FMD

17 papers · 37 extracted observations · image denoising · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching regime=0-shot.

33.735.938.040.2202220242025INR (proposed method; SIREN with 6 hidden layers): 39.76 (2022)FM2S (full configuration; “Full Conduction” row): 34.15 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 3 of 3 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024FM2S (full configuration; “Full Conduction” row) proposedPSNR34.150-shotFM2S: Towards Spatially-Correlated Noise Modeling in Zero-Shot Fluorescence Microscopy Image Denoising
Source quote
L285: (e) w/ Stage 2 Only │ 34.08 │ 0.884 │ 28.82 │ 0.916 (f) Full Conduction │ 34.15 │ 0.886 │ 28.93 │ 0.919
2022INR (proposed method; SIREN with 6 hidden layers) proposedmean PSNR39.760-shot · backbone=SIREN · hidden-layers=6 · input-samples=4 high-noise samplesZero-shot Blind Image Denoising via Implicit Neural Representations
Source quote
L149: INR │ 34.01 / 0.809 │ 36.83 / 0.863 │ 39.76 / 0.903 │ 40.01 / 0.968 │ 41.56 / 0.977
2022S2S (Self2Self) baselinemean PSNR26.690-shot · method=Self2Self · input-samples=4 high-noise samplesZero-shot Blind Image Denoising via Implicit Neural Representations
Source quote
L148: S2S │ 30.71 / 0.595 │ 30.31 / 0.802 │ 26.69 / 0.470 │ 39.21 / 0.715 │ 36.00 / 0.550