FreiHAND

54 papers · 140 extracted observations · hand mesh reconstruction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=test.

42.043.945.747.620232024CS-NVF: 42.4 (2023)CS-NVF: 47.2 (2023)HandDGP: 46.3 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 19 of 19 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
20263DB-H proposedPA-MPJPE5.5output=hand-decoderSAM 3D Body: Robust Full-Body Human Mesh Recovery
Source quote
L264: 3DB-H (Ours) │ 6.3 │ 5.5 │ 0.735 │ 0.988
20263DB-DINOv3 proposedPA-MPJPE5.5output=hand-decoder · variant=DINOv3SAM 3D Body: Robust Full-Body Human Mesh Recovery
Source quote
L265: 3DB-DINOv3 (Ours) │ 6.2 │ 5.5 │ 0.737 │ 0.988
2026HaMeR w/ AnyHand proposedPA-MPJPE5.54 mmparams=6.6MAnyHand: A Large-Scale Synthetic Dataset for RGB(-D) Hand Pose Estimation
Source quote
L317: The PA-MPJPE drops from 6.0\,mm to 5.54\,mm (a 7.6% reduction), and PA-MPVPE decreases from 5.7\,mm to 5.24\,mm (about 8.1%), lifting HaMeR into the same performance tier as the top-ranked approaches,
2025M3DHMR (ResNet34) proposedPA-MPJPE6.5mmsplit: test · backbone=ResNet34M3DHMR: Monocular 3D Hand Mesh Recovery
Source quote
L254: In Tab. \ref{tab4}, we compare our method with several state-of-the-art approaches on hand mesh recovery task using the FreiHAND dataset. Since the implementation of Stacked-ResNet in MobRecon is not available, we implement Stack-ResNet18 and fully reproduce the original results of MobRecon. Considering that Stack-ResNet34 can be achieved by adjusting hyperparameters of Stack-ResNet18, we select Stack-ResNet18 and Stack-ResNet34 as backbones for fair comparison between MobRecon and M3DHMR. Our ResNet34-based M3DHMR achieves the best performance among real-time methods on camera-space mesh recovery. Specifically, M3DHMR reaches lowest 6.5mm PA-MPJPE, lowest 6.6mm PA-MPVPE and highest F@5 of 0.739. Additionally, its F@15 of 0.980 also outperforms most compared approaches, only slightly lower than CLIP-Hand3D and FastViT. Furthermore, a qualitative comparison of our M3DHMR with two other state-of-the-art real-time methods is presented in Fig. \ref{fig5}. It can be observed that our method demonstrates superior performance in terms of detail reconstruction. More results are shown in Fig. S2 in the Supplemental Material.
2025Ours (Foundation-to-Diffusion; single-hand comparison) proposedPA-MPJPE5.3 mmSingle-hand comparison; omits relative-translation estimation and two-hand diffusion de…Aligning Foundation Model Priors and Diffusion-Based Hand Interactions for Occlusion-Resistant Two-Hand Reconstruction
Source quote
L163: Ours │ 5.3 │ 5.4
2024A Simple Baseline for Efficient Hand Mesh Reconstruction (proposed method) proposedPA-MPJPE5.8mmDataset-level score as reported; the cited text does not specify a split or backbone.A Simple Baseline for Efficient Hand Mesh Reconstruction
Source quote
L6: Hand mesh reconstruction has attracted considerable attention in recent years, with various approaches and techniques being proposed. Some of these methods incorporate complex components and designs, which, while effective, may complicate the model and hinder efficiency. In this paper, we decompose the mesh decoder into token generator and mesh regressor. Through extensive ablation experiments, we found that the token generator should select discriminating and representative points, while the mesh regressor needs to upsample sparse keypoints into dense meshes in multiple stages. Given these functionalities, we can achieve high performance with minimal computational resources. Based on this observation, we propose a simple yet effective baseline that outperforms state-of-the-art methods by a large margin, while maintaining real-time efficiency. Our method outperforms existing solutions, achieving state-of-the-art (SOTA) results across multiple datasets. On the FreiHAND dataset, our approach produced a PA-MPJPE of 5.8mm and a PA-MPVPE of 6.1mm. Similarly, on the DexYCB dataset, we observed a PA-MPJPE of 5.5mm and a PA-MPVPE of 5.5mm. As for performance speed, our method reached up to 33 frames per second (fps) when using HRNet and up to 70 fps when employing FastViT-MA36. Code will be made available.
2024HandOS proposedPA-MPJPE5.0 mmProcrustes-aligned error; split and training conditions are not specified in the cited …HandOS: 3D Hand Reconstruction in One Stage
Source quote
L14: Existing approaches of hand reconstruction predominantly adhere to a multi-stage framework, encompassing detection, left-right classification, and pose estimation. This paradigm induces redundant computation and cumulative errors. In this work, we propose HandOS, an end-to-end framework for 3D hand reconstruction. Our central motivation lies in leveraging a frozen detector as the foundation while incorporating auxiliary modules for 2D and 3D keypoint estimation. In this manner, we integrate the pose estimation capacity into the detection framework, while at the same time obviating the necessity of using the left-right category as a prerequisite. Specifically, we propose an interactive 2D-3D decoder, where 2D joint semantics is derived from detection cues while 3D representation is lifted from those of 2D joints. Furthermore, hierarchical attention is designed to enable the concurrent modeling of 2D joints, 3D vertices, and camera translation. Consequently, we achieve an end-to-end integration of hand detection, 2D pose estimation, and 3D mesh reconstruction within a one-stage framework, so that the above multi-stage drawbacks are overcome. Meanwhile, the HandOS reaches state-of-the-art performances on public benchmarks, e.g., 5.0 PA-MPJPE on FreiHand and 64.6% [email protected] on HInt-Ego4D.
2023Lite I2L Mesh Net (Frei+MR+AR) proposedPA-MPJPE7.0 mmsplit: test · training-data=FreiHand+ManoRender+AngRenderLightweight Estimation of Hand Mesh and Biomechanically Feasible Kinematic Parameters
Source quote
L229: Lite I2L Mesh Net │ Frei+MR+AR │ 7.0 │ 7.1 │ 0.700 │ 0.979 │ 3.75
2023Lite I2L Mesh Net + Our IK + Post Opt. proposed non-standard slicePA-MPJPE6.9 mmsplit: test · method=biomechanically-feasible-IK · shape-parameters=10 · post-optimization=20-iterationsLightweight Estimation of Hand Mesh and Biomechanically Feasible Kinematic Parameters
Source quote
L247: Our IK + Post Opt. │ 23+10 │ \ding{55} │ 6.9 │ 7.0 │ 0.706 │ 0.980
2023Lite I2L Mesh Net + Our IK + Post Opt. (known shape) proposedPA-MPJPE3.7 mmsplit: val · shape=known · method=biomechanically-feasible-IK · validation-split=train-derived-9:1Lightweight Estimation of Hand Mesh and Biomechanically Feasible Kinematic Parameters
Source quote
L249: Our IK + Post Opt.^\dagger │ 23 │ \ding{51} │ 3.7 │ 3.8 │ 0.919 │ 0.999
2023ACR (HRNet-32W) proposedPA-MPJPE6.9 mmsplit: test · fine-tuned · setting=single-hand · backbone=HRNet-32WACR: Attention Collaboration-based Regressor for Arbitrary Two-Hand Reconstruction
Source quote
L215: ours │ 6.9 │ 7.0
2022NIMBLE proposed non-standard slicePA MPJPE9.4 mmsplit: test · input=RGB · joint-mapping=21-keypoint evaluation from 25 anatomical jointsNIMBLE: a non-rigid hand model with bones and muscles
Source quote
L588: NIMBLE │ 9.4 │ 0.547 │ 0.955
2022MPT proposedPA-MPJPE5.6pretraining-data=ComplementMPT: Mesh Pre-Training with Transformers for Human Pose and Mesh Reconstruction
Source quote
L312: MPT (Ours) │ 5.4 │ 5.6 │ 0.789 │ 0.988
2022Mask2Hand (Ours, 45 pose PCs) proposedPA-MPJPE0.68 cmsplit: test · input=binary-mask · subset=authors' random 3,280-image split · alignment=Procrustes-alignedMask2Hand: Learning to Predict the 3D Hand Pose and Shape from Shadow
Source quote
L264: Ours (45 pose PCs) │ 0.68 │ 0.86 │ 0.69 │ 0.86
2022Ours with GCN proposedPA-MPJPE5.9 mmsplit: test · backbone=GCN · feature-extractor=CMRPixel-Aligned Non-parametric Hand Mesh Reconstruction
Source quote
L194: Ours with GCN │ 5.9 │ 6.0 │ 0.766 │ 0.985
2022Ours with METRO proposedPA-MPJPE6.1 mmsplit: test · mapping=pixel-aligned · backbone=METRO · skip-connection=usedPixel-Aligned Non-parametric Hand Mesh Reconstruction
Source quote
L193: Ours with METRO │ 6.1 │ 6.2 │ 0.757 │ 0.984
2021HandTailor proposedPA-MPJPE8.2FreiHAND benchmark; score from the HandTailor row in the comparison table.HandTailor: Towards High-Precision Monocular 3D Hand Recovery
Source quote
L230: HandTailor │ 8.2 │ 8.7
2021ResNet50-based CMR-PG proposedPA-MPJPE6.9mmsplit: test · backbone=ResNet50 · evaluation=official-serverCamera-Space Hand Mesh Recovery via Semantic Aggregation and Adaptive 2D-1D Registration
Source quote
L499: Specifically, ResNet50-based CMRPG achieves the best performance on root-relative mesh recovery, i.e., 7.0mm PA-MPVPE and 6.9mm PA-MPJPE.
2021MobRecon (ours†), ResNet50* stacked structure proposedPA-MPJPE5.7 mmfine-tuned · backbone=ResNet50 · resolution=224×224MobRecon: Mobile-Friendly Hand Mesh Reconstruction from Monocular Image
Source quote
L689: 5.7