eICU

45 papers · 115 extracted observations · mortality prediction · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Mortality Prediction.

0.10.40.71.0202220242025GCT, Original Loss function: 0.145 (2022)GCT, Original Loss function: 0.548 (2022)MUSE: 0.9017 (2024)MUSE+: 0.9332 (2024)MEDS-Tab (XGBoost): 0.855 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 37 of 37 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025KnowRare proposedAUPRC0.709Mortality Prediction · split: test · input-window=first 24 hours of ICU admission · adaptation-subset=10% of conditionsBridging data gaps of rare conditions in ICU: a multi-disease adaptation approach for clinical prediction
Source quote
L77: KnowRare (Ours) │ 0.744 (0.051) │ 0.797 (0.032) │ 0.716(0.031) │ 0.749 (0.034) │ 0.709(0.022) │ 0.757 (0.012) │ 0.206 (0.024) │ 0.509 (0.030) │ 0.244 (0.039) │ 0.609 (0.044)
2025KnowRare proposedAUPRC0.206Length of Stay Prediction · split: test · target=remaining ICU stay, 10 intervals · input-window=first 24 hours of ICU admission · adaptation-subset=10% of conditionsBridging data gaps of rare conditions in ICU: a multi-disease adaptation approach for clinical prediction
Source quote
L77: KnowRare (Ours) │ 0.744 (0.051) │ 0.797 (0.032) │ 0.716(0.031) │ 0.749 (0.034) │ 0.709(0.022) │ 0.757 (0.012) │ 0.206 (0.024) │ 0.509 (0.030) │ 0.244 (0.039) │ 0.609 (0.044)
2025KnowRare proposedAUPRC0.244Phenotyping · split: test · target=25 acute-care phenotypes · input-window=first 24 hours of ICU admission · adaptation-subset=10% of conditionsBridging data gaps of rare conditions in ICU: a multi-disease adaptation approach for clinical prediction
Source quote
L77: KnowRare (Ours) │ 0.744 (0.051) │ 0.797 (0.032) │ 0.716(0.031) │ 0.749 (0.034) │ 0.709(0.022) │ 0.757 (0.012) │ 0.206 (0.024) │ 0.509 (0.030) │ 0.244 (0.039) │ 0.609 (0.044)
2025TrajSurv proposed non-standard sliceC-index0.760Survival Prediction · split: test · subset=random sample of 4,000 patients · evaluation=cross-cohort · training-cohort=MIMIC-IIITrajSurv: Learning Continuous Latent Trajectories from Electronic Health Records for Trustworthy Survival Prediction
Source quote
L210: \paragraph{Cross-Cohort Generalization} To assess out-of-distribution generalization, we performed a cross-cohort evaluation by training TrajSurv on the full MIMIC-III training set and testing it on a random sample of 4,000 patients from the eICU dataset. The model achieved a C-index of 0.760 and a Brier score of 0.038, demonstrating robust performance on unseen data from different hospital systems.
2025TrajSurv proposed non-standard sliceBrier score0.038Survival Prediction · split: test · subset=random sample of 4,000 patients · evaluation=cross-cohort · training-cohort=MIMIC-IIITrajSurv: Learning Continuous Latent Trajectories from Electronic Health Records for Trustworthy Survival Prediction
Source quote
L210: \paragraph{Cross-Cohort Generalization} To assess out-of-distribution generalization, we performed a cross-cohort evaluation by training TrajSurv on the full MIMIC-III training set and testing it on a random sample of 4,000 patients from the eICU dataset. The model achieved a C-index of 0.760 and a Brier score of 0.038, demonstrating robust performance on unseen data from different hospital systems.
2025Enhanced TimeAutoDiff proposed non-standard sliceMean subgroup AUROC estimation error0.028Binary Classification · split: test · cohort=large conditionally generated synthetic cohort · method=Enhanced TimeAutoDiff · outcome=LOS₍₂₄₎Enabling Granular Subgroup Level Model Evaluations by Generating Synthetic Medical Time Series
Source quote
L221: Fig.\@ \ref{fig4} shows that, in every case, the synthetic cohorts cut the error roughly in half compared to the small real‐test subsets (red bar), and our enhanced generator (Enhanced TimeAutoDiff) yields the lowest errors of all. For example, on eICU LOS-24 the mean error drops from 0.044 (Test) to 0.039 (TimeAutoDiff), 0.033 (TimeDiff), and 0.028 (Enhanced TimeAutoDiff); on MIMIC Mortality-24 it falls from 0.142 to 0.081, 0.088, and 0.081 respectively; On eICU Mortality-24: 0.075 → 0.061 → 0.056 → 0.050, and on MIMIC LOS-24: 0.067 → 0.043 → 0.049 → 0.042.
2025Stable-CRP baselineAUPRC0.631Mortality Prediction · split: test · input-window=first 24 hours of ICU admissionBridging data gaps of rare conditions in ICU: a multi-disease adaptation approach for clinical prediction
Source quote
L72: Stable-CRP \cite{lee2023stable} │ 0.726 (0.041) │ 0.819 (0.027) │ 0.646 (0.069) │ 0.686 (0.062) │ 0.631 (0.053) │ 0.691 (0.027) │ 0.077(0.027) │ 0.501 (0.026) │ 0.158 (0.034) │ 0.546 (0.029)
2025Small real test subset (Test) baseline non-standard sliceMean subgroup AUROC estimation error0.044Binary Classification · split: test · subset=small real test subset · outcome=LOS₍₂₄₎Enabling Granular Subgroup Level Model Evaluations by Generating Synthetic Medical Time Series
Source quote
L221: Fig.\@ \ref{fig4} shows that, in every case, the synthetic cohorts cut the error roughly in half compared to the small real‐test subsets (red bar), and our enhanced generator (Enhanced TimeAutoDiff) yields the lowest errors of all. For example, on eICU LOS-24 the mean error drops from 0.044 (Test) to 0.039 (TimeAutoDiff), 0.033 (TimeDiff), and 0.028 (Enhanced TimeAutoDiff); on MIMIC Mortality-24 it falls from 0.142 to 0.081, 0.088, and 0.081 respectively; On eICU Mortality-24: 0.075 → 0.061 → 0.056 → 0.050, and on MIMIC LOS-24: 0.067 → 0.043 → 0.049 → 0.042.
2024FlexTSF proposedMSE0.593Time Series Forecasting · split: test · 0-shotFlexTSF: A Universal Forecasting Model for Time Series with Variable Regularities
Source quote
L323: eICU │ 0.710 │ 0.915 │ 0.878 │ 0.604 │ 0.944 │ 0.593
2024CDM proposed non-standard sliceEmpirical coverage probability of the 95% interval estimate for ITE (mean)0.948Treatment Effect Estimation · split: test · subset=age < 62 · treatment=norepinephrine · distribution=shifted from calibration dataConformal Diffusion Models for Individual Treatment Effect Estimation and Inference
Source quote
L295: CDM │ 0.948 │ [0.938, 0.957] │ 5.066 │ [4.790, 5.341]
2024UniHPFcl proposedMacro F10.6937Mortality Prediction · split: test · loss=hybridKnowledge-aware Attention Network for Medication Effectiveness Prediction
Source quote
L248: 0.6937
2024UniHPFcl proposedMacro F10.6681Length of Stay Prediction · split: test · loss=hybrid · threshold=7 daysKnowledge-aware Attention Network for Medication Effectiveness Prediction
Source quote
L250: 0.6681
2024UniHPFcl proposedMacro F10.7241Apache Score Prediction · split: test · loss=hybrid · threshold=>50Knowledge-aware Attention Network for Medication Effectiveness Prediction
Source quote
L252: 0.7241 ours
2024FedMAP proposedAUROC0.808Mortality Prediction · split: test · tier=1 · sites=51FedMAP: Personalised Federated Learning for Real Large-Scale Healthcare Systems
Source quote
L42: On the INTERVAL dataset (3 T1 sites), FedAvg achieved a median balanced accuracy of 0.760 (IQR: 0.013), with PFL methods showing mixed performance: pFedBayes reached 0.773 (IQR: 0.017), pFedGP 0.771 (IQR: 0.015), pFedFDA 0.768 (IQR: 0.010), and pFedME 0.737 (IQR: 0.025). Individual training achieved 0.779 (IQR: 0.025). FedMAP achieved the highest median balanced accuracy of 0.786 (IQR: 0.013). The eICU dataset (51 sites) showed similar patterns, with FedAvg achieving a median AUROC of 0.787 (IQR: 0.124), PFL methods ranging from pFedME's 0.772 (IQR: 0.107) to pFedGP's 0.732 (IQR: 0.173), and individual training at 0.701 (IQR: 0.139). FedMAP achieved a median AUROC of 0.808 (IQR: 0.116), significantly outperforming individual training (p<0.001, MD =0.098) and demonstrating improvement over FedAvg (p=0.057, MD =0.019).
2024CDM-nolocal ablation non-standard sliceEmpirical coverage probability of the 95% interval estimate for ITE (mean)0.858Treatment Effect Estimation · split: test · subset=age < 62 · treatment=norepinephrine · distribution=shifted from calibration dataConformal Diffusion Models for Individual Treatment Effect Estimation and Inference
Source quote
L297: CDM-nolocal │ 0.858 │ [0.847, 0.869] │ 3.092 │ [3.044, 3.140]
2024CQR baseline non-standard sliceEmpirical coverage probability of the 95% interval estimate for ITE (mean)0.927Treatment Effect Estimation · split: test · subset=age < 62 · treatment=norepinephrine · distribution=shifted from calibration dataConformal Diffusion Models for Individual Treatment Effect Estimation and Inference
Source quote
L296: CQR │ 0.927 │ [0.920, 0.935] │ 3.191 │ [3.162, 3.220]
2024FedAvg baselineAUROC0.787Mortality Prediction · split: test · tier=1 · sites=51FedMAP: Personalised Federated Learning for Real Large-Scale Healthcare Systems
Source quote
L42: On the INTERVAL dataset (3 T1 sites), FedAvg achieved a median balanced accuracy of 0.760 (IQR: 0.013), with PFL methods showing mixed performance: pFedBayes reached 0.773 (IQR: 0.017), pFedGP 0.771 (IQR: 0.015), pFedFDA 0.768 (IQR: 0.010), and pFedME 0.737 (IQR: 0.025). Individual training achieved 0.779 (IQR: 0.025). FedMAP achieved the highest median balanced accuracy of 0.786 (IQR: 0.013). The eICU dataset (51 sites) showed similar patterns, with FedAvg achieving a median AUROC of 0.787 (IQR: 0.124), PFL methods ranging from pFedME's 0.772 (IQR: 0.107) to pFedGP's 0.732 (IQR: 0.173), and individual training at 0.701 (IQR: 0.139). FedMAP achieved a median AUROC of 0.808 (IQR: 0.116), significantly outperforming individual training (p<0.001, MD =0.098) and demonstrating improvement over FedAvg (p=0.057, MD =0.019).
2023DySurv (+ time-series) proposedtime-dependent concordance (C_ind^td)60.3Survival Analysis · split: test · features=time-seriesDySurv: dynamic deep learning model for survival analysis with conditional variational inference
Source quote
L279: DySurv (+ time-series) │ 60.3 │ 0.102 │ 0.319
2023Dynamic-DeepHit baselinetime-dependent concordance (C_ind^td)58.8Survival Analysis · split: testDySurv: dynamic deep learning model for survival analysis with conditional variational inference
Source quote
L278: Dynamic-DeepHit │ 58.8 │ 0.131 │ 0.352
2022UniHPF (hi) proposedAUPRC0.169Mortality Prediction · split: test · fine-tuned · time-gap=12-hour · input-duration=12-hour · prediction-window=48-hourUniHPF : Universal Healthcare Predictive Framework with Zero Domain Knowledge
Source quote
L523: \multirow{7}{*}{eICU} │ Mort │ \multicolumn{1}{c|}{0.169} │ \multicolumn{1}{c|}{0.167} │ \multicolumn{1}{c|}{0.148} │ \multicolumn{1}{c|}{0.150} │ 0.151
2022Wav2Vec (hierarchical) baselineAUPRC0.167Mortality Prediction · split: test · fine-tuned · time-gap=12-hour · input-duration=12-hour · prediction-window=48-hourUniHPF : Universal Healthcare Predictive Framework with Zero Domain Knowledge
Source quote
L523: \multirow{7}{*}{eICU} │ Mort │ \multicolumn{1}{c|}{0.169} │ \multicolumn{1}{c|}{0.167} │ \multicolumn{1}{c|}{0.148} │ \multicolumn{1}{c|}{0.150} │ 0.151
2019PSV (Code+Signal) proposedPR-AUC62.46Mortality Prediction · split: test · cohort=1h-24h · test-subset=random 15%Unsupervised Representation for EHR Signals and Codes as Patient Status Vector
Source quote
L168: {PSV} {\texttt{(Code+Signal)}} │ 62.46 {(± 0.20)} │ \bf 90.06 {(± 0.12)} │ 48.88 {(± 0.13)} │ \bf 85.90 {(± 0.09)}
2019PSV (Code+Signal) proposedROC90.06Mortality Prediction · split: test · cohort=1h-24h · test-subset=random 15%Unsupervised Representation for EHR Signals and Codes as Patient Status Vector
Source quote
L168: {PSV} {\texttt{(Code+Signal)}} │ 62.46 {(± 0.20)} │ \bf 90.06 {(± 0.12)} │ 48.88 {(± 0.13)} │ \bf 85.90 {(± 0.09)}
2019PSV (Code+Signal) proposedPR-AUC48.88Mortality Prediction · split: test · cohort=24h-720h · test-subset=random 15%Unsupervised Representation for EHR Signals and Codes as Patient Status Vector
Source quote
L168: {PSV} {\texttt{(Code+Signal)}} │ 62.46 {(± 0.20)} │ \bf 90.06 {(± 0.12)} │ 48.88 {(± 0.13)} │ \bf 85.90 {(± 0.09)}
2019PSV (Code+Signal) proposedROC85.90Mortality Prediction · split: test · cohort=24h-720h · test-subset=random 15%Unsupervised Representation for EHR Signals and Codes as Patient Status Vector
Source quote
L168: {PSV} {\texttt{(Code+Signal)}} │ 62.46 {(± 0.20)} │ \bf 90.06 {(± 0.12)} │ 48.88 {(± 0.13)} │ \bf 85.90 {(± 0.09)}
2019Graph Convolutional Transformer (GCT) proposedAUROC0.7502Readmission Prediction · split: testLearning the Graphical Structure of Electronic Health Records with Graph Convolutional Transformer
Source quote
L685: GCT\xspace │ 0.7525 (0.0128) │ 0.7502 (0.0114) │ 0.9089 (0.0052) │ 0.9120 (0.0048)
2019Deep baselineAUROC0.7412Readmission Prediction · split: testLearning the Graphical Structure of Electronic Health Records with Graph Convolutional Transformer
Source quote
L683: Deep │ 0.7478 (0.0124) │ 0.7412 (0.0074) │ 0.9101 (0.0057) │ 0.9092 (0.0060)
2018Distributed Private proposedAUROC0.662Mortality Prediction · split: test · institutions=1Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L84: 1 │ 0.743 │ 0.683 │ 0.738 │ 0.662
2018Distributed Private proposedAUROC0.706Mortality Prediction · split: test · institutions=2Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L85: 2 │ 0.760 │ 0.720 │ 0.762 │ 0.706
2018Distributed Private proposedAUROC0.753Mortality Prediction · split: test · institutions=3Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L86: 3 │ 0.794 │ 0.780 │ 0.789 │ 0.753
2018Federated autonomous deep learning (FADL) proposedAUCROC0.79Mortality Prediction · split: test · input=medications from first 24 hours · hospitals=58 · federated-setting=first half trained globally, second half locallyFADL: Federated-Autonomous Deep Learning for Distributed Electronic Health Record
Source quote
L78: Federated autonomous deep learning (FADL) │ 0.79 │ 0.23
2018Federated autonomous deep learning (FADL) proposedAUCPR0.23Mortality Prediction · split: test · input=medications from first 24 hours · hospitals=58 · federated-setting=first half trained globally, second half locallyFADL: Federated-Autonomous Deep Learning for Distributed Electronic Health Record
Source quote
L78: Federated autonomous deep learning (FADL) │ 0.79 │ 0.23
2018Central Private baselineAUROC0.683Mortality Prediction · split: test · institutions=1Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L84: 1 │ 0.743 │ 0.683 │ 0.738 │ 0.662
2018Central Private baselineAUROC0.720Mortality Prediction · split: test · institutions=2Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L85: 2 │ 0.760 │ 0.720 │ 0.762 │ 0.706
2018Central Private baselineAUROC0.780Mortality Prediction · split: test · institutions=3Privacy-Preserving Distributed Deep Learning for Clinical Data
Source quote
L86: 3 │ 0.794 │ 0.780 │ 0.789 │ 0.753
2018Original federated learning baselineAUCROC0.75Mortality Prediction · split: test · input=medications from first 24 hours · hospitals=58 · federated-setting=original federated learningFADL: Federated-Autonomous Deep Learning for Distributed Electronic Health Record
Source quote
L77: Original federated learning │ 0.75 │ 0.16
2018Original federated learning baselineAUCPR0.16Mortality Prediction · split: test · input=medications from first 24 hours · hospitals=58 · federated-setting=original federated learningFADL: Federated-Autonomous Deep Learning for Distributed Electronic Health Record
Source quote
L77: Original federated learning │ 0.75 │ 0.16