29.933.336.740.1202220242025Cohf-T (Ours-L, final variant): 31.82 (2022)Cohf-T (Ours-L, final variant): 32.79 (2022)Cohf-T (Ours-L, final variant): 35.73 (2022)EqSim + Com + Adv: 36.73 (2022)DefSim + Com + Adv: 36.99 (2022)Blaze3DM: 38.86 (2024)Blaze3DM: 39.35 (2024)Deform-Mamba (Our): 30.6 (2024)I2I-Galip-M: 32.34 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024UVI-Net data augmentation (Ours (w/o inst opt.)) ablationDice score0.818split: test · training-subset=20 samples · augmentation-scale=10× · segmentation-models=3-model average · training-iterations=15000Data-Efficient Unsupervised Interpolation Without Any Intermediate Frame for 4D Medical Images
Source quote
L342: Ours (w/o inst opt.) │ 0.843 │ 0.818 │ 0.831
2024EfficientMorph (C=24) ablationDice score0.7317epochs=100 · embedding-dimension=C=24EFFICIENTMORPH: Parameter-Efficient Transformer-Based Architecture for 3D Image Registration
Source quote
L380: Table \ref{tab:IXI:Results} presents the performance results on the IXI dataset. Notably, ablation experiments reducing the embedding dimensions (C=24) showed an improvement in performance from 0.7317, surpassing TransMorph's 0.7293 at 100 epochs. This also brought the model's accuracy in line with Fourier-Net-s while offering superior inference speed compared to all baselines. While extended training beyond 100 epochs could potentially result in even higher accuracy, this is left for future work.
2024VM baselineDice score0.813split: test · training-subset=20 samples · augmentation-scale=10× · segmentation-models=3-model average · training-iterations=15000Data-Efficient Unsupervised Interpolation Without Any Intermediate Frame for 4D Medical Images
Source quote
L337: VM~\cite{voxelmorph2019} │ 0.825 │ 0.813 │ 0.803
2024TransMorph baselineDice score0.7293epochs=100EFFICIENTMORPH: Parameter-Efficient Transformer-Based Architecture for 3D Image Registration
Source quote
L380: Table \ref{tab:IXI:Results} presents the performance results on the IXI dataset. Notably, ablation experiments reducing the embedding dimensions (C=24) showed an improvement in performance from 0.7317, surpassing TransMorph's 0.7293 at 100 epochs. This also brought the model's accuracy in line with Fourier-Net-s while offering superior inference speed compared to all baselines. While extended training beyond 100 epochs could potentially result in even higher accuracy, this is left for future work.
2022LKU-Net-4,5 proposedDice score0.752split: test · registration-type=non-diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from
2022LKU-Net-8,5 proposedDice score0.757split: test · registration-type=non-diffeomorphic · first-layer-kernels=8 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022LKU-Net-diff-4,5 proposedDice score0.746split: test · registration-type=diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022U-Net_4 baselineDice score0.727split: test · registration-type=non-diffeomorphicU-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from
2022TransMorph baselineDice score0.746split: test · registration-type=non-diffeomorphicU-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from
2022TransMorph-diff baselineDice score0.599split: test · registration-type=diffeomorphicU-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).