ISIC2018
34 papers · 69 extracted observations · image classification · vision · Markdown · CSV · JSON API
Showing 6 of 6 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Conditional Point Sparsification (CPS) proposed | mIoU | 51.3 | 1-shot · backbone=DINOv2 ViT-L/14; SAM ViT-H | Boosting SAM for Cross-Domain Few-Shot Segmentation via Conditional Point SparsificationSource quoteL227: 51.3 │ 56.6 │ 70.0 │ 70.2 │ 46.0 │ 49.8 │ 42.8 │ 48.8 |
| 2026 | GF-SAM baseline | mIoU | 48.7 | 1-shot | Boosting SAM for Cross-Domain Few-Shot Segmentation via Conditional Point SparsificationSource quoteL225: GF-SAM │ 48.7 │ 55.2 │ 47.6 │ 47.4 │ 49.5 │ 57.7 │ 38.3 │ 42.9 |
| 2025 | Siamese-Diffusion (Random masks) proposed | mIoU | 1.64% | mask-type=random · segmentation-model=UNet | Noise-Consistent Siamese-Diffusion for Medical Image Synthesis and SegmentationSource quoteL284: Similar phenomena can be observed in \cref{tab3}. Interestingly, both UNet \cite{UNet} and SegFormer \cite{SegFormer} perform better with skin lesion images synthesized using random masks (i.e., ``Random") compared to those derived from real data (i.e., ``Real"). UNet achieves a remarkable increase of 1.52% in mDice and 1.64% in mIoU on ISIC2018, underscoring the sensitivity of segmentation to morphological diversity. \cref{tab4} presents segmentation performance comparisons using 1,000 Stain or Faeces samples synthesized with transformed masks (e.g., scaling), without real samples. Our method significantly outperforms AnomalyDiffusion \cite{Anomalydiffusion}, even surpassing results achieved with real faeces samples, highlighting its superior scalability. |
| 2023 | STM-UNet (ST block and ParallelConv enabled) proposed | mIoU | 0.7984 | split: test | STM-UNet: An Efficient U-shaped Architecture Based on Swin Transformer and Multi-scale MLP for Medical Image SegmentationSource quoteL189: 0.7984 |
| 2023 | Vanilla UNet with AS-MLP in bottleneck (ablation baseline) ablation | mIoU | 0.7720 | split: test | STM-UNet: An Efficient U-shaped Architecture Based on Swin Transformer and Multi-scale MLP for Medical Image SegmentationSource quoteL181: 0.7720 |
| 2022 | UNet baseline | mIoU | 77.86 | Comparative results on the ISIC2018 dataset; table reports benchmark metrics. | MALUNet: A Multi-Attention and Light-weight UNet for Skin Lesion SegmentationSource quoteL176: UNet\cite{unet} │ 7.77 │ 13.78 │ 77.86 │ 87.55 │ 94.05 │ 96.69 │ 85.86 |