Esophageal Cancer Dataset
3 papers · 11 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Also indexed as: esophageal-cancer-dataset
Showing 11 of 11 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2023 | Implicit station stratification method proposed non-standard slice | Detection sensitivity | 85.5% | false_positives_per_patient=2 | Anatomy-Aware Lymph Node Detection in Chest CT using Implicit Station StratificationSource quoteL4: Finding abnormal lymph nodes in radiological images is highly important for various medical tasks such as cancer metastasis staging and radiotherapy planning. Lymph nodes (LNs) are small glands scattered throughout the body. They are grouped or defined to various LN stations according to their anatomical locations. The CT imaging appearance and context of LNs in different stations vary significantly, posing challenges for automated detection, especially for pathological LNs. Motivated by this observation, we propose a novel end-to-end framework to improve LN detection performance by leveraging their station information. We design a multi-head detector and make each head focus on differentiating the LN and non-LN structures of certain stations. Pseudo station labels are generated by an LN station classifier as a form of multi-task learning during training, so we do not need another explicit LN station prediction model during inference. Our algorithm is evaluated on 82 patients with lung cancer and 91 patients with esophageal cancer. The proposed implicit station stratification method improves the detection sensitivity of thoracic lymph nodes from 65.1% to 71.4% and from 80.3% to 85.5% at 2 false positives per patient on the two datasets, respectively, which significantly outperforms various existing state-of-the-art baseline techniques such as nnUNet, nnDetection and LENS. |
| 2020 | Proposed OSLN detection system proposed non-standard slice | Detection recall | 67% | operating-point=3 FPs per patient or scan | Detecting Scatteredly-Distributed, Small, andCritically Important Objects in 3D OncologyImaging via Decision StratificationSource quoteL40: \item We collect and evaluate on the largest dataset to date on chest and abdominal radiotherapy. Our dataset comprises of 651 voxelwise-labeled OSLNs (by board-certified radiation oncologists) of 141 esophageal cancer patients. Our system significantly improves the detection recall from 45% to 67% at 3 FPs per scan, compared against the previous state-of-the-art CT-based detection method \cite{yan2019mulan}. The highest achieved recall of 0.828 for OSLNs detection is also clinically relevant and valuable. |
| 2020 | LF (GLNet) ablation | mFROC | 0.645 | split: test · first-stage=LF · second-stage=GLNet | Detecting Scatteredly-Distributed, Small, andCritically Important Objects in 3D OncologyImaging via Decision StratificationSource quoteL216: Table.~\ref{Tab:FullResults} also compares the proposed two-stage OSLN detection method with 2 state-of-the-art methods, {\it{i.e.}}, the multi-task universal lesion analysis network (MULAN)~\cite{yan2019mulan} (achieves the best general lesion detection results in the DeepLesion dataset) and a 2.5D CNN method for classifying enlarged LNs~\cite{roth2015improving} (achieves the best 2nd-stage LN classification results in the enlarged LN dataset). We retrain the MULAN using both CT and CT+PET as inputs on our radiotherapy dataset. The tagging information is naturally incorporated in MULAN regardless of input channels. Several conclusions can be drawn. First, MULAN's results, based on the CT+PET input (0.475 mFROC), are better than those based on the CT alone (0.348 mFROC), which again demonstrates the importance of PET imaging in the OSLN detecting task, even when using a single end-to-end trained model. Second, MULAN's best performance is just comparable with our best 1st-stage-only results, {\it{i.e.}}, (LF\#). This demonstrates the effectiveness of our 1st-stage with distance stratification and the two-stream network fusion. Third, our complete pipeline, regardless of the 1st-stage settings, significantly outperforms the best MULAN results, {\it{e.g.}}, CT (GLNet) achieves an mFROC score of 0.563 as compared to 0.475 from MULAN, whereas LF (GLNet) further boosts the mFROC to 0.645. This is a 22% improvement and highlights the advantages of our two-stage method, which is tailored to achieve maximum performance gain on the challenging and unique OSLN problem. |
| 2020 | CT (GLNet) ablation | mFROC | 0.563 | split: test · first-stage=CT · second-stage=GLNet | Detecting Scatteredly-Distributed, Small, andCritically Important Objects in 3D OncologyImaging via Decision StratificationSource quoteL216: Table.~\ref{Tab:FullResults} also compares the proposed two-stage OSLN detection method with 2 state-of-the-art methods, {\it{i.e.}}, the multi-task universal lesion analysis network (MULAN)~\cite{yan2019mulan} (achieves the best general lesion detection results in the DeepLesion dataset) and a 2.5D CNN method for classifying enlarged LNs~\cite{roth2015improving} (achieves the best 2nd-stage LN classification results in the enlarged LN dataset). We retrain the MULAN using both CT and CT+PET as inputs on our radiotherapy dataset. The tagging information is naturally incorporated in MULAN regardless of input channels. Several conclusions can be drawn. First, MULAN's results, based on the CT+PET input (0.475 mFROC), are better than those based on the CT alone (0.348 mFROC), which again demonstrates the importance of PET imaging in the OSLN detecting task, even when using a single end-to-end trained model. Second, MULAN's best performance is just comparable with our best 1st-stage-only results, {\it{i.e.}}, (LF\#). This demonstrates the effectiveness of our 1st-stage with distance stratification and the two-stream network fusion. Third, our complete pipeline, regardless of the 1st-stage settings, significantly outperforms the best MULAN results, {\it{e.g.}}, CT (GLNet) achieves an mFROC score of 0.563 as compared to 0.475 from MULAN, whereas LF (GLNet) further boosts the mFROC to 0.645. This is a 22% improvement and highlights the advantages of our two-stage method, which is tailored to achieve maximum performance gain on the challenging and unique OSLN problem. |
| 2020 | Previous state-of-the-art CT-based detection method (MULAN) baseline non-standard slice | Detection recall | 45% | operating-point=3 FPs per patient or scan | Detecting Scatteredly-Distributed, Small, andCritically Important Objects in 3D OncologyImaging via Decision StratificationSource quoteL40: \item We collect and evaluate on the largest dataset to date on chest and abdominal radiotherapy. Our dataset comprises of 651 voxelwise-labeled OSLNs (by board-certified radiation oncologists) of 141 esophageal cancer patients. Our system significantly improves the detection recall from 45% to 67% at 3 FPs per scan, compared against the previous state-of-the-art CT-based detection method \cite{yan2019mulan}. The highest achieved recall of 0.828 for OSLNs detection is also clinically relevant and valuable. |
| 2019 | CGGNN proposed | DSC — GTV | 82.69% | split: val · 5-fold-cross-validation | Radiotherapy Target Contouring with Convolutional Gated Graph Neural NetworkSource quoteL157: Ours │ 82.69% │ 86.00% │ 90.27% │ 80.49% │ 85.67% │ 92.17% │ 99.83% │ 99.33% │ 98.94% |
| 2019 | CGGNN proposed | DSC — CTV | 86.00% | split: val · 5-fold-cross-validation | Radiotherapy Target Contouring with Convolutional Gated Graph Neural NetworkSource quoteL157: Ours │ 82.69% │ 86.00% │ 90.27% │ 80.49% │ 85.67% │ 92.17% │ 99.83% │ 99.33% │ 98.94% |
| 2019 | CGGNN proposed | DSC — PTV | 90.27% | split: val · 5-fold-cross-validation | Radiotherapy Target Contouring with Convolutional Gated Graph Neural NetworkSource quoteL157: Ours │ 82.69% │ 86.00% │ 90.27% │ 80.49% │ 85.67% │ 92.17% │ 99.83% │ 99.33% │ 98.94% |
| 2019 | 3D U-Net baseline | DSC — GTV | 79.20% | split: val · 5-fold-cross-validation | Radiotherapy Target Contouring with Convolutional Gated Graph Neural NetworkSource quoteL156: 3D U-Net │ 79.20% │ 85.73% │ 89.29% │ 78.03% │ 84.39% │ 86.93% │ 99.80% │ 99.40% │ 99.37% |
| 2019 | 3D U-Net baseline | DSC — CTV | 85.73% | split: val · 5-fold-cross-validation | Radiotherapy Target Contouring with Convolutional Gated Graph Neural NetworkSource quoteL156: 3D U-Net │ 79.20% │ 85.73% │ 89.29% │ 78.03% │ 84.39% │ 86.93% │ 99.80% │ 99.40% │ 99.37% |
| 2019 | 3D U-Net baseline | DSC — PTV | 89.29% | split: val · 5-fold-cross-validation | Radiotherapy Target Contouring with Convolutional Gated Graph Neural NetworkSource quoteL156: 3D U-Net │ 79.20% │ 85.73% │ 89.29% │ 78.03% │ 84.39% │ 86.93% │ 99.80% │ 99.40% │ 99.37% |