eICU

45 papers · 115 extracted observations · mortality prediction · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Proposed/measured results matching task=Mortality Prediction.

0.10.40.71.0202220242025GCT, Original Loss function: 0.145 (2022)GCT, Original Loss function: 0.548 (2022)MUSE: 0.9017 (2024)MUSE+: 0.9332 (2024)MEDS-Tab (XGBoost): 0.855 (2024)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024Mixed model (LSTM trained with a combination of all three utility measures) proposedRMSE1.167Heart Rate PredictionAiming for Relevance
Source quote
L156: 94 events over 45 patients with average length of 15 steps. The held-out RMSE over the entire signal for the baseline model is 1.205 while the corresponding RMSE of the Mixed model is only slight better at 1.167. However, the Mixed model had a greater advantage in RMSE taken only over the annotated events 1.276 compared to 1.485 for the baseline.
2024Mixed model (LSTM trained with a combination of all three utility measures) proposed non-standard sliceRMSE1.276Heart Rate Prediction · subset=clinician-annotated eventsAiming for Relevance
Source quote
L156: 94 events over 45 patients with average length of 15 steps. The held-out RMSE over the entire signal for the baseline model is 1.205 while the corresponding RMSE of the Mixed model is only slight better at 1.167. However, the Mixed model had a greater advantage in RMSE taken only over the annotated events 1.276 compared to 1.485 for the baseline.
2024Baseline LSTM trained with square loss baselineRMSE1.205Heart Rate PredictionAiming for Relevance
Source quote
L156: 94 events over 45 patients with average length of 15 steps. The held-out RMSE over the entire signal for the baseline model is 1.205 while the corresponding RMSE of the Mixed model is only slight better at 1.167. However, the Mixed model had a greater advantage in RMSE taken only over the annotated events 1.276 compared to 1.485 for the baseline.
2024Baseline LSTM trained with square loss baseline non-standard sliceRMSE1.485Heart Rate Prediction · subset=clinician-annotated eventsAiming for Relevance
Source quote
L156: 94 events over 45 patients with average length of 15 steps. The held-out RMSE over the entire signal for the baseline model is 1.205 while the corresponding RMSE of the Mixed model is only slight better at 1.167. However, the Mixed model had a greater advantage in RMSE taken only over the annotated events 1.276 compared to 1.485 for the baseline.