Base+ISS2D+SPL (SMamba-UNet) proposedSSIM0.9355upsampling=2×Self-Prior Guided Mamba-UNet Networks for Medical Image Super-Resolution
Source quote
L189: Base+ISS2D+SPL (SMamba-UNet) │ \ding{51} │ \ding{51} │ \ding{51} │ 33.36 │ 0.9355
2024Single-Modality ablationSSIM0.975×4 random acceleration mask; multi-contrast fusion ablationNull Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction
Source quote
L810: 0.975
2024Multi-Modality ablationSSIM0.985×4 random acceleration mask; multi-contrast fusion ablationNull Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction
Source quote
L813: 0.985
2024Modality decoupling (CDLB) ablationSSIM0.988×4 random acceleration mask; multi-contrast fusion ablationNull Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction
Source quote
L816: 0.988
2024Base ablationSSIM0.9245upsampling=2×Self-Prior Guided Mamba-UNet Networks for Medical Image Super-Resolution
Source quote
L187: Base │ \ding{51} │ \ding{55} │ \ding{55} │ 33.18 │ 0.9245
2024pixel2pixel with ResUnet baselineSSIM96.34backbone=ResUnet · framework=pixel2pixel · modalities=T1,T2-to-PDCross Group Attention and Group-wise Rolling for Multimodal Medical Image Synthesis
Source quote
L191: \multirow{2}{*}{pixel2pixel} │ ResUnet │ 34.38 │ 96.34
2024CycleGAN baselineSSIM93.68split: test · direction=T2-weighted-to-PDI2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIP
Source quote
L142: CycleGAN │ 26.10 \vert 87.36 │ 26.31 \vert 88.51 │ 27.43 \vert 93.68 │ 31.07 \vert 93.81 │ 24.56 \vert 88.26 │ 25.91 \vert 89.47
2023TransMRSR proposedSSIM0.9451split: test · scale=×8 · modality=T1wTransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-Resolution
Source quote
L142: TransMRSR │ \color{red}38.56 │ \color{red}0.9862 │ \color{red}30.85 │ \color{red}0.9451 │ \color{red}36.98 │ \color{red}0.9793 │ \color{red}30.32 │ \color{red}0.9353
2023Restormer baselineSSIM0.9436split: test · scale=×8 · modality=T1wTransMRSR: Transformer-based Self-Distilled Generative Prior for Brain MRI Super-Resolution
Source quote
L140: Restormer │ 37.52 │ 0.9834 │ 30.35 │ \textcolor{blue}{0.9436} │ 35.80 │ 0.9745 │ 29.31 │ 0.9265
2022MMT (random-missing model) proposedSSIM0.977split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L299: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 40.69/0.977/0.069
2022MMGAN (random-missing model) baselineSSIM0.975split: test · model-variant=random-missing · target-modality=PD · input-modalities=T1+T2One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation
Source quote
L283: \multicolumn{1}{|c|}{\ding{51}} │ \multicolumn{1}{c|}{\ding{51}} │ \ding{55} │ \multicolumn{1}{c|}{-} │ \multicolumn{1}{c|}{-} │ 39.76/0.975/0.094
2021UGAC proposedSSIM0.83pairing=unpaired · test-subset=patients aged ≥45 · translation=T1w-to-T2w · training-subset=patients aged <45Uncertainty-aware Generalized Adaptive CycleGAN
Source quote
L391: Table~\ref{tab:abl2} shows the performance of all the models when trained and evaluated on different splits. Zooming into the young \rightarrow old experiments, where the model is trained on ``young'' patients and evaluated on ``old'' patients, our model has an SSIM and PSNR of 0.83 and 25.8, respectively, compared to that of 0.71 and 19.4 for the best performing baseline. We see a similar trend for the other split training on lighter patients and evaluating on heavier patients (see Table~\ref{tab:abl2}-Col 3).
2021MANetSSIM0.969T2-weighted reconstruction guided by T1; 1D Random undersampling, 3× acceleration.Multi-modal Aggregation Network for Fast MR Imaging
Source quote
L210: Therefore, its performance is less effective in comparison with other fusion models. In particular, under the 1D Random sampling mask with 3× acceleration, we improve the PSNR from 33.929 dB to 36.927 dB, and SSIM from 0.945 to 0.969, as compared to current best approach, \ie, DuDoRNet. Since DuDoRNet and Xiang et al. only use the auxiliary modality as prior information, without any changes in the network, they have fewer parameters than our method. However, their reconstruction results are inferior to those produced by our model. Under 2D Radial undersampling patterns, our MANet achieves scores 34.317 and 32.872 in terms of PSNR at 6× and 9× acceleration rates, respectively.
2021DuDoRNetSSIM0.945T2-weighted reconstruction; 1D Random undersampling, 3× acceleration. Named as the comp…Multi-modal Aggregation Network for Fast MR Imaging
Source quote
L210: Therefore, its performance is less effective in comparison with other fusion models. In particular, under the 1D Random sampling mask with 3× acceleration, we improve the PSNR from 33.929 dB to 36.927 dB, and SSIM from 0.945 to 0.969, as compared to current best approach, \ie, DuDoRNet. Since DuDoRNet and Xiang et al. only use the auxiliary modality as prior information, without any changes in the network, they have fewer parameters than our method. However, their reconstruction results are inferior to those produced by our model. Under 2D Radial undersampling patterns, our MANet achieves scores 34.317 and 32.872 in terms of PSNR at 6× and 9× acceleration rates, respectively.
2021Best-performing baseline baselineSSIM0.71pairing=unpaired · test-subset=patients aged ≥45 · translation=T1w-to-T2w · training-subset=patients aged <45Uncertainty-aware Generalized Adaptive CycleGAN
Source quote
L391: Table~\ref{tab:abl2} shows the performance of all the models when trained and evaluated on different splits. Zooming into the young \rightarrow old experiments, where the model is trained on ``young'' patients and evaluated on ``old'' patients, our model has an SSIM and PSNR of 0.83 and 25.8, respectively, compared to that of 0.71 and 19.4 for the best performing baseline. We see a similar trend for the other split training on lighter patients and evaluating on heavier patients (see Table~\ref{tab:abl2}-Col 3).