IXI

45 papers · 131 extracted observations · image super resolution · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

29.933.336.740.1202220242025Cohf-T (Ours-L, final variant): 31.82 (2022)Cohf-T (Ours-L, final variant): 32.79 (2022)Cohf-T (Ours-L, final variant): 35.73 (2022)EqSim + Com + Adv: 36.73 (2022)DefSim + Com + Adv: 36.99 (2022)Blaze3DM: 38.86 (2024)Blaze3DM: 39.35 (2024)Deform-Mamba (Our): 30.6 (2024)I2I-Galip-M: 32.34 (2025)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 3 of 3 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2022LKU-Net-4,5 proposedDice score0.752split: test · registration-type=non-diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from
2022LKU-Net-8,5 proposedDice score0.757split: test · registration-type=non-diffeomorphic · first-layer-kernels=8 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).
2022LKU-Net-diff-4,5 proposedDice score0.746split: test · registration-type=diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?
Source quote
L123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752).