GTSRB

179 papers · 356 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

46.064.082.0100.0201820222025MicronNet (fp16): 98.9 (2018)ℓ∞-based neuron pruning, threshold 6: 91.38 (2020)ℓ∞-based neuron pruning, threshold 7: 95.21 (2020)Context Agnostic (+ full; proposed full algorithm): 95.9 (2021)StolenEncoder with downstream classifier: 58.16 (2022)StolenEncoder with downstream classifier: 79.43 (2022)Dorm L=2: 91.32 (2023)Proposed method (stego DNN): 99.81 (2023)Short-CE: 50.0 (2023)Deep-CE: 67.0 (2023)Short-CE: 77.0 (2023)Deep-CE: 83.0 (2023)MExMI: 67.11 (2024)SwiftThief: 77.61 (2024)LaserGuider (final optimized; red trigger): 95.9 (2024)LaserGuider (final optimized; blue trigger): 96.0 (2024)LaserGuider (final optimized; green trigger): 96.3 (2024)CNN-large: 98.91 (2024)ResNet18: 99.18 (2024)CNN-STN: 99.43 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2023BaDExpert proposed non-standard sliceaverage ASR2.0split: val · runs=3 · attacks=average across 7BaDExpert: Extracting Backdoor Functionality for Accurate Backdoor Input Detection
Source quote
L603: Average │ 96.6 │ 98.2 │ 85.7 │ 47.4 │ 97.0 │ 14.1 │ 85.1 │ 97.5 │ 96.5 │ 23.2 │ 86.9 │ 47.6 │ 96.3 │ 98.2 │ 64.6 │ 12.8 │ 60.2 │ 46.7 │ 96.5 │ 2.0 \cr
2022AntidoteRT (25%) proposed non-standard slicePoisoned Repair Rate93.54%split: val · correction-threshold=customized · offline-poisoned-inputs=25%AntidoteRT: Run-time Detection and Correction of Poison Attacks on Neural Networks
Source quote
L266: Poisoned Repair Rate │ 85.76 │ 62.25 │ 93.54
2022NeuralCleanse (Groundtruth) baseline non-standard slicePoisoned Detection Rate86.49%split: valAntidoteRT: Run-time Detection and Correction of Poison Attacks on Neural Networks
Source quote
L285: \multirow{4}{*}{NeuralCleanse (Groundtruth)} │ Poisoned Detection Rate │ 83.35 │ 53.46 │ 86.49
2022NeuralCleanse (Groundtruth) baseline non-standard slicePoisoned Repair Rate16.87%split: valAntidoteRT: Run-time Detection and Correction of Poison Attacks on Neural Networks
Source quote
L286: Poisoned Repair Rate │ 90.29 │ 18.96 │ 16.87
2020Novel feature-based anomaly detection (no data augmentation) proposed non-standard sliceAttack success rate (Poison)69.6%split: val · case=e · data-augmentation=noneDetecting Backdoors in Neural Networks Using Novel Feature-Based Anomaly Detection
Source quote
L372: e) │ 93.61 │ 69.6 │ 93.61 │ 7.75
2020Novel feature-based anomaly detection (Gaussian-noise data augmentation) proposed non-standard sliceAttack success rate (Poison)7.75%split: val · case=e · data-augmentation=Gaussian noiseDetecting Backdoors in Neural Networks Using Novel Feature-Based Anomaly Detection
Source quote
L372: e) │ 93.61 │ 69.6 │ 93.61 │ 7.75
2020MinEnt + VAT + AMO ablationValidation accuracy on the target data42.8%split: val · adaptation=unsupervised-domain-adaptation · source_dataset=SynSignsTheoretical Analysis of Self-Training with Deep Networks on Unlabeled Data
Source quote
L886: MinEnt + VAT + AMO │ 20.6% │ 28.9% │ 83.2% │ 83.6% │ 42.8% │ 67.6%
2020Source Only baselineValidation accuracy on the target data77.8%split: val · adaptation=unsupervised-domain-adaptation · source_dataset=SynSignsTheoretical Analysis of Self-Training with Deep Networks on Unlabeled Data
Source quote
L885: Source Only │ 35.8% │ 57.3% │ 85.4% │ 86.3% │ 77.8% │ 58.7%
2017SBADA-GAN (batch size 32) proposedoverall accuracy96.7split: val · batch-size=32 · domain-adaptation=Synth Signs → GTSRBFrom Source to Target and Back: Symmetric Bi-Directional Adaptive GAN
Source quote
L756: when reducing it to 16 the overall accuracy remains almost unchanged (from 96.7 to 96.5).
2017SBADA-GAN (batch size 16) proposedoverall accuracy96.5split: val · batch-size=16 · domain-adaptation=Synth Signs → GTSRBFrom Source to Target and Back: Symmetric Bi-Directional Adaptive GAN
Source quote
L756: when reducing it to 16 the overall accuracy remains almost unchanged (from 96.7 to 96.5).