ISIC2018
34 papers · 69 extracted observations · image classification · vision · Markdown · CSV · JSON API
Showing 8 of 8 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MaLViL proposed | DSC | 91.23% | MaLViL: Multi-axis Low-rank Vision-LSTM for Medical Image SegmentationSource quoteL324: 91.23 │ 96.75 | |
| 2024 | MSA^{\text{2}}Net proposed | DSC | 0.9129 | ISIC2018 benchmark; split and averaging are not stated. | MSA$^2$Net: Multi-scale Adaptive Attention-guided Network for Medical Image SegmentationSource quoteL137: MSA^{\text{2}}Net (Ours) │ \textcolor{blue}{0.9129} │ 0.8840 │ 0.9557 │ \textcolor{red}{0.9640} |
| 2024 | DermoSegDiff baseline | DSC | 0.9005 | ISIC2018 benchmark; split and averaging are not stated. | MSA$^2$Net: Multi-scale Adaptive Attention-guided Network for Medical Image SegmentationSource quoteL135: DermoSegDiff~\cite{bozorgpour2023dermosegdiff} │ \textcolor{red}{0.9005} │ 0.8761 │ 0.9811 │ 0.9587 |
| 2023 | Scale-aware super-resolution network with dual affinity learning (Our Method) proposed | DSC | 0.911 | split: test · resolution=320x320 · input-resolution=320×320 · target-resolution=640×640 | Scale-Aware Super-Resolution Network With Dual Affinity Learning for Lesion Segmentation From Medical ImagesSource quoteL280: Our Method │ 0.902 │ 0.829 │ \multicolumn{1}{c|}{0.013} │ 0.913 │ 0.848 │ \multicolumn{1}{c|}{0.049} │ 0.911 │ 0.844 │ 0.042 |
| 2022 | DAE-Former proposed | DSC | 0.9147 | Skin lesion segmentation task; experimental setup follows Azad et al. (2022), as stated… | DAE-Former: Dual Attention-guided Efficient Transformer for Medical Image SegmentationSource quoteL187: DAE-Former │ 0.9147 │ 0.9120 │ 0.9780 │ 0.9641 |
| 2022 | TMU-Net baseline | DSC | 0.9059 | Skin lesion segmentation task; experimental setup follows Azad et al. (2022), as stated… | DAE-Former: Dual Attention-guided Efficient Transformer for Medical Image SegmentationSource quoteL180: TMU-Net \cite{azad2022contextual} │ 0.9059 │ 0.9038 │ 0.9746 │ 0.9603 |
| 2022 | UNet baseline | DSC | 87.55 | Comparative results on the ISIC2018 dataset; table reports benchmark metrics. | MALUNet: A Multi-Attention and Light-weight UNet for Skin Lesion SegmentationSource quoteL176: UNet\cite{unet} │ 7.77 │ 13.78 │ 77.86 │ 87.55 │ 94.05 │ 96.69 │ 85.86 |
| 2021 | MCTrans proposed | DSC | 90.35 | Reported in the five-lesion-dataset comparison; the table does not specify a backbone o… | Multi-compound Transformer for Accurate Biomedical Image SegmentationSource quoteL267: MCTrans │ 92.30 │ 86.58 │ 83.69 │ 86.20 │ 90.35 |