IXI
45 papers · 131 extracted observations · image super resolution · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=test.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Blaze3DM SOTA frontier (+1 variant) | 39.35 | 2024-05-01 | sampling=Poisson · acceleration=×8 · Compressed-sensing MRI reconstruction; ×8 acceleration Poisson sub-sampling on the IX… | Blaze3DM: Marry Triplane Representation with Diffusion for 3D Medical Inverse Problem SolvingSource quoteBlaze3DM (Ours) │ 39.35 |
| 2 | DefSim + Com + Adv SOTA frontier (+1 variant) | 36.99 | 2022-08-01 | pairing=non-aligned · modality=T2-to-PD · resolution=64x64 · training_patch=64×64×64 · data_generation=semi-synthetic deformations · Semi-synthetic 3D IXI task with simulated deformations added to PD images; 192 traini… | Deformation equivariant cross-modality image synthesis with paired non-aligned training dataSource quoteDefSim + Com + Adv │ 36.99 │ 0.9573 │ 1.181 │ 0.6671 |
| 3 | Cohf-T (Ours-L, final variant) SOTA frontier (+2 variants) | 35.73 | 2022-03-01 | modality=T2WI · upsampling=2× · T2WI super-resolution at 2× upsampling; test split; Ours-L is the final variant with … | Cross-Modality High-Frequency Transformer for MR Image Super-ResolutionSource quoteOurs-L │ 36.85 │ 0.9739 │ 34.84 │ 0.9507 │ 33.26 │ 0.9425 │ 35.73 │ 0.9645 │ 32.79 │ 0.9498 │ 31.82 │ 0.9129 |
| 4 | I2I-Galip-M | 32.34 | 2025-01-01 | regime=multi-domain · direction=T2-weighted-to-PD · Multi-domain IXI brain MRI; T2-weighted→PD translation, using one network across task… | I2I-Galip: Unsupervised Medical Image Translation Using Generative Adversarial CLIPSource quoteI2I-Galip-M │ 27.22 \vert 90.18 │ 27.30 \vert 90.86 │ 32.34 \vert 95.74 │ 33.12 \vert 95.39 │ 26.76 \vert 90.75 │ 27.70 \vert 91.20 |
| 5 | Deform-Mamba (Our) | 30.6 | 2024-07-01 | scale=4× · 4× upsampling; held-out test split (92 subjects); low-resolution inputs synthesized i… | Deform-Mamba Network for MRI Super-ResolutionSource quoteOur │ 32.11 │ 0.7194 │ 30.60 │ 0.8965 |
Regimesemi-supervised (4)unsupervised (2)fixed-budget-training-1-000-case-lower-risk-selection (1)lowest-risk-25-retention (1)fixed-budget-training-1-000-case-random-selection (1)supervised (1)
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2022 | LKU-Net-4,5 proposed | Dice score | 0.752 | split: test · registration-type=non-diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5 | U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?Source quoteL122: In the case of non-diffeomorphic registration, U-Net_4 achieves 0.727 Dice score which is comparable with VoxelMorph-1 (0.723), VoxelMorph-2 (0.726), ViT-V-Net (0.728), CoTr (0.721), and PVT (0.729), but lower than those of nnFormer (0.740), TransMorph (0.746), and TransMorph-Bayes (0.746). However, LKU-Net-4,5 outperforms all other competing methods with a Dice score of 0.752. Note that the parameters and mult-adds of LKU-Net-4,5 are only 1.12% and 10.8% of those of TransMorph, respectively. Furthermore, by increasing the number channels from |
| 2022 | LKU-Net-8,5 proposed | Dice score | 0.757 | split: test · registration-type=non-diffeomorphic · first-layer-kernels=8 · LK-block-kernel-size=5 | U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?Source quoteL123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752). |
| 2022 | LKU-Net-diff-4,5 proposed | Dice score | 0.746 | split: test · registration-type=diffeomorphic · first-layer-kernels=4 · LK-block-kernel-size=5 | U-Net vs Transformer: Is U-Net Outdated in Medical Image Registration?Source quoteL123: from LKU-Net-4,5 to LKU-Net-8,5, a better Dice score of 0.757 can be achieved. The visual comparison of estimated deformations is given in Fig. \ref{fig:visual}. For diffeomorphic registration, U-Net-diff_4, LKU-Net-diff-4,5, and LKU-Net-diff-8,5 achieve Dice score of 0.744, 0.746, and 0.753, respectively. They all outperform TransMorph-diff (0.599) by a large margin and are comparable to TransMorph-bspl (0.752). |