# ETIS (`etis`)

- **Canonical ID**: `bmk_ec87dc6a5075557c`
- **Task**: polyp-segmentation · **Modality**: vision
- **Coverage**: 23 papers · 38 observations
- **Tasks Evaluated**: Polyp Segmentation (`?task=polyp-segmentation`, 18 papers), Image Segmentation (`?task=image-segmentation`, 3 papers), Medical Image Segmentation (`?task=medical-image-segmentation`, 1 papers), Video Polyp Segmentation (`?task=video-polyp-segmentation`, 1 papers)

## Comparable Cohort Leaderboards

### Image Segmentation · DSC ↑ (2 papers)

| # | Method | Score | Year | Settings | Paper |
| ---: | --- | ---: | --- | --- | --- |
| 1 | MCTrans | 83.69 | 2021-06-01 | - | [Multi-compound Transformer for Accurate Biomedical Image Segmentation](/work/multi-compound-transformer-for-accurate-biomedical-image) |
| 2 | U-Net v2 | 79 | 2023-11-01 | - | [U-Net V2: Rethinking the Skip Connections of U-Net for Medical Image Segmentation](/work/u-net-v2-rethinking-the-skip-connections) |

## Recent Extracted Observations

| Year | Method | Role | Metric | Score | Split | Regime | Paper | Verbatim Quote |
| --- | --- | --- | --- | ---: | --- | --- | --- | --- |
| 2023 | U-Net v2 | proposed | DSC | 79.0 | - | - | [U-Net V2: Rethinking the Skip Connections of U-Net for Medical Image Segmentation](/work/u-net-v2-rethinking-the-skip-connections) | & U-Net v2 (ours)&79.0 & {70.5} & 0.013 |
| 2023 | Polyp-PVT | baseline | DSC | 78.7 | - | - | [U-Net V2: Rethinking the Skip Connections of U-Net for Medical Image Segmentation](/work/u-net-v2-rethinking-the-skip-connections) | & Polyp-PVT~\cite{dong2021polyp}& 78.7 & 70.6 & 0.013 |
| 2022 | SSFormer-L | proposed | mDic | 0.796 | test | - | [Stepwise Feature Fusion: Local Guides Global](/work/stepwise-feature-fusion-local-guides-global) | SSformer-L & \multicolumn{1}{c\|}{0.802} & 0.721 & \multicolumn{1}{c\|}{0.796} & 0.720 |
| 2022 | UACANet-L | baseline | mDic | 0.766 | test | - | [Stepwise Feature Fusion: Local Guides Global](/work/stepwise-feature-fusion-local-guides-global) | UACANet-L & \multicolumn{1}{c\|}{0.751} & 0.678 & \multicolumn{1}{c\|}{0.766} & 0.689 |
| 2021 | MCTrans | proposed | DSC | 83.69 | - | - | [Multi-compound Transformer for Accurate Biomedical Image Segmentation](/work/multi-compound-transformer-for-accurate-biomedical-image) | MCTrans&92.30&86.58&83.69&86.20&90.35 |